Data Sheet Model IDT - For Hazardous Area Applications INTRINSICALLY SAFE PRESSURE TRANSMITTERS DESCRIPTION The Model IDT intrinsically safe pressure transmitters are specifically designed for use in hazardous area pressure measurement applications that require a compact design. • Compact rugged design for tough applications. Intrinsically safe approvals for the IDT includes FM US and FM Canada (cFMus), ATEX and IECEx for worldwide users’ pressure measurement requirements. The IDT offers premium performance and versatility of use for many applications including upstream oil and gas, general industrial end users, and OEMs. The IDT offers precision accuracy at +/-0.2% FS (BFSL) typical. The design incorporates a stainless steel isolation diaphragm and 316 stainless steel construction for use with most media types. The IDT is offered in pressure ranges from full vacuum to 5000 psig and 15 psia through 300 psia. The transducer also accepts both regulated and unregulated excitation voltages and provides output signals such as 1-5 VDC, 1-6 VDC, 0-5 VDC, 0.5 to 4.5VDC and 4-20 mA. The IDT transducer is manufactured in the United States under ISO 9001:2008 and meets ARRA. • All 316 Stainless Steel Construction and Wetted Materials- Resists the corrosive effects of caustic medias or wash downs and is compatible with a variety of media. • Hastelloy diaphragm for Hydrogen Sulfide H2S applications. Monel is also available. • 0.2% Typical Accuracy- Offers superior accuracy to competitive models and can be used on critical applications. • Factory Calibrated for Pressure and Temperature-No need for field calibration. Plug and Play reliability. • Wide Pressure Ranges and Types (PSIG,PSIA,PSIS, Compound)- Can be used in a variety of applications. • RFI/EMI Protection-For use in high noise environments -EN 61326-1 • Transient / Burst / Surge Protection - EN61326-1 Secondary protection available with Model LMA912 • Reverse Polarity Protection- Installation safety and not damaged by reverse wiring. • Numerous Electrical Outputs and ConnectionsAllows quick hook-up and use with standard process equipment, conventional receivers, and compatible with microprocessors. • Low Power Voltage Output- Allows for solar and battery operation and longer life. • Custom Designs Available- OEM oriented to special needs. Please call 215-354-1832 or Email: mctpmt.sales@ametek.com Model IDT Pressure Transducer On-line order fax: +1 215-354-1802 or e-mail: mctpmt.sales@ametek.com Sales/Technical Support: +1 215-355-6900 | 820 Pennsylvania Blvd | Feasterville PA 19053 U.S.A. © AMETEK, Inc. All rights reserved. Printed in the U.S.A. IDT Datasheet - K796502 - Issue #1 Specifications are subject to change without notice. Visit our Web site for the most up-to-date informa

Open the catalog to page 1
Model IDT - 2

Data Sheet Model IDT - I.S. Pressure Transmitter Specification Pressure Ranges - Reference Chart Below Consult Factory for Non Standard Ranges VACUUM Up to 5000 psi PSIG, PSIS, and PSIA Available Accuracy @25°C Including Linearity (BFSL) Hysteresis & Repeatability Load Limitation 10K Ohms MIN (All Voltage Outputs) Pressure Response Time (Voltage) Power On Response Time (Voltage) Power (Voltage) Total Error Band (Includes Temperature Effects, Zero & Span Set) Process Wetted Material Electrical Housing Material Diaphragm Material 316 Stainless Steel (Standard): Hastelloy or Monel Options...

Open the catalog to page 2
Model IDT - 3

Data Sheet Model IDT - I.S. Pressure Transmitter WIRING DIAGRAM Common For DIN Connectors (FM Approval Pending) SERVED AND NEITHER THIS DRAWING DRAWINGDRAWING NOR ANY INFORMATION IT .TS ARE RESERVEDRESERVED ANDTHIS NORTHIS INFORMATION IT ALL RIGHTS ARE AND NEITHER NEITHER ANY NOR ANY INFORMATION IT , OR USED WITHOUT WRITTEN PERMISSION FROM AMETEK INC. FROM AMETEK INC. CLOSED TOOR USED WITHOUT WITHOUT PERMISSION FROM AMETEK INC. O OTHERS, OTHERS, OR USED WRITTEN WRITTEN PERMISSION WORKMANSHIP ARE DEFINED IN MS-645-A. EPTABLE WORKMANSHIP ARE DEFINED IN MS-645-A. HIP ARE DEFINED IN MS-645-A....

Open the catalog to page 3
Model IDT - 4

Data Sheet Model IDT - I.S. Pressure Transmitter MODEL NUMBERING Transmitter Type D Digitally compensated pressure transmitter for hazardous use Protection Type and Temperature code D2 Division 2, Zone 2, potted electronics Division 2, Zone 2, conformal coated electronics Division 1, Zone 0, Intrinsically safe, potted electronics Division 1, Zone 0, Intrinsically safe, conformal coated electronics Factory Selected Electrical Connector FM Approved Industrial • Division and Zone Safety Approval • Protection IP/ Type HM2 1/2 NPT male with 24AWG cable • Div 1, Zone 0 Div 2, Zone 2 • IP67, Type...

Open the catalog to page 4
Model IDT - 5

Data Sheet Model IDT - I.S. Pressure Transmitter MODEL NUMBERING (CONTINUED) Factory Selected X Factory Selected Other optional process connectors Silicone (Standard) Additional fills (Contact Customer Service) Stainless steel (Standard) Additional diaphragms (Contact Customer Service) Compound (-14.7psi to full scale) Compound equal (minus pressure equals positive pressure. Ex: 15 to 0 to 5psi) Static (sealed sensor, no atmospheric reference) Other pressure types (Contact Customer Service) Pressure Range xxxxx Custom Options XXXX Safety/Approval Fields Additional Ametek options, or...

Open the catalog to page 5

All AMETEK PMT Products catalogs and technical brochures

  1. 1981

    4 Pages

  2. Model IPS

    4 Pages

  3. Model 40

    9 Pages

  4. Model 742

    2 Pages

  5. Model 742 D

    3 Pages

  6. Model 89

    2 Pages

  7. Model 89D

    2 Pages

  8. Model-DCT

    5 Pages

  9. Model 88C

    3 Pages

  10. PMT LMA

    3 Pages

  11. L serie

    2 Pages

  12. Model LMA

    3 Pages

  13. ECPT10

    2 Pages

  14. PST360

    2 Pages

  15. Model 656

    5 Pages

  16. 1535 Gauge

    2 Pages

Archived catalogs