AMETEK i PROCESS INSTRUMENTS A PRODUCT DATA SHEET MEASURES: Hydrocarbon Dew Point Temperature To find out more or request a quote visit our website 241CE II Hydrocarbon Dew Point Analyzer Accurate, reliable hydrocarbon dew point measurement Natural gas producers, distributors, and industrial consumers understand the importance of ensuring that natural gas meets strict quality specifications which typically include a maximum hydrocarbon dew point temperature. Even relatively small quantities of liquids in natural gas transmission lines can damage sensitive metering equipment, plug lines, interfere with odorants, and most importantly, create unsafe conditions. The 241CE II Hydrocarbon Dew Point Analyzer uses a thermoelectric cooler to control the temperature of a two-surface mirror. The mirror's temperature is measured using a platinum resistance temperature detector (RTD) which provides better long-term stability and accuracy versus thermocouples. Combing sensitive optics with a precisely controlled cooling rate, the 241CE II delivers improved accuracy and repeatability compared to a manual chilled mirror device. In many applications, automated, on-line analyzers for the measurement of hydrocarbon dew point are replacing manual chilled mirrors, which require a trained operator, or calculation methods using a gas chromatograph, which can be susceptible to large errors in the determination of hydrocarbon dew point. Turnkey installation A fully integrated sample system package, including proprietary multiple stage filtration specifically designed for natural gas samples, protects the analyzer from common natural gas contaminants. Reliable operation The single-cell, dual-surface mirror design eliminates interferences, allowing the 241CE II to differentiate between water and hydrocarbon condensate, ensuring an accurate measurement of the hydrocarbon dewpoint. Automated measurement The 241CE II uses a three-stage measurement process that requires no tuning, no adjustments and no need for external coolant. The optical measurement of hydrocarbon dew point temperature eliminates any errors due to operator interpretation of the condensate formed on the mirror. Hkey benefits • Accurate and objective direct measurement of hydrocarbon dew point temperature at pipeline or cricondentherm pressure • Proprietary three-stage sample filter provides superior protection • Designed for unattended operation with low maintenance • Electricity is the only consumable • Digital communications via Modbus RTU protocol • Optional remote start of measuring cycle available via external input • Can be combined with AMETEK's quartz crystal microbalance (QCM) moisture measurement in a single package PTl KEY MARKETS • Natural gas • Power • Chemical and petrochemical • Refining S3 APPLICATIONS • Natural gas custody transfer stations, pipelines, underground storage, blending control • Monitor amount of superheat in gas turbine feed gas • Optimizing of switch times for pressure swing absorptio

Open the catalog to page 1
241 CE II Hydrocarbon Dew Point Analyzer - 2

PERFORMANCE SPECIFICATIONS © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0173 Rev 6 (0818) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice.

Open the catalog to page 2

All AMETEK Process Instruments catalogs and technical brochures

  1. CEM O2 TM

    2 Pages

  2. CEM Humox

    2 Pages

  3. WDG-HPIIC

    2 Pages

  4. CG1000

    2 Pages

  5. CMFA-P 2000

    2 Pages