1. Catalogs
  2. AMETEK Drexelbrook
  3. IntelliPoint RF™ Series

IntelliPoint RF™ Series
1 /4Pages

IntelliPoint RF™ Series

IntelliPoint RF™ Series
1 /4Pages

Catalog excerpts

IntelliPoint RF™ Series-1

DATA SHEET DREXELBROOKIntelliPoint RF™ Series Two-Wire Point Level Switch • No calibration or setpoint adjustments. • Ignores changes in dielectric or conductivity. • Automatically recognizes and ignores coatings to prevent false alarms. • Continuous self-test monitors circuits and sensing elements for faults. • Detects the absence or presence of liquids, slurries, interfaces and granulars. • 8mA (Alarm) 16mA (Normal) or 8mA (Normal) and 16 mA (Alarm) • Unlike many technologies, electronics can be remote mounted to a convenient or safe location The only RF switch you won't calibrate. Simply install the IntelliPoint RF Series into the tank and apply power...that's it! Unlike other RF or capacitance systems that require calibration via setpoint potentiometers, jumpers, magnets, or pushbuttons, the IntelliPoint RF Series reliably detects the absence or presence of material without any adjustments. The IntelliPoint RF Series software continuously monitors the application for changes in composition, dielectric or conductivity, and maintains a repeatable trip point on the probe. Other RF and capacitance systems require calibration adjustments when the process material is changed. Since the IntelliPoint RF Series recognizes changes in material, it is ideal for non-dedicated tanks that are used for a wide variety of products. Automatic and manual test functions ensure proper system operation. An AutoVerify™ self-check circuit continuously monitors that the complete system is functioning properly. The Manual Certify not only checks the function of the system, but also checks the AutoVerify self-test circuits to make sure that they are also working properly. New dual compartment housing separates the customer wiring from the sensing element and operating circuits. The encapsulated power supply/ terminal block design eliminates the possibility of damage caused by moisture in the conduit.

 Open the catalog to page 1
IntelliPoint RF™ Series-2

Specifications Technology: RF Admittance Calibration: None Modes Of Operation: High and Low Level Repeatability: 2 mm (0.08 inch) conductive liquids Response Time: Less than one second Ambient Electronic Temperature: Storage Temperature: LEDs: Green Power, Red Alarm AutoVerify automatically and continuously checks electronics and sensing element for faults. Manual Certify checks that the AutoVerify circuits are functioning. Cable Entry: M20 x 1.5 ATEX / lECEx %-inch NPT FM / FMc Ingress Protection: IP66 NEMA 4X FM approved. Explosion-proof for use in Class I, Division 1, Groups A, B, C, & D;...

 Open the catalog to page 2
IntelliPoint RF™ Series-3

Model Numbering (continued on next page) IntelliPoint RF TM Measurement Type N No Calibration (Standard) M Manual Setpoint Adjustment H High Sensitivity G High Sensitivity Manual Setpoint Adjustment L Standard Auto Calibration 10pf Auto Calibration 10pf Fixed High Sensitivity .5 pf Fixed High Sensitivity Input T Two wire Power Supply, 13-30 Vdc Housing 0 1 2 3 5 6 7 9 A B No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries ATEX / IECEx Approved, NEMA 4X/IP66, M20 X 1.5 conduit entries FM / FMc Approved, NEMA 4X/IP66, ¾” NPT conduit entries...

 Open the catalog to page 3
IntelliPoint RF™ Series-4

Model Numbering (continued from previous pisage^) Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element 31 No hopper Installation 7\\-\\29-\\1 regot) 32 Hopper Installation 7\\-\\29-\\2 regot) 33 Hopper Installation up to 4\6gg (16 inches) 34 Hopper Instalation up to 521gg (2\.5 inches) 35 Hopper Installation 7\\-\\29-\\5 regote Plugged Chute Detection (1) (5) Application Sensing Element 50 Flush Mount Sensor 7\\-\2\7-\\1 regote 51 Flush Mount Sensor 3\5gg2 (12 inches2) higher tegperature Wetted Parts Wetted Parts 53 Flush Mount Sensor 3\5gg2 (12 inches2) extra...

 Open the catalog to page 4

All AMETEK Drexelbrook catalogs and technical brochures

  1. Model 375

    4  Pages

  2. Model 575P

    4  Pages

  3. Model 675

    5  Pages

  4. Model 575S

    5  Pages

  5. Model SDT

    4  Pages

  6. DR6300 Series

    17  Pages

  7. Z4-Series

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.