Crystal Wpressure #1% HPC40 Series Calibrator bar pressure|ACCURACY ^PRESSURE MEASUREMENT bar (Gauge Pressure)► 18 to 28° C0 to 30% of Range: ±(0.01% of Full Scale) 30 to 110% of Range: ±(0.035% of Reading) Vacuum*: ±(0.05% of Full Scale**)► -20 to 50° C0 to 30% of Range: ±(0.015% of Full Scale) 30 to 110% of Range: ±(0.050% of Reading) Vacuum*: ±(0.05% of Full Scale**) * Applies to 30 bar and lower ranges only. Vacuum Range = -1.0 bar. ** Full Scale is the numerical value of the positive pressure range. barA (Absolute Pressure with BARO Option) ► All absolute accuracies are equivalent to the gauge pressure accuracies, except as noted below. 3 bar Range: Gauge Accuracy +0.0003 barA 10 bar Range: Gauge Accuracy+0.0001 barA Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. All models indicate vacuum, but vacuum specification applies to 3, 10, and 30 bar models only. Not recommended for continuous use at high vacuum. Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use. The BARO option allows you to toggle between gauge and absolute pressure. [ADVANCED PRESSURE MODULES We offer a range of fully calibrated Advanced Pressure Modules to supplement the HPC40 Series' built-in pressure sensors. Full scale pressure range is from 3 to 1000 bar, with accuracies from ± 0.025 % rdg, and fully temperature compensated from -20 to 50 °C. APM CPF Series Pressure Modules ADDITIONAL SENSOR LENGTH WITH OPTIONAL FITTING ADAPTERS
Open the catalog to page 1HPC40 Series Calibrator bar| DIFFERENTIAL PRESSURE The Tare function can improve differential pressure measurement uncertainties. Requires the use of an equalizing valve. Full Scale Range of Both Sensors The Greater of (+/-)
Open the catalog to page 2| CURRENT & VOLTAGE MEASUREMENT Connection: 4 mm jacks Maximum Voltage: 45 VDC Accuracy: mA Range: Percent Range: Max Allowable Current: Input Resistance: Voltage Burden @ 20mA: Voltage Burden @ 50mA: HART Resistor: Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. Inputs protected by a resettable fuse. mA can be displayed as a percentage, where 0 to 100% corresponds to either 0 to 20,4 to 20, or 10 to 50 mA. Jacks are compatible with safety sheathed banana plugs. Current (mA) Output Accuracy: Range: Step Time: Ramp Time: ± (0.015 of rdg +...
Open the catalog to page 3HPC40 Series Calibrator bar Accuracy: | TEMPERATURE MEASUREMENT ±(0.015% of rdg) + 0.02 Ohm 0 - 400 Ohms 0.01 on all scales Lemo Plug, 1S Series, 304 insert configuration The proper selection of the RTD sensing element is very important as the error associated with this device is the majority of the overall system measurement uncertainty. IEC 751 is the standard that defines the temperature versus resistance for 100Q, 0.00385 Q/Q/°C platinum RTDs. IEC 751 defines two classes of RTDs: Class A and B. Class A RTDs operate over the -200 to 630°C range versus -200 to 800°C for the Class B elements....
Open the catalog to page 4HPC40 Series Calibrator bar Type HPC40 Series complies with the Electromagnetic Compatibility and the Pressure Equipment Directives. HPC40 Series complies with the Australian Radiocommunications (Electromagnetic Compatibility) Standard 2008. Battery Life: >12 hours non-sourcing >8 hours when sourcing 12 mA Recharge Time: 16 hours* (Using Eneloop 2100 mA * Charging is done through USB , except when supplying loop Uses 4 alkaline AA (LR6) batteries. Housing: Machined Aluminum Keypad and Labels: UV Resistant Silicone Weight is for dual sensor model with protective boot installed. LCD protected from...
Open the catalog to page 5HPC40 Series Calibrator bar | RANGE & RESOLUTION TABLE Display Resolution ~ The Waterproof Case is an option for Systems A, B, and C only Single Sensor (100 bar) HPC40 with a 1/4" NPT pressure fitting. HPC42-300BAR-700BAR-BAR0-BSP-T3... Dual Sensor (300 bar/700 bar) HPC40 with the BARO option, a 1/4" BSP pressure fitting, and STS050 Probe temperature sensor. pressure fitting; a System G pump system; and a waterproof carrying case. ► Ordering a Pump System Only Any pump system, carrying case, and connection fittings for an HPC40 Series calibrator may be ordered separately from the gauge. Enter...
Open the catalog to page 6| PUMP SYSTEMS OVERVIEW HPC40 Series Calibrator bar Case Options II Aluminum Waterproof (Pelican Case) © 2021 Crystal Engineering Corporation 708 Fiero Lane, Suite 9, San Luis Obispo, California 93401-8701 Page 7 of 7 sensors, test & calibratioi