  3. CrystalControl, nVision Reference Recorder Software Manual

CrystalControl, nVision Reference Recorder Software Manual
1 /25Pages

CrystalControl, nVision Reference Recorder Software Manual

CrystalControl, nVision Reference Recorder Software Manual
1 /25Pages

Catalog excerpts

CrystalControl, nVision Reference Recorder Software Manual-1

for nVision Reference Recorder, HPC50 Series Pressure Calibrator, and HPC40 Series Pressure Calibrator SENSORS, TEST & CALIBRATION

 Open the catalog to page 1
CrystalControl, nVision Reference Recorder Software Manual-2

Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Navigating in CrystalControl . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 2
CrystalControl, nVision Reference Recorder Software Manual-3

Introduction CrystalControl™ is a software program used to customize, update, and calibrate the nVision Reference Recorder and the HPC40 Series Pressure Calibrator. As the features differ depending on the device it is connected to, this manual contains separate sections for each product. To use CrystalControl with an nVision Reference Recorder, refer to the nVision section beginning on page 2. To use CrystalControl with an HPC50 or HPC40 Series Pressure Calibrator, refer to the HPC50 and HPC40 section beginning on page 16. CrystalControl can be used with either the nVision Reference Recorder...

 Open the catalog to page 3
CrystalControl, nVision Reference Recorder Software Manual-4

nVision| OVERVIEW CrystalControl provides an easy way to customize your nVision Reference Recorder while also providing a way to store and archive your recorded data runs. With only a serial cable (P/N: 3951, or equivalent USB A to mini USB B), a computer running Microsoft® Windows®1, and the CrystalControl program you can: • Enable / disable pressure units • Control and configure recordings • Password protect the recorder to prevent unauthorized changes • Identify firmware version • Define a custom message or startup screen • Disable or reorder your display screens • Adjust automatic and backlight...

 Open the catalog to page 4
CrystalControl, nVision Reference Recorder Software Manual-5

  OPERATING INSTRUCTIONS CrystalControl will automatically detect your nVision Reference Recorder when connected. If no nVision is found check cables and verify that the recorder is turned on. Click Find Gauge to reestablish communications. Click Select Gauge.   NAVIGATING IN CRYSTALCONTROL CrystalControl is organized into three major functions: configuration settings (Config), data viewing and archiving (DataViewer), and Tools to set your data storage locations and product update strategies. Config Configure or change settings to the nVision platform, and the Upper, Lower, and BARO modules....

 Open the catalog to page 5
CrystalControl, nVision Reference Recorder Software Manual-6

  CONFIG FUNCTION Configuration settings are arranged in groups such as Platform (nVision) and Modules (Upper, Lower, and BARO). To modify the desired group, simply select the appropriate settings tab on the left. nVision Chassis The only information programmed by the factory is the Model, Serial Number, and Firmware Version; all other information may be modified by CrystalControl. Model: Model of the nVision chassis. Read only. Serial Number: The serial number as reported by the nVision chassis. Read only. Firmware Version: The firmware version and whether updates are available for your nVision...

 Open the catalog to page 6
CrystalControl, nVision Reference Recorder Software Manual-7

Modules: Common to all modules Several of the features are common between all available modules. The only information programmed by the factory is the Model, Serial Number, and Firmware Version; all other information may be modified by CrystalControl. • Model: Model of the nVision module. Read only. • Serial Number: The serial number as reported by the nVision module. Read only. • Firmware Version: The firmware version and whether updates are available for the nVision module.Read only, but may update through Tools. • Calibrated On: Modify the Calibrated On date. Factory set to align with the...

 Open the catalog to page 7
CrystalControl, nVision Reference Recorder Software Manual-8

Modules: Pressure Module The following features are unique to the Pressure Modules (PM): Zero Limit: By default, all pressure modules come pre-programmed with a 20 PSI maximum zero limit. This means that you can apply pressure (up to 20 PSI) to the recorder, press the zero button, and the recorder will read zero. In some situations it may be desirable to increase or decrease the maximum pressure that the recorder could be set to read zero pressure. ! WARNING: This recorder can display zero pressure when connected to a source of pressure! Do not rely on the display indication before disconnecting–...

 Open the catalog to page 8
CrystalControl, nVision Reference Recorder Software Manual-9

Module: BARO The BARO module requires CPLD version 6 or greater to operate properly. If you have CPLD 5 or earlier the nVision must come to the factory for updating. This information may be found on the nVision Config tab. Enable Absolute Mode: You may choose to disable your installed BARO module to save battery power or to prevent the user from accessing the absolute pressure mode. If the User Unit is created using absolute readings, then the BARO must be enabled for the User Unit to be functional. Edit Calibration Data Button: This section includes a Calibration Wizard to help calculate the...

 Open the catalog to page 9
CrystalControl, nVision Reference Recorder Software Manual-10

Modules: Current, Voltage, & Switch Test (MA20) Note: The MA20 module requires CrystalControl 1.2 or greater, and Chassis firmware R080005 or greater to operate properly. The MA20 Module Instructions (P/N 4339) provide further details if required. The following features are unique to the Current, Voltage, & Switch Test Modules (MA20): mA: In addition to the Userspan, this module allows for an offset value to be entered VDC: In addition to the Userspan, this module allows for an offset value to be entered. Changing the Userspan or offset value changes the calibration of the module. Changes in...

 Open the catalog to page 10
CrystalControl, nVision Reference Recorder Software Manual-11

Modules: Temperature Module (RTD100) The following features are unique to the Temperature Modules (RTD100): Temperature Coefficient of Resistance (TCR): Select your appropriate platinum RTD Temperature Coefficient of Resistance (TCR) from the pull down menu. When selected, the pre-populated Callendar-Van Dusen Coefficients will appear. See the nVision Operation Manual for further details on RTDs and the RTD100 module. Base Resistance (Ro): Adjust your RTD resistance at 0°C. Factory default is 100Ω. Lead Type: Adjust your RTD sensor wiring between 2-, 3-, or 4-wire methods. Typical view of RTD100...

 Open the catalog to page 11