Group: Ametek
Catalog excerpts
Reference Recorder TEST & CALIBRATION INSTRUME
Open the catalog to page 1Your Multi-Purpose Recorder Key Features Quick-change module bays. Switch modules anywhere. Records 1 Million Data Points Simple to Use Intuitive keypad takes seconds to learn. Live Data Graphing Robust Drop tested from 5 feet. Easily accessed mini-USB port. Large, backlit display. LED icons indicate recording BARO Option–Switch between absolute and gauge pressure. Ultra-Low Power Mode: 60 days of operation on 4 AA batteries.
Open the catalog to page 2Temperature & Current Measure, calibrate, and record up to 15 000 psi with up to 0.025% of reading accuracy, in the field. Works with 2-, 3-, and 4-wire PtIOO RTDs. Includes an IP67 rated, M8 connector terminal block. Switch Test Module (MA20) Measures 4-20 mA and 10-50 mA loops, DC voltage, and switch state. Each MA20 module comes with a super flexible, silicone 2mm test lead kit. TEST & CALIBRATION INSTRUMENTS
Open the catalog to page 3Modular Configuration nVision modules put a complete test and calibration system in your toolbox. Pressure+Pressure Record two pressure inputs for up to 8 weeks, and low wet-wet differentials at up to 15 000 PSI static pressure. Well Optimization // Hydraulic Fracturing // Artificial Lift // Christmas Tree // Pump Testing Pressure+Temperature Monitor and record pressure & temperature over the course of a test. Always Seals, Always Safe Hydrostatic // Pressure Vessel Testing Patent Pending Purpose-designed for testing & calibration Pressure+Current Show current and pressure on the same...
Open the catalog to page 4Lab Accuracy in the Field Active Temperature Compensation Count on the same accuracy at any temperature, between -20 and 50° C. & High Accuracy $250,000 Saved in 6 Months Before nVision, I had no way of testing my lters. I was replacing them every few months without knowing if I needed to. Calibrate with Confidence Anywhere Now, I test my lters at full line pressure and replace them only when necessary. Using nVision, we saved $250,000 Take measurements with up to 0.025% of reading accuracy. Certified by our A2LA/ILAC accredited calibration laboratory. We also had documentation to show...
Open the catalog to page 5Multiple Data Views Visualize Your Data View data from each module separately, or combine the data from both modules into one graph. See Changes As You Record Skip the trip back to the lab. Examine your data in the field while you record your test. Zoom and Pan Across Data Take a closer look. Use the arrow keys to inspect the details of your last data run. Original View
Open the catalog to page 6Your Device, Your Way Customize, secure, and configure your nVision with CrystalControl software. Access, view, and export your data with DataViewer. Sort, enable, and assign numbers to screens to match need and define a custom unit ► Safety Start-up Screen Prompt users to acknowledge- a custom safety message with the press of a button, before Firmware Version: Screen Lock Password: | Set Password... Message Store: Logging Interval: loparamond Recoi cling Time: 9.4 how s ► Tamper-Proof Digital Records Securely export your digital- recording directly into an industry- Start nVision...
Open the catalog to page 7Applications Differential Pressure Gauge and Recorder Calibration and Test Tool Chart Recorder Replacement Orifice Plate Custody Transfer Extended Recording Measure and record low differentials at high Field calibrate the high-accuracy equipment nVision replaces chart recorders with static pressure directly across an orifice plate. used in commercial transactions. higher accuracy in a smaller, lighter, more Filter Testing Save money by testing filters for clogs and Capture and record relief valve seat and reseat wear, before replacing them. pressure at 10 readings per second. Differential...
Open the catalog to page 8Crystal Engineering Corporation 708 Fiero Lane, Suite 9, San Luis Obispo, CA 93401, USA Telephone: +1 805.595.5477 | Fax: +1 805.595.5466 Safe & Reliable in Hazardous Environments II 1G Ex ia IIB T4 Ga -or- Ex ia IIB T3 Ga Dear Pressure Gauge User, At Crystal Engineering we believe perfection is possible. We hold in mind our mission to produce the products that make your work easier. nVision started with you—our customers—with your ideas, your phone calls, your requests for features. You told us what you needed. We built what you asked for. The device we designed is task configurable, with...
Open the catalog to page 9All Ametek Calibration catalogs and technical brochures
-
PTC series
14 Pages
-
RTC series
15 Pages
-
Type T Deadweight Tester
8 Pages
-
HL Deadweight Tester
4 Pages
-
HK Deadweight Tester
2 Pages
-
RK Deadweight Tester
3 Pages
-
PK II
3 Pages
-
XP2i Data Recorder
6 Pages
-
ATMi
7 Pages
-
HPC50
6 Pages
-
Temperature Pressure Process
12 Pages
-
AMETEK Calibration Brochure
12 Pages
-
CrystalCalHP
7 Pages
-
Maritime Brochure
8 Pages
-
m1M Manual
4 Pages
-
m1M Data Sheet
4 Pages
-
CPF Brochure (D)
4 Pages
-
APM Advanced Pressure Module
6 Pages
-
HPC40 Series Calibrator
6 Pages
-
Product Overview Brochure
8 Pages
-
GaugeCalHP Manual
20 Pages
-
24 VDC Power Supply Manual
7 Pages
-
24 VDC Power Supply
4 Pages
-
30 Series
4 Pages
-
FastCalXP
9 Pages
-
Lab Reference Recorder
2 Pages