Group: Ametek
Catalog excerpts

APMi Series Intrinsically Safe Advanced Pressure Module
Open the catalog to page 1
Expand Your HPC50 Pressure Calibrator Now Measure up to 4 Pressures at Once! Crystal APMi offers seamless integration with the Crystal HPC50 Series. HE CRYSTAL APMi intrinsically safe pressure modules, with integrat- ed CPF female connections offer the functionality and flexibility to read up to 4 pressure inputs with a single HPC50 calibrator. In addition to the two installed modules in the HPC50 Series, two APMi pressure modules can be connected to the device. This provides the flexibility to either expand the range of the HPC50, view all four pressure readings at the same time, or to...
Open the catalog to page 2
Lab Accuracy in the Field Active Temperature Compensation Count on the same accuracy at any temperature, between -20 and 50° C. Crystal Pressure Fittings are machined in high-strength 316 Stainless Steel to operate to 10 000 psi / 700 bar. Purpose designed for testing. Calibrate with Confidence Anywhere Take measurements with up to 0.035% of reading accuracy. Crystal Engineering calibration facilities are A2LA accredited, (# 2601.01) which is internationally recognized by ILAC. Self-venting weep hole alerts you before you disconnect from a pressurized system. Seamless connection to...
Open the catalog to page 3
Specifications Accuracy psi (Gauge Pressure) XX18 to 28° C 0 to 30% of Range: ±(0.01% of Full Scale) Sensor Wetted Materials. . . . . . (wrench tight) 316 stainless steel (finger tight) 316 stainless steel and Viton® (internal o-ring) (15 psi / 1 bar / 100 kPa) 316 stainless steel and Viton 30 to 110% of Range: ±(0.035% of Reading) Vacuum* : ±(0.05% of Full Scale**) XX-20 to 50° C 0 to 30% of Range: ±(0.015% of Full Scale) 30 to 110% of Range: ±(0.050% of Reading) Vacuum* : ±(0.05% of Full Scale**) * Applies to 300 psi / 30 bar / 3 MPa and lower ranges only. Vacuum Range = -14.5 psi / -1.0...
Open the catalog to page 4
Accuracies, Ranges, and Resolutions psi Resolutions shown are the maximum resolutions available. The resolution of your Crystal device may be different. * CPF adaptor fitting is not included. 1/4" medium pressure tube system is compatible with HIP LM4 and LF4 Series, Autoclave Engr SF250CX Male and Female Series. See our CPF data sheet for additional adapter fittings. Ordering Information Model Fitting Interface Cable Length SAMPLE PART NUMBERS APMi30PSI . . . . . . . . . . . . . . . . . 30 psi APMi with a 1/4" NPT male pressure fitting and 1 meter cable. APMi700BAR-BSP-3M . . . 700...
Open the catalog to page 5
Accessories and Replacement Parts MPM-1/4MPT CPF Male to 1/4” Male NPT Fitting Included as standard MPM-1/4BSPM CPF Male to 1/4” Male BSP Fitting Included with -BSP MPM-M20x1.5M CPF Male to M20 Male Adapter China, Shanghai Tel +86 21 5868 5111 jofra.sales@ametek.com.cn China, Beijing Tel +86 10 8526 2111 jofra.sales@ametek.com.cn China, Guangzhou Tel +86 20 8363 4768 jofra.sales@ametek.com.cn ametekcalibration.com No part of this document may be reproduced or modified in any form or by any means, electronic or mechanical, without express written permission from Crystal Engineering...
Open the catalog to page 6All Ametek Calibration catalogs and technical brochures
-
PTC series
14 Pages
-
RTC series
15 Pages
-
Type T Deadweight Tester
8 Pages
-
HL Deadweight Tester
4 Pages
-
HK Deadweight Tester
2 Pages
-
RK Deadweight Tester
3 Pages
-
PK II
3 Pages
-
XP2i Data Recorder
6 Pages
-
ATMi
7 Pages
-
HPC50
6 Pages
-
Temperature Pressure Process
12 Pages
-
AMETEK Calibration Brochure
12 Pages
-
CrystalCalHP
7 Pages
-
Maritime Brochure
8 Pages
-
m1M Manual
4 Pages
-
m1M Data Sheet
4 Pages
-
CPF Brochure (D)
4 Pages
-
APM Advanced Pressure Module
6 Pages
-
HPC40 Series Calibrator
6 Pages
-
Product Overview Brochure
8 Pages
-
GaugeCalHP Manual
20 Pages
-
24 VDC Power Supply Manual
7 Pages
-
24 VDC Power Supply
4 Pages
-
30 Series
4 Pages
-
FastCalXP
9 Pages
-
Lab Reference Recorder
2 Pages