1. Catalogs
  2. AMETEK Drexelbrook
  3. SXRLTX Series, Floating Roof Tanks

SXRLTX Series, Floating Roof Tanks

SXRLTX Series, Floating Roof Tanks

SXRLTX Series, Floating Roof Tanks

Product catalog summary
IntelliPoint™ System Overview: The document outlines the IntelliPoint™ system, which is engineered for level measurement in floating roof tanks. It emphasizes the system's advanced features, safety mechanisms, and adherence to industry standards.
Key Features:
  • No need for calibration or setpoint adjustments.
  • Automatically ignores coatings to prevent false alarms.
  • Continuous self-testing of circuits and sensing elements for faults.
  • Remote or integral electronics with dual compartment housing to separate customer wiring from sensing elements.
Testing and Verification:
  • Auto Verify™: A continuous self-test feature that ensures the integrity of electronics, sensing elements, and cables, alerting personnel to any faults.
  • Manual Certify™: Allows for manual testing of the system without sensor removal, ensuring proper connection and functionality.
Specifications:
  • Adjustable lengths from 1' to 18' (0.3 to 5.48 m).
  • Wetted parts include 316SS, FEP insulated flexible cable, and non-sparking brass sensor.
  • Complies with API 2350 regulations and is suitable for safety-related systems with SIL2 (SIL3 with redundant switch) compliance.
Technical Specifications:
  • Technology: RF Admittance.
  • No calibration required.
  • High Level Fail Safe operation mode.
  • Repeatability: 2 mm (0.08 inch) for conductive liquids.
  • Response Time: Less than one second.
  • Temperature Range: Ambient -30 to 70°C, Storage -40 to 85°C.
  • Power Supply: 13-30 Vdc, 2 watts maximum consumption.
  • Output: Various mA settings for alarm, normal, and fault states.
  • Ingress Protection: IP66 NEMA 4, 4X.
  • FM approved for various hazardous locations.
Applications: Specifically designed for floating roof tanks with flexible sensing elements, suitable for both internal and external roofs, adaptable to various tank applications.
Safety and Compliance: Tested for functional safety and conforms to SIL, FMEDA requirements, ensuring reliability and safety in hazardous environments.
Sensing Elements and Mounting Options: The document details various sensing elements and mounting options for industrial applications, including pressure and temperature ratings, materials, and specific applications.
Specifications: Lists sensing elements with pressure and temperature capabilities, such as general-purpose sensors rated at 13.8 bar at 232°C and high-pressure sensors up to 275.8 bar at 316°C. Materials include 316SS, PEEK, TFE, and Hastelloy C.
Applications: Designed for general-purpose use, corrosive materials, sanitary conditions, and high-pressure/high-temperature environments, including fly ash precipitators and hopper installations.
Mounting Options: Includes NPT threads, sanitary TriClamps, and ANSI/DIN flanges, each with specific materials and pressure ratings.
Electronics and Output: Sensors available with integral or remote electronics, various cable lengths and types, output options include 8-16 mA and SPDT relays for safety and alarm functions.
Key Notes: Emphasizes selecting the correct mounting option and ensuring the Cote-Shield Length (CSL) is appropriate for the application, availability of remote electronics, and specific approvals for certain configurations.
RF Admittance Technology and IntelliPoint RF Series: Focuses on RF Admittance technology and IntelliPoint RF series used in floating roof tanks.
Specifications:
  • Electronics Configuration: Integral and remote setups with various cable lengths and types.
  • Output Options: Two SPDT relays with different contact specifications and an 8-16 mA output option.
  • Power Supply: Universal power supply options ranging from 21-100 VDC and 85-250 VAC, with a two-wire power supply option (13-30 VDC).
  • Measurement Type: Manual calibration options, including high sensitivity settings.
Housing and Approvals:
  • Various housing options with NEMA 4X/IP66 ratings and conduit entries.
  • Approval options include ATEX, FM, and CSA, with configurations for dual seal and Perm-a-Seal sensors.
Safety and Compliance:
  • SIL ratings available, including SIL1 and SIL2.
  • Safety switch configurations specified.
Applications:
  • Designed for use in floating roof tanks, with specific sensing elements and alarm trip points for conductive liquids and metal roofs.
Contact Information: Drexelbrook contact details are provided for further inquiries.
See more

