1. Catalogs
  2. AMETEK MOCON
  3. Dansensor CheckPoint 3 Headspace Analyzer
video corpo

Dansensor CheckPoint 3 Headspace Analyzer

Dansensor CheckPoint 3 Headspace Analyzer

Dansensor CheckPoint 3 Headspace Analyzer

Product catalog summary
Overview: The document provides detailed information about the CheckPoint 3, a portable gas analyzer designed for quality control of Modified Atmosphere Packages (MAP). It highlights the benefits, features, technical specifications, and operational procedures of the device.
Benefits:
  • No need for PC software, enhancing ease of use.
  • Improves MAP quality control and process efficiency.
  • Offers greater business transparency and secures brand reputation.
  • Provides a high level of portable analysis with low ownership costs.
  • Eliminates the need for daily 20.9% calibration.
Features:
  • Equipped with a new ceramic solid-state O2 sensor.
  • Capable of measuring O2 or combined O2/CO2 levels.
  • Includes a gas flow alarm and WiFi data transfer capabilities.
  • Features a fast processing system and a 3.5” color touchscreen.
  • Utilizes standard, low-cost needles with optional stainless steel needles.
  • Offers a data package capable of storing up to 1 million data logs.
  • Comes with a 2-3 year warranty on the sensor and a protective cover.
  • Supports multiple languages and provides graphic statistics.
Technical Specifications:
  • Available configurations include O2 and O2 & CO2 sensors.
  • Sample volume is 5 ml with a sample time of 9 seconds.
  • Measuring range is 0-85% for O2 and 0-100% for CO2.
  • Resolution is 0.1% for both oxygen and carbon dioxide.
  • Sensor accuracy is better than ± 0.1% or ± 2% of readout for O2 and ± 2% for CO2.
  • Device dimensions are 75 x 100 x 175 mm, weighing 0.7 kg.
  • Battery-powered with a recharge time of up to 5 hours, ready for 2,000 measurements.
  • Includes WiFi connectivity and a 12-month calibration and service period.
  • Expected sensor lifetime is over 3 years for O2 and over 5 years for CO2.
  • Compatible with RoHS, China RoHS, and CE standards.
Operational Procedure:
  1. Insert the needle into the package through the septum and start the test with one touch.
  2. The sensor draws a sample and displays O2 and CO2 levels within seconds.
  3. Results can be collected manually or automatically and transferred via WiFi.
  4. The web interface provides statistical data for documentation purposes.
Model Overview: The CheckPoint 3 is available in different models, including the standard, premium, and premium with data pack, each offering varying levels of user setup, warranty, and data handling capabilities.
See more

Catalog excerpts

Dansensor CheckPoint 3 Headspace Analyzer-1

DATA SHEET Benefits • No PC software required • Easy to use • Improves MAP quality control • Better process efficiency • Greater business transparency • Secures your brand's reputation • Highest level of portable analyzer • Low cost of ownership • No daily 20.9% calibration Checkpoint 3 -Innovative sensor technology Portable gas analyzer for quality control of Modified Atmosphere Packages (MAP) The new Checkpoint 3 is the most advanced portable gas analyzer on the market, enabling you to quickly and easily check for O2 and CO2 levels in Modified Atmosphere Packages (MAP) of any shape and size. With the new long-lasting sensor, the CheckPoint 3 delivers the highest level of accuracy on portable analyzers, making the packaging process more reliable. WiFi connectivity ensures a new unique user experience. With the web interface fast, easy and reliable data management is guaranteed. The high quality color screen combined with intuitive interface give a clear process overview and extremely easy testing traceability and transparency. CheckPoint 3 is perfect for productions looking for portability, best accuracy and just as important, a low cost of ownership. Features • NEW Ceramic solid state O2 sensor • O2 or combined O2/CO2 measurements • Gas flow alarm • Data collection/transfer via WiFi • Fast processing • Easy-to-read 3.5” color touchscreen • Uses standard, low-cost needles • Optional stainless steel needles • Data package, 1 million data logs • 2-3 years warranty on sensor • Protection cover • Multiple languages • Graphic statistics

 Open the catalog to page 1
Dansensor CheckPoint 3 Headspace Analyzer-2

DATA SHEET Samples are taken with easy replaceable and low-cost needles HOW DOES IT WORK? 1: Insert needle into the package through the septum. Start test with one touch button. 2: A sample will be drawn into the sensor. A few seconds later the CheckPoint 3 will tell you the O2 and CO2 level inside the package. 3: Result can be collected manually or automatically. Stored data can be transferred via WiFi to your company database. 4: The web interface provides statistic data for various documentation purposes. Checkpoint 3 Model Overview Note: No upgrade possible from CheckPoint 3 Premium to CheckPoint...