1. Catalogs
  2. AMETEK Process Instruments
  3. 909 Hot Wet Single Gas Mass Flow CEM

909 Hot Wet Single Gas Mass Flow CEM

909 Hot Wet Single Gas Mass Flow CEM

909 Hot Wet Single Gas Mass Flow CEM

Product catalog summary
Key Benefits:
  • High reliability with reduced maintenance due to no moving parts.
  • Combines sample and mass flow measurement in one device.
  • Hot/Wet analysis eliminates the need for water compensation or correction factors.
  • Accuracy better than 2.5 ppm for SO2, with no interference from H2O or CO2.
  • Automated zero and span gas calibration included.
  • Incorporates flow measurements for emission rate calculations.
Applications:
  • Sulfur recovery incinerators.
  • Sulfuric acid plants.
Key Markets:
  • Gas processing sulfur recovery.
Product Overview:

The AMETEK 909 is a single gas continuous emissions monitoring (CEM) system designed for monitoring stack emissions on a mass rate basis. It measures stack effluent temperature and velocity, along with pollutant concentrations, enabling mass emission rates to be reported. An optional zirconium oxide (ZrO2) sensor allows for oxygen (O2) monitoring.

The system's components are heated above the dew points of all gases in the sample stream, ensuring accurate gas concentration calculations without the need for water removal or sample dilution. It features built-in zero and span calibration and four-zone temperature control.

Performance Specifications:
  • Methodology: Dual beam, high resolution, nondispersive UV.
  • Accuracy: Better than ±1% full scale of standard ranges.
  • Repeatability: Better than ±0.5% full scale of standard ranges.
  • Linearity: Better than ±1% of full scale.
  • Response time: Typically less than 30s to T90.
  • Sample transport: Air aspiration with a typical flow of 3 to 5 L/min.
  • Temperature control: Independent control of three zones.
  • Power: 120 VAC or 240 VAC, 600 W for analyzer only.
  • Communications: Analog and digital options with Modbus protocol.
  • Physical dimensions: 1117.6 x 1553.6 x 306 mm.
  • Weight: Estimated minimum 160 kg.
  • Approvals: NEC/CEC, ATEX, IECEx, GOST certifications.
Measurable Species:
  • SO2: 250 ppm to 100% full scale.
  • NO: 300 ppm to 100% full scale.
  • NO2: 300 ppm to 100% full scale.
  • H2S: 125 ppm to 100% full scale.
  • NH3: 125 ppm to 100% full scale.
  • Cl2: 500 ppm to 100% full scale.
See more

Catalog excerpts

909 Hot Wet Single Gas Mass Flow CEM-1

AMETEK' PROCESS INSTRUMENTS MEASURES: SO2/ NO, NO2 or H2S with mass flow PRODUCT DATA SHEET 909 Hot/Wet Single Gas Mass Flow CEM Specifically configured for monitoring stack emissions on a mass rate basis The AMETEK 909 is a single gas continuous emissions monitoring (CEM) system that measures stack effluent temperature and velocity, in addition to pollutant concentrations at stack conditions, enabling mass emission rates to be reported. With the addition of an optional zirconium oxide (ZrO2) sensor, the 909 is also capable of monitoring oxygen (O2). The sample cell and all components in contact with the sample are heated above the dew points of all gases in the sample stream. This results in a more accurate calculation of gas concentrations, compared to other CEM systems that require water removal or sample dilution. No corrections for condensed and dissolved components are required. It also results in a simpler, more reliable analytical system as there is no need for sample drying. The 909 has built-in zero and span calibration and four zone temperature control (sample line, probe, sample conditioning unit, and oven). Full function CEM As a full function CEM, the 909 performs all necessary sample gas and calibration gas flow management, as well as probe and sample line temperature control. Simply add a sample probe and sample line to be fully operational. Maximum reliability and durability With a no-moving-parts design, the 909 is built for maximum reliability and durability. It is a complete system with a sample extraction and transport system designed to ensure sample integrity. High resolution ultraviolet (UV) technology With a dual beam, dual wavelength configuration, a resolution of better than 0.02nm is provided by high-intensity line source lamps, enabling unparalleled linearity over a wide dynamic range, and leading to very accurate measurements. The dual beam configuration, combined with the reference measurement, ensures low noise performance with minimal baseline and span drift. • High reliability and reduced maintenance (no moving parts) • Sample and mass flow measurement in one device • Hot/Wet analysis - no water compensation or correction factors required • Accuracy better than 2.5 parts per million (ppm) SO2 • No water (H2O) or carbon dioxide (CO2) interference • Automated zero and span gas calibration • Incorporates flow measurements for emission rate calculations B5I APPLICATIONS • Sulfur recovery incinerators • Sulfuric acid plants • Gas processing sulfur recovery To find out more or request a quote visit our website AT ametekpi.com

 Open the catalog to page 1
909 Hot Wet Single Gas Mass Flow CEM-2

909 Hot/Wet Single Gas Mass Flow CEM PERFORMANCE SPECIFICATIONS © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0175 Rev 6 (0818) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice.