video corpo

RF Admittance Level Measurement Universal V Pro/Lite Seriess
10Pages

{{requestButtons}}

Catalog excerpts

RF Admittance Level Measurement Universal V Pro/Lite Seriess - 1

DREXELBROOK® AMETEK* RF Admittance/Capacitance Continuous Level Measurement The Universal V™ Series is the fifth generation RF continuous system built on Drexelbrook’s 50 years of experience in level measurement. The product is backward compatible with the industry standard Universal III™, Universal Lite™, Universal II™, RCT™ Series and Universal IV. It is the ideal solution for a wide array of applications. A few enhancements to the Universal V Series include FM/FMc, ATEX amd IECEx hazardous location approval, standard display/keypad, autoranging capabilities and state of the art stable and accurate measurement. Pro Model The Universal V™ Pro model integrates the RF Admittance technology pioneered by Drexelbrook with the versatility of Cote-Shield™ technology that ignores coatings on the probe and measurement span of 1" to 800'. The Pro is compatible with a vast array of applications: conductive, insulating, and heavy or light coating. Lite Model The Universal V™ Lite model is the entry level RF Capacitance measurement system without Cote-Shield™ capabilities. Lite models can be used in non-coating conductive liquids and insulated coating applications where Cote-Shield™ is not required. In addition, the Lite model offers a measurement range up to 20' typically. System Features and Benefits: • Proven Drexelbrook level solution for the most common to the most challenging applications • The most versatile level technology for liquids, slurries, interface and granules measurement • Over 125 probe types for a wide array of applications, flex, rigid, wetted materials and process connections • 2-wire, 4-20mA loop transmitter with the widely accepted digital HART protocol • Process temperature from cryogenic to 1000°F (537°C) • Process pressure from vacuum to 10,000 PSI (690 BAR) • Measurement span as short as 1” (25mm) to 800 ft (244m), no dead zone or blocked measurement areas • Proven Cote-Shield™ technology that ignores coating build-up on the probe • Immune to vapor, dust and foam interference • Immune to tank obstructions such as nozzles, ladders, pipes and agitators • Low cost of ownership, no maintenance, and no moving parts to wear out • Stable, repeatable, and accurate measurement within 0.25% of range • Built-in isolation and surge protection for increased reliability • Easy one-time calibration, configure it once and go • Free PC-based HRTWIN™ configuration software for initial setup from anywhere on the loop or a handheld HART®communicator can be used • Standard user friendly push-button LCD display for configuration and monitoring • Integral and remote installation. The transmitter can be integrated with the probe, or for harsh environmental conditions it can be installed remotely away from the probe/vessel • Hazardous area approvals: FM, FMc, ATEX, IECEx • Hazardous location approvals, Intrinsic Safety (IS) and Explosion Proof for Class I, Div I installations • Fully backward compatible with Drexelbrook's leading products such as Universal III, Universal Lite, RCT and Universal IV series • 50+ years of Drexelbrook applications knowledge that ensures the right solution for your application DREXELBROOK® AMETEK*

Open the catalog to page 1
RF Admittance Level Measurement Universal V Pro/Lite Seriess - 2

Universal V™ Series Pro and Lite Models Integral Configuration One of the Drexelbrook’s key advantages is applications expertise. Drexelbrook offers more than products, we offer solutions that work. Our team of applications engineers will assist you with the ideal solution that solves your problem. The Universal V can be successfully applied across various industries including: oil & gas, chemical, petrochemical, water & wastewater, power, food & beverage, pharmaceutical, pulp & paper, mining & aggregates, feed & grain and much more. Below are some typical applications examples. Integrated...

Open the catalog to page 2
RF Admittance Level Measurement Universal V Pro/Lite Seriess - 3

Applications Examples (Continued) Water and Wastewater Digesters Digesters are commonly used in sewage treatment plants to limit access to oxygen and encourage the generation of methane and carbon dioxide by microbes in the waste. Aerobic and anaerobic digestion is used to decompose organic matter to reduce volume. In some instances the Digester may be a floating roof tank. As the digestion process takes place and the bio-gas is generated, a floating roof tank may be utilized that will allow the user to contain and monitor the amount of bio-gas that is created above the sludge level. The...

Open the catalog to page 3
RF Admittance Level Measurement Universal V Pro/Lite Seriess - 4

V™ Series Universal IV™ Series Pro and Lite Models Universal IV™ Series Pro and Lite Models Probe Selection Probe Selection Series has one of the richest and most versatile probe selections in the industry. Over 125 The Universal IV™ Series has one of the richest and most V™ The Universalbe selectedhas one of the richest and mostUniversalprobe selections in the industry. special probes can standard option in the versatile V probes can IV™ Series as a standard option in the Universal IV model number and many Over 125 probes can be selected as aupon request. Drexelbrook’s bonded probe...

Open the catalog to page 4
RF Admittance Level Measurement Universal V Pro/Lite Seriess - 5

Universal V™ Series Universal IV™ Series Pro and Lite Models Pro and Lite Models Universal IV™ Series Pro and Lite Models Probe selection (Continued) Probe selection (Continued) Probe selection (Continued) Probe Model Typical Applications Construction / Wetted Material Electrostatic desalters, High temp, remote only Flex cable for coating liquids, slurries, granulars and interface. Agitated service when anchored 5/16” PVDF insulated flexible cable Heavy duty for coal, ores and other abrasive material Urethane insulated flexible cable with special impregnation Coating applications, thin...

Open the catalog to page 5
RF Admittance Level Measurement Universal V Pro/Lite Seriess - 6

Universal V™ Series Pro and Lite Models Integral Mounting / Dimensions - inches (mm) SENSING ELEMENT DEPENDENT Remote Mounting / Dimensions - inches (mm) SENSING ELEMENT DEPENDENT

Open the catalog to page 6

All AMETEK Drexelbrook catalogs and technical brochures

  1. Model 375

    4 Pages

  2. Model 575P

    4 Pages

  3. Model 675

    5 Pages

  4. Model 575S

    5 Pages

  5. Model SDT

    4 Pages

  6. DR6300 Series

    17 Pages

  7. DR5200 Series

    17 Pages

  8. Z4-Series

    6 Pages

  9. Model DDMC

    8 Pages

  10. Point Level

    5 Pages

Archived catalogs

  1. Model SDT

    4 Pages

  2. DR7000

    4 Pages