HMV-G Series Microhardness Testing System
14Pages

{{requestButtons}}

Catalog excerpts

HMV-G Series Microhardness Testing System - 1

~S""'IMADZU Excellence in Science Micro Vickers Hardness Tester

Open the catalog to page 1
HMV-G Series Microhardness Testing System - 2

hardness testing Hardness Testers Featuring Automatic

Open the catalog to page 2
HMV-G Series Microhardness Testing System - 3

In recent years, instruments have been increasingly used by inexperienced operators. At the same time, reliable measurements are essential in order to ensure quality, so instruments are needed that can be used easily by anyone, with no risk of human measurement error. Our Micro Vickers Hardness Testers, featuring automatic length measurement, have been standardized as a response to such demands. I Standardized automatic length measurement function using a CCD camera built in a novel G frame (G21 series) The automatic risk of human error. The adoption improves lens switching match the size...

Open the catalog to page 3
HMV-G Series Microhardness Testing System - 4

Leave Everything to the HMV-G Series — Do you have any of the following problems? — Surface Processing and Etching Fields Lead Frames.; solar cell Field Solar Cells I There is a shortage of trained users, and the data varies significantly depending on the analyst. I There are scratches on the surfaces of lead frames and mechanical parts, so measuring indentation lengths is difficult. Statistical processing should be performed to evaluate quality stability, but there are not enough personnel The goal is to measure a range of samples, even those with unknown hardness levels. The goal is to...

Open the catalog to page 4
HMV-G Series Microhardness Testing System - 5

For example ... I The goal is to evaluate the hardness gears and other parts with those used in automobiles, equipment, difficult. ~ The goal is to measure the depth of hardening heat treatment, calculations point positioning I There are many test points, For example ... " The goal is to measure the hardness other long samples, because the instrument I don't want Measuring cannot accommodate samples for the first time is problematic, because neither optimal Micro Vickers Hardness Tester

Open the catalog to page 5
HMV-G Series Microhardness Testing System - 6

Leave Everything - Solve your Even scratched reading function that adopts good I User-friendly software allows all the information to be seen at a glance.This improves operational efficiency and eliminates errors. I Equipped with a smart, compact built-in CCO camera mechanism. The instrument can be installed neatly and simply, with no need for wiring function, the data can be assessed in chronological order. The stability of the testing system can be evaluated using statistical methods, which means the instrument can be used effectively for obtaining ISO 170252) and ISO 169492)...

Open the catalog to page 6
HMV-G Series Microhardness Testing System - 7

A stage viewer function allows the user to observe the total image of the sample for specifying arbitrary positions. It is easy to test a desired position. Furthermore, an automatic sample shape recognition function detects the edges of the sample so test positions can be configured easily along the sample edges. An Excel compatible programming function has been adopted. Test patterns can be programmed with an office Pc. The test force can be set for individual the size of the indentation points in a test pattern. can be arranged even if the hardness The test force can be configured an open...

Open the catalog to page 7
HMV-G Series Microhardness Testing System - 8

G Frame A stable frame that isdevoid of angles, has a graceful style, and disperses test loads uniformly has been adopted. The inner direction has been expanded to increase the workspace, which improves both efficiency and operability. Even large samples can be accommodated. Low Test Force (Optional) Tests can be performed at arbitrary in the range from 1 gf to 2 kgf. @) Electromagnetic Force Control The center of the G frame is open, so long and narrow samples can now betested as is (design registration canbe configured @ Fracture Toughness Measurements The system measures the lengths of...

Open the catalog to page 8
HMV-G Series Microhardness Testing System - 9

@ Stage Viewer Search the stage, and overlap the image data to create a total image. @ Simple Test Mode Connect a USB memory stick to the instrument to automatically save data in CSV format Also, the stage can be moved to the measurement position from the total image obtained. @ Sleep Mode @ Automatic Sample Shape Recognition Excel data. As a result, programs can be installing special Angular adjustments to suit the sample orientation are made easily while observing the actual sample. not in use to conserve the amount of power used. The coordinates of test positions are set using created on...

Open the catalog to page 9
HMV-G Series Microhardness Testing System - 10

H MV-G Series Test Software Simple Test Operations The sequence of primary operations anyone can use the instrument from setting conditions for ease of visual tracking, In simplemode,testscan be performedby setting the test forceand duration time. The objective lenses and indenters can be switched with a single click:' with a single click:' Each function is easily accessed with large icons. Sample surface conditions (cylindrical or spherical) are easily set. easy. makes read, then makes image results are simultaneously displayed. and the indentation easily before TheInstrument switches...

Open the catalog to page 10
HMV-G Series Microhardness Testing System - 11

Sample Applications Testing The system detects the gear edges Gears Measurement of Depth and measures of Hardening the hardness inside the gear. Also, the test force can be changed for each test position. (patent pending) r.oJ----+, --+--+-+--+--+---+-----t-- Cross section Touch Panel Operator A color touch panel has been adopted, making it easy to set conditions, measure indentation lengths, and display results. ~ Test force Simple test Test mode Test condition setting assist Test force: Test Force In standard test mode, tests canbe performed by setting detailed conditions such as sample...

Open the catalog to page 11
HMV-G Series Microhardness Testing System - 12

Operation Method Maximum Number of Indenters Attached Maximum Number of Objective LensesAttached Vickers indenter Vickers indenter Standard Objective Lenses Provided Electric Turret Function" Vickers indenter Standard Indenters Provided Test Force Nine force types: 98.07 mN, 245.2 mN, 490.3 mN, 980.7 mN, 1.961 N, 2.942 N, (When low test force option is applied) Test Force Accuracy Loading Unit Test Force Duration Time Indentation Reading Method Automatic reading from analysis of a digital image from the built-in CCD camera, or by manually setting Eyepiece Image capture by the built-in CCD...

Open the catalog to page 12