30 Series Calibrator bar ACCURACY–PRESSURE MEASUREMENT 0 to 110% of Range: ±(0.05% of Reading + Floor Term) Floor Term: 0.005% of FS or display resolution, whichever is greater Vacuum: ±(0.25% of Reading + Vacuum Floor Term) Vacuum Floor Term: 0.0003 bar for 1 and 2 bar 0.001 bar for 20 bar ACCURACY– MILLIAMPERES Accuracy: ±(0.025% of Reading + 0.001 mA) Range: 0 to 55 mA Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. All models indicate vacuum, but vacuum specification applies to 1 bar, 2 bar, and 20 bar models only. Not recommended for continuous use below -1 bar. Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use. 2 LINE 8 CHARACTER LCD DISPLAY 0 4mm SHIELDED BANANA JACKS Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. mA can be displayed as a percentage, where 0 to 100% corresponds to either 4 to 20 mA or 10 to 50 mA. Jacks are compatible with safety sheathed banana plugs. OPERATING TEMPERATURE Screen: 2 lines of up to 6 digits, 5 mm (0.2") high Display Rate: 2 readings/second (Adjustable to 1, 3, or 3.7 readings/second) MICRO-USB CONNECTION Pressure Calibrator Resolution: 0.001 mA Connection: 4 mm jacks, 19 mm (0.75") spacing Intrinsically Safe SENSOR DIAPHRAGM LOCATIONS 1/8" FNPT PRESSURE PORTS Non-condensing. No change in accuracy over operating temperature range. Gauge must be zeroed to achieve rated specification. DO NOT EXCEED MAXIMUMS LCD readable in sunlight. Changes to reading rate requires software: ConfigM30 is a free download from crystalengineering.net/downloads/30series. PRESSURE PORT VOLUMETRIC DATA: LP distance to diaphragm ( A to B ): 22.4 (0.88") LP volume: 2 ml (0.13 cubic inches) HP distance to diaphragm ( A to B ): 17.8 (0.70") HP volume: 1 ml (0.06 cubic inches) 4598 . I 30 Series bar Data Sheet Page 1 of 5
Open the catalog to page 130 Series Calibrator bar POWER The 30 Series is Intrinsically Safe only if powered by one of the following battery types. Approved Battery Type Duracell Alkaline 9V, MN 1604 Energizer Alkaline 9V, 522 Energizer Lithium 9V, L522 Varta High Energy Alkaline 9V, 4922 Approved Battery Type This product conforms to: EN 60079-0: 2006 | EN 60079-11: 2007 II 2G Ex ia IIC T4 Gb IECEx FTZU 10.0018X Duracell Alkaline 9V, MN 1604 Energizer Alkaline 9V, 522 This product conforms to: IEC 60079-0: 2007 | IEC 60079-11: 2006 Exia Intrinsically Safe and Non-incendive for Hazardous Locations: Class I,...
Open the catalog to page 230 Series Calibrator bar SENSOR ≥ 100 bar Wetted Materials: 316 stainless steel All welded with a permanently filled diaphragm seal. Diaphragm Seal Fluid: Silicone Oil Connection: Bottom, 1⁄8 " female NPT Wetted Materials: 316 stainless steel, Viton® (o-ring) Viton o-ring is internal. All welded with a permanently filled diaphragm seal. Anodized aluminum penetrated with PTFE (polytetrafluoroethylene) Diaphragm Seal Fluid: Silicone Oil Connection: Bottom, 1⁄8 " female NPT STORAGE TEMPERATURE SPECIAL FEATURES he following requires the use of ConfigM30 software T Batteries should be removed...
Open the catalog to page 330 Series Calibrator bar RANGE & RESOLUTION TABLES DUAL PRESSURE SENSORS Model 33 callibrators have dual pressure sensors. This chart shows all of the available sensor combinations. Second Pressure Ranges 20 bar 100 bar 200 bar First Pressure Ranges Model 31 calibrators are not available in this range. ORDERING INFORMATION * Intrinsic Safety Pressure Manifold Standard. . . . . . . . (omit) Stainless Steel. . . -SPSS Pressure Unit Pump System** Carrying Case~ Full . . . . . . . (omit) Aluminum . . . . (omit) SAMPLE PART NUMBERS IS31-2BAR. . . . . . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 430 Series Calibrator bar PUMP SYSTEMS All pump systems for the 30 Series include 1/4 NPT and BSP female fittings, (2) MPF-1/8MPT fittings, and a carrying case with custom insert. Additional fittings and accessories included with individual systems are listed below. Carry Case and Strap P/N 2490 (included) allowing operation of all the buttons. A clear plastic cover protects the keypad while MPH-1 hose, bonded seals, o-ring kit, and teflon tape. Our test lead kit features high quality banana to MPH-1 hose, bonded seals, o-ring kit, and teflon tape. 600 Series banana test leads with rugged,...
Open the catalog to page 5All Ametek Calibration catalogs and technical brochures
-
PTC series
14 Pages
-
RTC series
15 Pages
-
Type T Deadweight Tester
8 Pages
-
HL Deadweight Tester
4 Pages
-
HK Deadweight Tester
2 Pages
-
RK Deadweight Tester
3 Pages
-
PK II
3 Pages
-
XP2i Data Recorder
6 Pages
-
ATMi
7 Pages
-
HPC50
6 Pages
-
Temperature Pressure Process
12 Pages
-
AMETEK Calibration Brochure
12 Pages
-
CrystalCalHP
7 Pages
-
Maritime Brochure
8 Pages
-
m1M Manual
4 Pages
-
m1M Data Sheet
4 Pages
-
CPF Brochure (D)
4 Pages
-
APM Advanced Pressure Module
6 Pages
-
HPC40 Series Calibrator
6 Pages
-
Product Overview Brochure
8 Pages
-
GaugeCalHP Manual
20 Pages
-
24 VDC Power Supply Manual
7 Pages
-
24 VDC Power Supply
4 Pages
-
30 Series
4 Pages
-
FastCalXP
9 Pages
-
Lab Reference Recorder
2 Pages