1. Catalogs
  2. AMETEK Drexelbrook
  3. Desalter Interface Measurement

Desalter Interface Measurement

Desalter Interface Measurement

Desalter Interface Measurement

Product catalog summary
Overview: The document discusses Drexelbrook's solutions for desalter interface measurement, focusing on maximizing throughput and reducing maintenance costs in oil/water separators. The technology is designed to operate independently of density, temperature, and pressure changes, making it suitable for all electrostatic separators.
Key Features:
  • Maximizes throughput by reducing water content in crude oil.
  • Reduces maintenance costs due to the absence of moving parts.
  • Measures close to the grids for optimal efficiency.
  • Worldwide approvals for use in various conditions.
Technical Specifications:
  • Span: Minimum 6 inches (152 mm) to full active section.
  • Supply Voltage: 24 Vdc nominal, operational range 11.5 to 50 Vdc.
  • Load Resistance: 625 ohm at 24 Vdc.
  • Output: 4-20 mA, current limit to 28 mA.
  • Ambient Temperature Limits: -40 to +170°F (-40 to +75°C).
  • Approvals: FM/ATEX/IECEX Class I, Div I.
  • DC Voltage Isolation: 3500 VDc to ground.
  • Sensor Maximum Temperature and Pressure: 450°F at 500 PSI (232°C at 35 BAR).
  • Sensor Mounting: 1-inch NPT or Flange as specified.
  • Sensor Wetted Parts: 316 SS and TFE.
Applications: The RF Interface Transmitters are applicable for thermoelectric treaters and other electrostatic coalescers. They accurately measure the electrical interface in emulsions, even in upset conditions, and are unaffected by density changes.
System Components:
  • Electronic Unit: Mounted remotely from the sensing element.
  • Cable: Standard length of 25' (8m), with options up to 100' (30m).
  • Sensing Element: Includes cooling extension and all metal wetted parts in 316 SS standard.
  • Protection: Surge/transient/lightning and electrostatic grid protection.
Additional Instruments:
  • Water Guard: Provides an alarm if oil levels get too low in the separator.
  • Cut Monitor: Measures the percentage of water in product oil.
  • Interface Point Level Measurement: For continuous interface measurement in other separation vessels.
Contact Information: Drexelbrook, 205 Keith Valley Road, Horsham, PA 19044, U.S.A. Tel: 215-674-1234, Fax: 215-674-2731, Email: [email protected], Web: www.drexelbrook.com
See more

Catalog excerpts

Desalter Interface Measurement-1

A Leader In Level Measurement Solutions Desalter Interface Measurement For all Electrostatic Separators Maximize throughput of oil/water separators with reliable, no maintenance, level transmitters. A typical separator contains four phases: Oil on the top (electrically insulating), water and sediment at the bottom (electrically conductive), and a two-part emulsion phase in-between. The upper part of the emulsion phase consists of wet oil (water particles surrounded by oil which is electrically insulating). The lower part is oily water (oil particles surrounded by water which is electrically conducting.) There is an electrical interface in the emulsion where the wet oil meets the oily water. Maximize Throughput • Reduces water content in crude oil Reduces Maintenance Costs • No moving parts. Measures close to the grids Worldwide Approvals Measurement Independent of density, temperature, and pressure changes The electrostatic field operates at maximum efficiency when this electrical interface is close to the electrostatic grid. If this electrical interface is too far away from the grids, coalescing efficiency is significantly reduced. If it touches the grid, it draws huge currents. AMETEK Drexelbrook’s RF Interface Transmitters accurately measure the electrical interface in the emulsion even in upset conditions. The transmitter allows operators to keep this electrical interface close (but not too close) to the grids, to maximize throughput. The AMETEK Drexelbrook instrument also ignores build-up on the sensing element, and is unaffected by density changes It is also applicable for thermoelectric treaters and other electrostatic coalescers.

 Open the catalog to page 1
Desalter Interface Measurement-2

Desalter Interface Measurement Specifications Span (min/max) 6 inches (152 mm) to full active section Supply Voltage 24 Vdc nominal (works with 11.5 to 50 Vdc) Load Resistance Ambient Temp Limits Sensor Maximum Temperature and Pressure Sensor Mounting Sensor Wetted Parts All systems include: 1. Electronic Unit for mounting remotely from sensing element. 2. Cable between electronic unit and sensing element. Std. length is 25' (8m); options up to 100' (30m). 3. Sensing Element with cooling extension, inactive, all metal wetted parts 316 SS standard. Note: Specify inactive length to extend from...

 Open the catalog to page 2

All AMETEK Drexelbrook catalogs and technical brochures

  1. Model 375

    4  Pages

  2. Model 575P

    4  Pages

  3. Model 675

    5  Pages

  4. Model 575S

    5  Pages

  5. Model SDT

    4  Pages

  6. DR6300 Series

    17  Pages

  7. DR5200 Series

    17  Pages

  8. DR7000 Series

    4  Pages

  9. Z4-Series

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.