Catalog excerpts
AMETEK PROCESS INSTRUMENTS PRODUCT DATA SHEET 303B Moisture Analyzer Highly accurate portable measurement of trace moisture in gas streams for Division 2 areas Based on Faraday's Laws of Electrolysis, the 303B absorbs and electrolyzes moisture down to fractional parts per million (ppm) and is linear to its 2000 parts per million by volume (ppmv) maximum reading. An electrolytic cell does not require calibration and is virtually specific to water, so it can be used to monitor the moisture content in nearly any background gas. Versatile The unit is compact, lightweight, and suitable for both portable use and permanent installation. The 303B is available with a choice of power sources covering AC, external DC, and internal battery operation. Fast, accurate measurement The 303B can be situated close to the sample tap, eliminating long tubing runs and reducing the sample transport time of the process gas which improves the overall measurement response time. The 303B transmits the moisture level to a recorder or control center via its 4-to-20 mA output. Built-in bypass flowmeter A built-in bypass flowmeter increases total sample flow to reduce response time. This bypass feature is valuable when the 303B is in portable service - for example, rapidly analyzing moisture in gas cylinders, where it is essential to purge valves, regulators, and tubing of atmospheric moisture prior to taking measurements. To find out more or request a quote visit our website ametekpi.com
Open the catalog to page 1PRODUCT DATA SHEET PERFORMANCE SPECIFICATIONS Dynamic range SALES, SERVICE & MANUFACTURING WORLDWIDE SALES AND SERVICE LOCATIONS Canada - Alberta 2876 Sunridge Way NE Calgary AB T1Y 7H9 Tel: +1 403 235 8400 Fax: +1 403 248 3550
Open the catalog to page 2All AMETEK Process Instruments catalogs and technical brochures
-
NATURAL GAS SOLUTIONS
11 Pages
-
Ranarex Gas Gravitometers
2 Pages
-
Dew Point Tester
2 Pages
-
MGB1000 Micro Gas Blender
2 Pages
-
Dymaxion Mass Spectrometer
4 Pages
-
Remote Calibration Unit
2 Pages
-
WDG-VRM Oxygen Analyzer
2 Pages
-
WDG-VCM Flue Gas Analyzer
2 Pages
-
TM2000 Oxygen Analyzer
2 Pages
-
HAG Sampling Probe
2 Pages
-
5100 CO2 Gas Analyzer Atex
2 Pages
-
932 Multi Gas Analyzer
2 Pages
-
919 Hot Wet Gas Analyzer
2 Pages
-
910 Hot Wet Multi Gas CEM
2 Pages
-
9900RM/9900WM Gas Analyzers
2 Pages
-
931 Single Gas Analyzer
2 Pages
-
920 Multi Gas Analyzer
2 Pages
-
934 Single-Gas Analyzer
2 Pages
-
Ranarex Gravitometer
2 Pages
-
Dew Point Testers
2 Pages
-
5920 UHP Moisture Analyzer
2 Pages
-
5910 UHP Moisture Analyzer
2 Pages
-
5830 Moisture Analyzer
2 Pages
-
5812 Moisture Analyzer
2 Pages
-
5800 Moisture Analyzer
2 Pages
-
2850 Moisture Analyzer
2 Pages
-
5100 CO2 Gas Analyzer
2 Pages
-
5000 Sample System
2 Pages
-
5000 Analyzer Controller
2 Pages
-
5000 Moisture Analyzer
2 Pages
-
3050-TE Moisture Analyzer
2 Pages
-
3050-AP Moisture Analyzer
2 Pages
-
3050-AM Moisture Analyzer
2 Pages
-
WDG 1200 1210 Insitu
2 Pages
-
CEM O2 TM
2 Pages
-
CEM Humox
2 Pages
-
TM2000 Trace Oxygen Analyzer
2 Pages
-
CEM O2 Analyzer
2 Pages
-
WDG-HPIIC
2 Pages
-
CG1000
2 Pages
-
CMFA-P 2000
2 Pages
-
ta5000 Gas Analyzers
2 Pages
-
ta3000 Gas Analyzers
2 Pages