1. Catalogs
  2. AMETEK MOCON
  3. Dansensor MultiCheck 2 Data Sheet
video corpo

Dansensor MultiCheck 2 Data Sheet

Dansensor MultiCheck 2 Data Sheet

Dansensor MultiCheck 2 Data Sheet

Product catalog summary
Overview
The Dansensor® MultiCheck® 2 is an all-in-one system combining a headspace gas analyzer, leak detector, and valve tester to enhance the quality control of Modified Atmosphere Packaging (MAP) processes. It is designed to increase packaging line uptime and reduce troubleshooting time, ensuring product integrity and brand reputation.
Key Benefits
  • Comprehensive MAP quality control.
  • Protection of brand and product integrity.
  • Maximized uptime with fast and reliable testing.
  • User-friendly interface and operation.
  • 50% faster than previous models.
  • Reduced human error and improved traceability.
Features
  • Four-in-one testing: headspace, leak, valve leak, and valve release.
  • Oxygen headspace measurements.
  • Optional degassing valve test unit (VTU).
  • Easy maintenance with self-rinse program and replaceable filters.
  • Intuitive touchscreen interface with individual user logins.
  • Data storage and real-time data transfer capabilities.
  • USB connectivity for barcode scanner, keyboard, or printer.
  • Compliance with ASTM F2095 standards.
Operation Procedure
  1. Place a septum on the package and seal any degassing valve with tape.
  2. Insert the test head through the septum and initiate the test for headspace analysis and leak detection.
  3. Optionally, test the degassing valve using the VTU.
  4. Automatically store and export test results via USB or real-time data transfer.
Technical Specifications
  • Test Types: Headspace gas analysis, leak detection, optional valve tests.
  • Typical Test Time: 60-90 seconds.
  • Applications: Suitable for most MAP applications, including coffee bags.
  • Package Size: Up to 5 liters.
  • Measurement Accuracy: ±0.25% O2, ±0.5 mbar for low range, ±5 mbar for high range.
  • Data Capacity: Over 100,000 tests.
  • Dimensions: Instrument - 304 x 236.5 x 185 mm; Stand + test head - 250 x 330 x 410 mm.
  • Power Supply: External PSU, 100-240 VAC.
  • Compliance: ASTM F2095, ISO 11607.
See more

Catalog excerpts

Dansensor MultiCheck 2 Data Sheet-1

RELIABLE ALL-IN-ONE LEAK AND HEADSPACE TESTING SYSTEM DATA SHEET Benefits • Complete MAP quality control • Protect your brand and product • Maximize uptime with quick and reliable package testing • Easy to use • All-in-one integrated solution 50% faster than previous models • Reduce time troubleshooting issues and risk of human error Dansensor MultiCheck 2 with VTU for complete package testing Fast and reliable combined headspace and leak testing By combining a headspace gas analyzer, leak detector and valve tester in one unit, the Dansensor® MultiCheck® 2 helps you achieve fast, consistent, and reliable quality control of your MAP packaging process. Increase the uptime of your packaging line and avoid time consuming troubleshooting exercises. Equipped with specialized filters and sensors for applications like coffee, it ensures the integrity of your MAP packaging, preserving your product’s flavor and aroma and your brand’s reputation. In addition, you reduce the risk of human error and improve traceability with dependable data capture and real time data transfer. With the ability to conduct four tests in one – headspace gas analysis, leak detection, valve leak and valve release – the Dansensor MultiCheck 2 is 50% faster, takes up less space, and is more user friendly than its predecessors. The Dansensor MultiCheck 2 is designed for easy maintenance with a self-rinse program and replaceable filters, to preserve the accuracy of your measurements and ensure uptime. Features • Four tests in one: headspace, leak, valve leak and valve release • O2 headspace measurements • Optional degassing valve test unit (VTU) • Test head with integrated sense probe • Easy maintenance and cleaning • Touchscreen with intuitive interface • Individual user logins • Store test settings for repeatability • Data storage and real time data transfer • USB port for connecting optional barcode scanner, keyboa

 Open the catalog to page 1
Dansensor MultiCheck 2 Data Sheet-2

DATA SHEET 1. Place a septum on the package and, if the package has a degassing valve, seal the valve with tape. 2. Insert the test head through the septum and start the test. The instrument conducts headspace analysis, followed by a leak test. 3. (optional) Cut the degassing valve out of the package and insert it into the valve testing unit (VTU). Close the VTU and start the valve test. 4. The test results are automatically stored in the unit and can be exported to a USB flashdrive or real time data transfer. Technical Specifications Specifications Test types Typical test time Heating time (max)...

 Open the catalog to page 2

All AMETEK MOCON catalogs and technical brochures

  1. AQUATRAN 3/40

    4  Pages

  2. BevAlert®

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.