XP2i Data Recorder
6Pages

{{requestButtons}}

Catalog excerpts

XP2i Data Recorder - 1

Advanced Pressure Module

Open the catalog to page 1
XP2i Data Recorder - 2

Expand Your Multi-Purpose Signal Calibrator Now Measure Pressure! Crystal APM offers seamless integration with JOFRA calibrators like the ASC Series. HE CRYSTAL APM CPF SERIES pressure module, with integrated CPF  female connection, offers the functionality and flexibility to perform pressure calibrations with a multifunction signal calibrator. In addition, when connected to a hand-held pressure calibrator, the APM can expand its pressure range. The APM is engineered to deliver the same high level of accuracy whether in the lab or in the field. Combined with calibrators and pump systems,...

Open the catalog to page 2
XP2i Data Recorder - 3

Lab Accuracy in the Field Active Temperature Compensation Count on the same accuracy at any temperature, between -20 and 50° C. Crystal Pressure Fittings are machined in high-strength 316 Stainless Steel to operate to 10 000 psi /700 bar.  Purpose designed for testing. Calibrate with Confidence Anywhere Take measurements with up to 0.025% of reading accuracy. Crystal Engineering calibration facilities are A2LA accredited, (# 2601.01) which is internationally recognized by ILAC.  Self-venting weep hole alerts you before you disconnect from a pressurized system.  Seamless connection to...

Open the catalog to page 3
XP2i Data Recorder - 4

Specifications Accuracy Operating Temperature Wetted Materials. . . . . . . . (wrench tight) 316 stainless steel (finger tight) 316 stainless steel and Viton® (internal o-ring) 3, 10 and 30 bar 300 kPa, 1 and 3 MPa 0 to 30% of Range . . . . . . ±(0.0075% of Full Scale) 30 to 110% of Range. . . . ±(0.025% of Reading) Vacuum. . . . . . . . . . . . . . . . . For 100 psi / 10 bar / 1 MPa and lower: ±(0.06% of Full Scale*) For 300 psi / 30 bar / 3 MPa: ±(0.06% of Full Scale*) ±1 LSD Diaphragm Seal Fluid. . . Silicone Oil Connection. . . . . . . . . . . . . Crystal CPF Female All welded, with a...

Open the catalog to page 4
XP2i Data Recorder - 5

Accuracies, Ranges, and Resolutions psi 0.025% of Reading modules Resolutions shown are the maximum resolutions available. The resolution of your JOFRA device may be different. * CPF adaptor fitting is not included. 1/4" medium pressure tube system is compatible with HIP LM4 and LF4 Series, Autoclave Engr SF250CX Male and Female Series. See our CPF data sheet for additional adapter fittings. Ordering Information Model Fitting      SAMPLE PART NUMBERS APM30PSI . . . . . . . . . . . . . . . 30 psi APM with a 1/4" NPT pressure fitting

Open the catalog to page 5
XP2i Data Recorder - 6

Singapore Tel +65 6484 2388 jofra@ametek.com USA, Florida Tel +1 (800) 527 9999 cal.info@ametek.com China, Shanghai Tel +86 21 5868 5111 jofra.sales@ametek.com.cn China, Beijing Tel +86 10 8526 2111 jofra.sales@ametek.com.cn China, Guangzhou Tel +86 20 8363 4768 jofra.sales@ametek.com.cn ametekcalibration.com No part of this document may be reproduced or modified in any form or by any means, electronic or mechanical, without express written permission from Crystal Engineering Corporation.