1. Catalogs
  2. AMETEK Dynamic Fluid Solutions
  3. Windjammer Brushless Blowers

Windjammer Brushless Blowers

Windjammer Brushless Blowers
1 / 136 PagesView full catalog

Windjammer Brushless Blowers

Product catalog summary
Overview: The document provides comprehensive technical specifications and performance data for AMETEK's Brushless DC Blowers, Fans, and Pumps. It categorizes products into low and high voltage blowers, variable speed blowers, impeller-style blowers, and includes information on controllers and application basics.
Low Voltage Brushless DC Blowers: Designed for applications requiring variable output for vacuum or pressure needs, these blowers feature brushless DC motor drives and high-efficiency fan systems. They are not suitable for life-sustaining applications or use with flammable gases. Output pressures reach up to 97.7” H2O and flows up to 160.3 CFM.
High Voltage Brushless DC Blowers: These models offer higher output pressures up to 169” H2O and flows up to 1100 CFM, suitable for demanding applications, and include IntelliGen technology for enhanced performance.
Variable Speed Blowers: The Nautilair series includes variable speed blowers with different input voltages and outputs, designed for precise airflow and pressure control.
Brushless DC Fans and Impeller-Style Blowers: Covers various models, highlighting voltage requirements and applications.
Pumps: Lists seal-less pumps with brush and brushless motors, detailing capacities from 10 to 26 gallons.
Controllers: A 5 Amp BLDC Blower Controller is essential for operating the brushless DC blowers.
Blower Application Basics: Provides guidelines for selecting and using blowers, emphasizing not exceeding operational limits and ensuring proper alignment and environmental conditions.
Key Considerations: AMETEK products are not designed for medical life support applications and should not be used beyond factory-specified limits. Performance may vary based on the operating environment.
General Information: AMETEK Windjammer Low Voltage Brushless DC blowers are designed for applications with power supplies of 72 VDC or less, requiring an electronic controller for operation.
Speed Control: Blower speed can be modulated using potentiometer adjustment or an analog speed command signal. Some models allow calibration within a 0-10V range.
Tachometer Output: A square wave output proportional to blower speed is standard in some models.
External Controllers: All models can be configured to operate with external controllers.
Model Specific Features: Various models offer features like inlet tubes, external balancing disks, and specific configurations for different voltages.
Protection Features: Include locked rotor and thermal protection in some models, with recommendations for circuit protection where needed.
Performance and Specifications: Detailed for various models, including operating voltages, temperature ranges, and customized performance options.
Specifications: Outlines specifications for various models, including voltage inputs, maximum sealed pressure, and maximum open flow rate.
Procedures: Instructions for proper polarity in power connections and availability of customized performance upon request.
Norms and Recommendations: Advises including a fuse for circuit protection and emphasizes not using products in medical life support applications.
Flow Configurations: Describes Bypass and Thru Flow configurations for certain models.
Performance Data: Presented for various models, indicating typical performance under controlled conditions.
Additional Features: Optional features include tachometer output and motor configuration with external controller connections.
Contact Information: For specific applications or custom solutions, contact AMETEK Technical & Industrial Products Sales department.
See more

Catalog excerpts

Windjammer Brushless Blowers-1

PRODUCT CATALOG \METEK PRECISION MOTION CONTROL BLOWERS WE’RE BIG ON BRUSHLESS WELCOME TO SOLUTION CITY®

 Open the catalog to page 1
Windjammer Brushless Blowers-2

A: Low Voltage Brushless DC Blowers 3.0" (76mm) BLDC Low-Voltage Blower A1 12/24 VDC Input, High Output 3.3" (84mm) BLDC Low-Voltage Blower A5 12/24 VDC, Standard Flow System 5.0" (127mm) BLDC Low-Voltage Blower A11 12/24 VDC, High Flow System 5.1" (130mm) BLDC Low-Voltage Blower A13 24 VDC Input, Standard Flow System 5.7" (145mm) BLDC Bypass Blower A17 24 VDC Input, High Flow System 5.7" (145mm) BLDC Thru Flow Blower A19 24 VDC Input, Standard Flow System 5.7" (145mm) BLDC Thru Flow Blower A21 24 VDC Input, High Flow System 5.7" (145mm) BLDC Bypass Blower A23 48 VDC Input,...

