Product catalog summary
Overview: The Drexelbrook IntelliPoint RF Series is a point level switch designed for versatile applications in level measurement. It features intelligent electronics that eliminate the need for calibration or setpoint adjustments, enhancing user-friendliness and efficiency.
Key Features:
  • No calibration or setpoint adjustments required.
  • Automatically adjusts to changes in dielectric or conductivity and recognizes coatings to prevent false alarms.
  • Continuous self-test for monitoring circuits and sensing elements for faults.
  • Universal power supply with automatic input power source detection.
Applications: Suitable for detecting the presence or absence of liquids, slurries, interfaces, and granular materials.
Output: Includes two SPDT relays, with relay #2 configurable as an alarm or fault.
Design: Dual compartment housing isolates the power supply from the intrinsically-safe sensing element and circuit board. Electronics can be remotely mounted for convenience and safety.
Specifications:
  • Housing: Dual Compartment, Powder-Coated aluminum with IP66 NEMA 4X ingress protection.
  • Approvals: Certified for hazardous locations with ATEX and FM/CSA certifications.
  • Technology: RF Admittance with no calibration required.
  • Operating Modes: High and Low Level with 2 mm repeatability for conductive liquids.
  • Response Time: Less than one second.
  • Temperature Range: Ambient electronic temperature from -40 to 70°C, storage temperature from -40 to 85°C.
  • Indicators: LEDs for power and relay status.
  • Power Supply: 85-250 Vac or 21-100 Vdc, auto-detecting without jumpers.
  • Relay Contacts: Two SPDT with a maximum contact load of 5A/250 Vac.
Sensing Elements: Available in various configurations for different applications, including general purpose, high temperature and pressure, corrosive materials, and sanitary applications. Materials include 316SS, PEEK, TFE, and Hastelloy C.
Mounting Options: Includes NPT threads, sanitary TriClamps, ANSI flanges, and DIN flanges, with specific options for different sensing elements and applications.
Conduit Entries and Approvals: Various configurations of conduit entries are outlined, categorized by size and type, such as ¾” NPT and M20 X 1.5, with different approval statuses including FM, CSA, and ATEX. Features like Dual Seal and sensor types (Perm-a-Seal or Non Perm-a-Seal) are specified.
Output and Technology: The IntelliPoint RF Series features an 8-16mA output and utilizes RF Admittance technology, operating with a two-wire power supply ranging from 13-30 VDC.
SIL and Safety Features: Available in SIL1 and SIL2 safety integrity levels, ensuring compliance with safety standards. Includes a safety switch for enhanced operational security.
Electronics and Measurement: The electronics are integral to the system, with a 'No Calibration' measurement type and a 2 pF fixed preload.
Model Numbering: A detailed model numbering system is provided, indicating various configurations and options available for customization.
See more

Catalog excerpts

RF Admittance Level Measurement RXL Series, IntelliPoint-1

A Leader In Level Measurement Solutions IntelliPoint RF Series Point Level Switch One of the Drexelbrook RF Point Level Switches You Won't Have to Calibrate Simply install the IntelliPoint RF Series into the tank and apply power…that's it! Unlike other RF or capacitance systems that require calibration via setpoint potentiometers, jumpers, magnets, or pushbuttons, the IntelliPoint RF Series reliably detects the absence or presence of material without any adjustments. The IntelliPoint RF Series software continuously monitors the application for changes in composition, dielectric or conductivity, and maintains a repeatable trip point on the probe. Other RF and capacitance systems require calibration adjustments when the process material is changed. Since the the IntelliPoint RF Series recognizes changes in material, it is ideal for non-dedicated tanks that are used for a wide variety of products. Universal Power Supply Intelligent Electronics • No calibration or setpoint adjustments. • Ignores changes in dielectric or conductivity. • Automatically recognizes and ignores coatings to prevent false alarms. • Continuous self-test monitors circuits and sensing elements for faults. • Universal power supply automatically detects input power source. Diverse Applications • Detects the absence or presence of liquids, slurries, interfaces and granulars. • (2) SPDT relays; relay#2 can be configured as an alarm or fault. Dual Compartment Housing • Power Supply is isolated from intrinsically-safe sensing element and circuit board. Remote or Integral Electronics • Unlike many technologies, electronics can be remote mounted to a convenient or safe location The IntelliPoint electronics use a universal power supply module that can be powered from a 85 to 250 Vac or 21 to 100 Vdc supply without moving jumpers. Self-Test Feature Automatic and manual test functions ensure proper system operation. An AutoVerify™ selfcheck circuit continuously monitors that the complete system is functioning properly. The Manual Certify not only checks the function of the system, but also checks the AutoVerify self-test circuits to make sure that they are also working properly. Dual Compartment Housing New dual compartment housing separates the customer wiring and power supply from the sensing element and operating circuits. The encapsulated power supply/terminal block design eliminates the possibility of damage caused by moisture in the conduit.

 Open the catalog to page 1
RF Admittance Level Measurement RXL Series, IntelliPoint-2

IntelliPoint RF Series Specifications Technology: RF Admittance. Calibration: None. Modes Of Operation: High and Low Level. Repeatability: 2 mm (0.08 inch) conductive liquids. Response Time: less than one second. Ambient Electronic Temperature: -30 to 70°C (-28 to 158°F) KEMA. -40 to 70°C (-40 to 158°F) FM / CSA. Storage Temperature: -40 to 85°C (-40 to 185°F). Indicators: LEDs: Green Power, Red Relay 1, Red Relay 2. Self-Check: AutoVerify automatically and continuously checks electronics and sensing element for faults. Manual Certify checks that the AutoVerify circuits are functioning. Time...

 Open the catalog to page 2
RF Admittance Level Measurement RXL Series, IntelliPoint-3

RNL IntelliPoint RF Series Model Numbering (continued on next page) IntelliPoint RF TM Technology R RF Admittance Measurement Type L No Calib., 2 pF Fixed Preload P No Calib., 0.5 pF Fixed Preload (High Sensitivity) Manual Calibration Manual Calibration (High Sensitivity) No Calib., 10 pF Fixed Preload No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries ATEX Approved, NEMA 4X/IP66, M20 X 1.5 conduit entries FM Approved, NEMA 4X/IP66, ¾” NPT conduit entries CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries No Approvals, NEMA 4X/IP66, M20 X...

 Open the catalog to page 3
RF Admittance Level Measurement RXL Series, IntelliPoint-4

waterlike viscosity (4) Interface Measurement 69 bar @ 38°C (1000 PSI @ 100°F) 34.5 bar @ 149°C (500 PSI @ 300°F) 20 Miniature Pilot 700-0209-002 remote 6.9 bar @ 121°C (100 PSI @ 250°F) Plant Sensor (1)(7) 0 bar @ 232°C (0 PSI @ 450°F) Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element Pressure/Temperature 31 No hopper Installation 700-0029-001 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 32 Hopper Installation 700-0029-002 remote 0.1 bar @ 260°C (2 PSI @ 500°F) up to 200mm (8 inches) 33 Hopper Installation 700-0029-003 remote 0.1 bar @ 260°C (2 PSI @ 500°F) up to...

 Open the catalog to page 4

All AMETEK Drexelbrook catalogs and technical brochures

  1. Model 375

    4  Pages

  2. Model 575P

    4  Pages

  3. Model 675

    5  Pages

  4. Model 575S

    5  Pages

  5. Model SDT

    4  Pages

  6. DR6300 Series

    17  Pages

  7. DR5200 Series

    17  Pages

  8. DR7000 Series

    4  Pages

  9. Z4-Series

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.