Crystal Wpressure #1% HPC40 Series Calibrator MPa pressure|ACCURACY ^PRESSURE MEASUREMENT MPa (Gauge Pressure)► 18 to 28° C0 to 30% of Range: ±(0.01% of Full Scale) 30 to 110% of Range: ±(0.035% of Reading) Vacuum*: ±(0.05% of Full Scale**)► -20 to 50° C0 to 30% of Range: ±(0.015% of Full Scale) 30 to 110% of Range: ±(0.050% of Reading) Vacuum*: ±(0.05% of Full Scale**) * Applies to 3 MPa and lower ranges only. Vacuum Range = -1 MPa. ** Full Scale is the numerical value of the positive pressure range. MPaA (Absolute Pressure with BARO Option) ► All absolute accuracies are equivalent to the gauge pressure accuracies, except as noted below. 300 kPa Range: Gauge Accuracy +0.03 kPaA 1 MPa Range: Gauge Accuracy+0.00001 MPaA Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. All models indicate vacuum, but vacuum specification applies to 300 kPa, 1 MPa, and 3 MPa models only. Not recommended for continuous use at high vacuum. Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use. The BARO option allows you to toggle between gauge and absolute pressure. [ADVANCED PRESSURE MODULES We offer a range of fully calibrated Advanced Pressure Modules to supplement the HPC40 Series' built-in pressure sensors. Full scale pressure range is from 300 kPa to 100 MPa, with accuracies from ± 0.025 % rdg, and fully temperature compensated from -20 to 50 °C. APM CPF Series Pressure Modules ADDITIONAL SENSOR LENGTH WITH OPTIONAL FITTING ADAPTERS
Open the catalog to page 1HPC40 Series Calibrator MPa| DIFFERENTIAL PRESSURE The Tare function can improve differential pressure measurement uncertainties. Requires the use of an equalizing valve. Full Scale Range of Both Sensors The Greater of (+/-)
Open the catalog to page 2HPC40 Series Calibrator MPa | CURRENT & VOLTAGE MEASUREMENT Connection: 4 mm jacks Maximum Voltage: 45 VDC Current (mA) Input Accuracy: mA Range: Percent Range: Max Allowable Current: Input Resistance: Voltage Burden @ 20mA: Voltage Burden @ 50mA: HART Resistor: 0.001 mA or 0.01% mA and %< 17.2 n< 0.35 V< 0.86 V 250 n Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. Inputs protected by a resettable fuse. mA can be displayed as a percentage, where 0 to 100% corresponds to either 0 to 20,4 to 20, or 10 to 50 mA. Jacks are compatible with safety...
Open the catalog to page 3HPC40 Series Calibrator MPa | TEMPERATURE MEASUREMENT Accuracy: ±(0.015% of rdg) + 0.02 Ohm 0 - 400 Ohms 0.01 on all scales°C, K, °F, R, O0.003850 0/0/°C (IEC 60751) Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. To order a non-calibrated sensor from -45 to 150 °C, order part number 127387. To order a system calibrated sensor, see the Ordering Information table on page 6. 2-, 3-, and 4-wire supportLemo Plug, 1S Series, 304 insert configuration The proper selection of the RTD sensing element is very important as the error associated with...
Open the catalog to page 4HPC40 Series complies with the Electromagnetic Compatibility and the Pressure Equipment Directives. HPC40 Series complies with the Australian Radiocommunications (Electromagnetic Compatibility) Standard 2008. Battery Life: >12 hours non-sourcing >8 hours when sourcing 12 mA Recharge Time: 16 hours* (Using Eneloop 2100 mA * Charging is done through USB , except when supplying loop Uses 4 alkaline AA (LR6) batteries. Housing: Machined Aluminum Keypad and Labels: UV Resistant Silicone Weight is for dual sensor model with protective boot installed. LCD protected from impact damage by 0.5 mm (0.02")...
Open the catalog to page 5Crystal Wpressure #1% HPC40 Series Calibrator MPa | RANGE & RESOLUTION TABLE P/N Display Resolution Range Over-(MPa) pressure ~ The Waterproof Case is an option for Systems A, B, and C only . Single Sensor (10 MPa) HPC40 with a 1/4" NPT pressure fitting. . Dual Sensor (30 MPa/70 MPa) HPC40 with the BARO option, a 1/4" BSP pressure fitting, and STS050 Probe temperature sensor. . Dual Sensor (10 MPa/70 MPa) HPC40 with a 1/4" NPT pressure fitting; a System G pump system; and a waterproof carrying case. ► Ordering a Pump System Only Any pump system, carrying case, and connection fittings for an HPC40...
Open the catalog to page 6Crystal Wpressure #1%| PUMP SYSTEMS OVERVIEW HPC40 Series Calibrator MPa Case Options II Aluminum Waterproof (Pelican Case) © 2021 Crystal Engineering Corporation 708 Fiero Lane, Suite 9, San Luis Obispo, California 93401-8701 Page 7 of 7 sensors, test & calibratioi