 Open the catalog to page 2
Windjammer Brushless Blowers-4

Low Voltage Brushless DC Blowers Low Voltage Brushless DC Blowers offer variable output for a wide range of vacuum or pressure applications. Standard blower designs offer brushless DC motor drives coupled to high efficiency fan systems in compact, cost effective packages. Standard models are available in a wide range of input voltages. AMETEK Brushless DC Blowers are not designed for, and should not be used in, life sustaining applications. AMETEK Brushless DC Blowers are not 100% sealed and therefore should not be used with flammable or hazardous gases. Blower Selection Blower Selection offers...

 Open the catalog to page 4
Windjammer Brushless Blowers-5

Low Voltage Brushless DC BlowersGeneral Information AMETEK Windjammer Low Voltage Brushless DC blowers offer a wide range of performance for applications with power supplies of 72 VDC and less. The following pages detail each model family, including performance, size, and input voltage. All brushless DC blowers require an electronic controller for operation. Most of the model families herein are offered with an onboard controller, and there are features and/or options available for customization. Speed Control: Among the low voltage model families there are several methods for modulating blower...

 Open the catalog to page 5
Windjammer Brushless Blowers-6

Low Voltage Brushless DC Blowers General Information 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package size but has a narrower range of operation due to thermal limitations of the motor and controller. Locked-Rotor and Thermal Protection: 5.7 inch Windjammers All models include locked rotor and thermal protection...

 Open the catalog to page 6
Windjammer Brushless Blowers-7

Low Voltage Brushless DC Blowers General Information 3.0" (76mm) BLDC Low-Voltage Blower 12/24 VDC 3.42 #20 AWG LEADS 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or [86.8] Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air 2.00 passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package Ø.63 [50.8] size but has a narrower range of operation due to thermal limitations of the motor and controller. [Ø16.0] DISCHARGE...

 Open the catalog to page 7
Windjammer Brushless Blowers-8

Low Voltage Brushless DC Blowers General Information 3.0" (76mm) BLDC Low-Voltage Blower 12/24 VDC 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or Typical Performance Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package size but has a narrower range of operation due to thermal limitations of the motor and controller. Flow (m3/hr) 0 5.7 inch Windjammers All...

 Open the catalog to page 8
Windjammer Brushless Blowers-9

Low Voltage Brushless DC Blowers General Information 3.0 (76mm) BLDC Low-Voltage Blower 12/24 VDC Input, High Output 3.06 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or [77,7] Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air 1.62 passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package [41,2] size but has a narrower range of operation due to thermalØ.56 limitations of the motor and controller. [9,7] Locked-Rotor...

 Open the catalog to page 9
Windjammer Brushless Blowers-10

Low Voltage Brushless DC Blowers General Information 3.0 (76mm) BLDC Low-Voltage Blower 12/24 VDC Input, High Output 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or Typical Performance Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package Flow (m3/hr) size but has a narrower range of operation due to thermal limitations of the motor and controller. 0 5.7...

 Open the catalog to page 10
Windjammer Brushless Blowers-11

Low Voltage Brushless DC Blowers General Information 3.3" (84mm) BLDC Low-Voltage Blower 12/24 VDC 4.42 [112.2] 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or Thru Flow. The Bypass configuration separates the motor and controller from the working air, #20 AWG LEADS working air whereas the 2.87 .78 [72.8] passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package [19.8] DISCHARGE size but has a narrower range of operation due to thermal limitations of the motor and controller....

 Open the catalog to page 11
Windjammer Brushless Blowers-12

Low Voltage Brushless DC Blowers General Information 3.3" (84mm) BLDC Low-Voltage Blower 12/24 VDC 5.7 Bypass or Thru Flow: The 5.7 inch Windjammer product family offers two flow path configurations: Bypass or Typical Performance Thru Flow. The Bypass configuration separates the motor and controller from the working air, whereas the working air passes over the motor and controller in a Thru Flow configuration. The Thru Flow configuration shortens the package size but has a narrower range of operation due to thermal limitations of the motor and controller. Flow (m3/hr) 0 30 Locked-Rotor and Thermal...

 Open the catalog to page 12

All AMETEK Dynamic Fluid Solutions catalogs and technical brochures

  1. ROTRON TDS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.