Catalog excerpts

SXRLTX Series, Floating Roof Tanks-1

DATA SHEET ® A Leader In Level Measurement Solutions Floating Roof Tanks Spill Prevention Spill Prevention • No calibration or setpoint adjustments. • No calibration or setpoint adjustments. • Automatically recognizes and ignores coatings to • Automatically recognizes and ignores coatings to prevent false alarms. prevent false alarms. • Continuous Self-Test monitors circuits and • Continuous Self-Test monitors circuits and sensing elements for faults sensing elements for faults • Remote or Integral Electronics • Remote or Integral Electronics Dual Compartment Housing Dual Compartment Housing The dual compartment housing separates the The dual compartment housing separates the customer wiring from the sensing element and customer wiring from the sensing element and operating circuits. The encapsulated power supply/ operating circuits. The encapsulated power supply/ terminal block design eliminates the possibility of terminal block design eliminates the possibility of damage caused by moisture in the conduit. damage caused by moisture in the conduit. Self-Test Feature Self-Test Feature Automatic and Local or Remote Manual test functions Automatic and Local or Remote Manual test functions ensure proper system operation. ensure proper system operation. Auto Verify™ Auto Verify™ Each IntelliPoint™ is supplied with a continuous Each IntelliPoint™ is supplied with a continuous self-test feature that constantly monitors the integrity self-test feature that constantly monitors the integrity of not just the electronics, but the sensing element of not just the electronics, but the sensing element • Field Adjustable lengths from 1' to 18' (0.3 to • Field Adjustable lengths from 1' to 18' (0.3 to and interconnecting cable. If a fault is detected, and interconnecting cable. If a fault is detected, 5.48 m) 12" to 216" (305mm to 5486 mm) 5.48 m) 12" to 216" (305mm to 5486 mm) the IntelliPoint Auto Verify™ feature alerts plant the IntelliPoint Auto Verify™ feature alerts plant • Wetted Parts: 316SS 3/4" NPT Mounting, 3/16" personnel. • Wetted Parts: 316SS 3/4" NPT Mounting, 3/16" personnel. FEP insulated flexible and adjustable cable, FEP insulated flexible and adjustable cable, Non-Sparking Brass Sensor. Non-Sparking Brass Sensor. Manual Certify™ Manual Certify™ The IntelliPoint™ provides a method to manually test Features: The IntelliPoint™ provides a method to manually test Features: • Alarm trip points with any contact of internal or the entire system without removing the sensor from • Alarm trip points with any contact of internal or the entire system without removing the sensor from external roof. external roof. the tank. The Manual Certify Test checks that the the tank. The Manual Certify Test checks that the • Alarm trip points in "Sunken Roof" applications Auto Verify circuits are operating and confirms the • Alarm trip points in "Sunken Roof" applications Auto Verify circuits are operating and confirms the with less than 1" product. with less than 1" product. probe and cables are properly connected. The Manual probe and cables are properly connected. The Manual • One system will fit most floating roof tank • One system will fit most floating roof tank Certify also allows the IntelliPoint™ electronics to Certify also allows the IntelliPoint™ electronics to application needs, reducing field spares. application needs, reducing field spares. sense changes in the probe that simulate contact sense changes in the probe that simulate contact with the media or a floating roof. This provides the with the media or a floating roof. This provides the Intelligent Electronics Intelligent Electronics user with a method to insure working performance • Meets API 2350 regulations. user with a method to insure working performance • Meets API 2350 regulations. without having to climb the tank. At the completion • For use in safety related systems with without having to climb the tank. At the completion • For use in safety related systems with requirements for functional safety for SIL2 (SIL of the Certify test routine, the output is momentarily requirements for functional safety for SIL2 (SIL of the Certify test routine, the output is momentarily 3 with Redundant Switch) In accordance to 3 with Redundant Switch) In accordance to held in the alarm state so personnel can confirm that held in the alarm state so personnel can confirm that IEC61508-2, Sec. 7.4.3.1 1999 (Conforms to IEC61508-2, Sec. 7.4.3.1 1999 (Conforms to the control circuits connected to the Final Control the control circuits connected to the Final Control SIL, FMEDA Requirements - Exida) SIL, FMEDA Requirements - Exida) Element are functioning properly. Element are functioning properly. Specifically designed for Floating Roof Specifically designed for Floating Roof Tanks (Internal and External roofs) with Tanks (Internal and External roofs) with Flexible Sensing Element 700-

 Open the catalog to page 1
SXRLTX Series, Floating Roof Tanks-2

Floating Roof Tanks Specifications Floating Roof Tanks Technology: RF Admittance Specifications Calibration: Technology: RF Admittance None Calibration: Operation: Modes Of None Level Fail Safe High Modes Of Operation: Repeatability: High Level Fail Safe conductive liquids 2 mm (0.08 inch) Repeatability: 2Response Time: mm (0.08 inch) conductive liquids Housing: Dual Compartment, Powder-Coated aluminum with two cable entries Housing: Cable Entry: Dual Compartment,CENELEC M20 x 1.5 Powder-Coated aluminum with two cable entries ¾-inch NPT FM/CSA Cable Entry: M20 x Ingress Protection: 1.5 CENELEC...

 Open the catalog to page 2
SXRLTX Series, Floating Roof Tanks-3

Model Numbering Safety Switch S

 Open the catalog to page 3
SXRLTX Series, Floating Roof Tanks-4

Floating Roof Tanks Z-tron IV™ Z4-Series IntelliPoint RF ™ Series Sensing Element for Floating Roof Tanks 700-0005-594-1216.O BAO Bleed Hole Alarm Trip Points • Tip Sensitive on metal roofs and conductive liquids Phone: +1 215-674-1234 • 19044 U.S.A. 205 Keith Valley Road, Horsham, PA Fax: +1 215-674-2731 Tel: 215-674-1234 Fax: 215 674-2731 E-mail: [email protected] Email: [email protected] Web: www.drexelbrook.com 205 Keith Valley Road | Horsham PA 19044 U.S.A. © AMETEK, Inc. All rights reserved. • Printed in the U.S.A. • SXRLTX-A • EDO# 6-10-110

 Open the catalog to page 4

All AMETEK Drexelbrook catalogs and technical brochures

  1. Model 375

    4  Pages

  2. Model 575P

    4  Pages

  3. Model 675

    5  Pages

  4. Model 575S

    5  Pages

  5. Model SDT

    4  Pages

  6. DR6300 Series

    17  Pages

  7. DR5200 Series

    17  Pages

  8. DR7000 Series

    4  Pages

  9. Z4-Series

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.