PNL Series, ThePoint, Loop Powered - 1

DATA SHEET Intelligent Electronics Save Time and Money • UNIQUE! - NO calibration or setpoint adjustments. • UNIQUE! - Ignores changes in dielectric or conductivity. • Automatically recognizes and ignores coatings to prevent false alarms. Diverse Applications • Detects the absence or presence of liquids, slurries, and granulars. • Capable of high pressures and temperatures. Economical Without Sacrifice • Retains superior performance. • Less maintenance than other technologies; no moving parts to hang up or wear out. Output • 8mA (Alarm), 16mA (Normal) or • 8mA (Normal), 16mA (Alarm) One of the Drexelbrook RF Point Level Switches You Won't Have to Calibrate Simply install ThePoint Series into the tank and apply power...that's it! Unlike other RF or capacitance systems that require calibration via setpoint potentiometers, jumpers, magnets, or pushbuttons, ThePoint Series reliably detects the absence or presence of material without any adjustments. ThePoint Series software continuously monitors the application for changes in composition, dielectric or conductivity, and maintains a repeatable trip point on the probe. Other RF and capacitance systems require calibration adjustments when the process material is changed. Since ThePoint Series recognizes changes in material, it is ideal for non-dedicated tanks that are used for a wide variety of products. Lower Cost of Ownership In addition to lower initial investment, ThePoint continues to save with little or no maintenance compared with other technologies. Further, the sensor can be lengthened or shortened in the field, saving need for additional purchases. Remote or Integral Electronics Unlike many technologies, electronics can be remote mounted to a convenient or safe location.

Open the catalog to page 1
PNL Series, ThePoint, Loop Powered - 2

Specifications Technology: RF Admittance Calibration: None Modes Of Operation: High and Low Level Repeatability: 2 mm (0.08 inch) conductive liquids Response Time: Less than one second Ambient Electronic Temperature: -40 to 70°C (-40 to 158°f) Storage Temperature: -40 to 85°C (-40 to 185°F) Indicators: LEDs: Green Power, Red Alarm Time Delay: 0-60 seconds, forward or reverse-acting Supply Voltage: 13-30 VDC Power Consumption: 2 watts maximum Output: 8mA (Alarm), 16mA (Normal) or 8mA (Normal), 16mA (Alarm) Housing: Powder-Coated aluminum with two cable entries. Cable Entry: M20 x 1.5 or...

Open the catalog to page 2
PNL Series, ThePoint, Loop Powered - 3

Model Numbering (continued on next page) Technology P RF Admittance Measurement Type N Std Auto Cal H Hi Sense .5 pF Auto Cal Hi Sense .5 pF Fixed Hi Sense Manual Std Sense Manual NOTE: All Calibration modes are built into the standard unit. Modes can be changed in the field as required. (See Instruction Manual) T Two Wire Power Supply 13 to 30 Vdc Output 0 8-16 mA Housing 0 No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries 1 No Approvals, NEMA 4X/IP66, %” NPT conduit entries 2 ATEX / Testsafe Approved, NEMA 4X/IP66, M20 X 1.5 conduit entries 3 FM / FMc / Testsafe approved,...

Open the catalog to page 3
PNL Series, ThePoint, Loop Powered - 4

Model Numbering (cor)tinuedfrom previous page) 19 Interface Measurement 700-0002-023 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element Pressure/Temperature up to 635mm (25 inches) Plugged Chute Detection (1) (5) Application Sensing Element 50 Flush Mount Sensor 700-0207-001 remote 53 Flush Mount Sensor 305mm2 (12 inches2) extra heavy duty 55 Flush Mount Sensor 203mm2 (8 inches2) heavy duty High Pressure / High Temperature 60 High Pressure & Temp. 700-020)-038 remote 62 High Pressure...

Open the catalog to page 4

All AMETEK Drexelbrook catalogs and technical brochures

  1. Model 375

    4 Pages

  2. Model 575P

    4 Pages

  3. Model 675

    5 Pages

  4. Model 575S

    5 Pages

  5. Model SDT

    4 Pages

  6. DR6300 Series

    17 Pages

  7. DR5200 Series

    17 Pages

  8. Z4-Series

    6 Pages

  9. Model DDMC

    8 Pages

  10. Point Level

    5 Pages

Archived catalogs

  1. Model SDT

    4 Pages

  2. DR7000

    4 Pages