5800 Moisture Analyzer

5800 Moisture Analyzer

5800 Moisture Analyzer

Product catalog summary
Key Benefits
  • Most accurate trace moisture measurement technology available.
  • Fast response to changing moisture levels.
  • Specific to moisture in most applications.
Applications
  • High-purity gas production.
  • Olefin production, storage, and transmission.
  • Semiconductor gases.
Key Markets
  • Semiconductor manufacturing.
  • Industrial gas.
  • Petrochemical.
Performance Overview

The 5800 Moisture Analyzer offers high accuracy, multi-gas compatibility, fast response speed, and a wide measurement range, making it ideal for critical moisture measurement applications. It features a NIST-traceable internal moisture generator for performance verification and an alarm system for operational alerts.

Multi-Gas Compatibility

Compatible with non-corrosive gases including inerts (He, Ar, Ne, Xe, Kr), O2, H2, N2, NO, CO, hydrocarbons, air, and specialty gases like SF6. CO2 requires a custom measurement cell.

Fast Response Speed

Reaches 63% of a steady state reading in less than five minutes, outperforming other analyzers in the 0.1 to 100 ppmv range.

Wide Measurement Range

Measures from 0.02 ppmv to 1000 ppmv, with a calibrated range of 0.1 ppmv to 100 ppmv. Features two custom-settable 4-20 mA outputs.

Performance Specifications
  • Limit of detection: 0.02 ppmv.
  • Accuracy: ±20 ppbv or 5% of the reading.
  • Sensitivity: 5 ppbv or 0.5% of instrument range.
  • Response time: Less than five minutes for 63% of a step change.
  • Inlet pressure: 1 to 6.89 Bar (15 to 100 psig).
  • Sample flow: 600 ml/min at STP.
  • Sample gas temperature: 0 to 100°C (32 to 212°F).
  • Outputs: Digital display, two 4-20 mA analog outputs, RS485 serial port.
  • Alarms: Three independent contact closures for system alerts.
  • Environmental: 4 to 40°C, 90% relative humidity, non-condensing.
  • Utility requirements: 85 to 265 volts, 47 to 63 Hz.
  • Mounting options: Stand-alone or 19-inch rack installation.
  • Dimensions: 432 x 132 x 381 mm; Rack-mount height: 221 mm.
  • Net weight: 16.79 kg (37 lbs).
  • Approvals: NEC Class I, Division 2, Groups A, B, C, D; EU EN50081/82; EN61010-1.
See more

Catalog excerpts

5800 Moisture Analyzer-1

AMETEK* PROCESS INSTRUMENTS PRODUCT DATA SHEET 5800 Moisture Analyzer Excellent performance for critical moisture measurements For critical moisture measurement applications, the 5800 offers a combination of exceptional performance benefits: high accuracy, multi-gas compatibility, fast response speed, and wide measurement range. The 5800 is ideal for moisture applications that require accurate results. The NIST-traceable internal moisture generator allows the user to quickly confirm analytical performance, at any time, on the sample gas. The generator adds a known amount of moisture to conditioned gas. The resulting known wet gas is then directed to the analyzer's sensor, verifying proper sensor and system operation. An alarm contact alerts the operator if the analyzer fails this verification process. The verification sequence may be started on a programmed schedule or on demand. Multi-gas compatibility The 5800 is completely compatible with virtually all noncorrosive gases, including inerts - helium (He), argon (Ar), neon (Ne), xenon (Xe) and krypton (Kr) - oxygen (O2), hydrogen (H2), nitrogen (N2), nitric oxide (NO), carbon monoxide (CO), hydrocarbons, air, and many specialty gases such as sulfur hexafluoride (SF6). Changing gases is simple and quick. Fast response speed The 5800 reaches 63% of a steady state reading in less than five minutes, far faster than other moisture analyzers in the 0.1 to 100 parts per million by volume (ppmv) range. Because the analyzer employs unique non-equilibrium measurement techniques, it delivers this exceptional response during dry-down as well as when wetting-up. Wide measurement range The 5800 measures from 0.02 ppmv (20 parts per billion by volume (ppbv)) to 1000 ppmv. The calibrated range is 0.1 ppmv to 100 ppmv. Two custom-settable 4-20 mA outputs are provided, which may be assigned to cover any portion of the operating range. One analog output is auto-ranging, to maintain high output resolution over the widest measurement range possible. KEY BENEFITS • Most accurate trace moisture measurement technology available • Responds faster to both increasing and decreasing moisture levels • Specific to moisture in most applications APPLICATIONS • High-purity gas production • Olefin production, storage, and transmission • Semiconductor gases n KEY MARKETS • Semiconductor manufacturing • Industrial gas • Petrochemical

 Open the catalog to page 1
5800 Moisture Analyzer-2

PRODUCT DATA SHEET PERFORMANCE SPECIFICATIONS Compatible gases © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0130 Rev 5 (1018) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice.