Group: AMETEK
Catalog excerpts

Fast, timesaving, and reliable Superior in speed and portability The CTC series is a fast dry-block that offers both interchangeable inserts, the MVI stability circuitry, and calibration software. Both speed and portability are superior to liquid baths. Dry-block calibrators do not require hazardous liquids and provide a wide temperature range. High flexibility You are not limited by fixed holes. Inter-changeable insertion tubes are used to match the diameter of your sensor-under-test. Wide temperature range The CTC series covers a wide temperature range from 33 to 1205°C (91 to 2200°F)....
Open the catalog to page 2
Easy-to-read Display Easy-to-use operation All instrument controls may be performed from the front panel. The heat source is positioned away from the panel. This design helps to protect the operator. The main functions on the CTC series are designed with one-key-one-function logic. This means that there are no sub-menus or difficult to remember multiple keystrokes necessary to access primary functions. The easy-to-read, backlit display features dedicated icons, which help in identifying instrument conditions and operational steps. Informative display and intuitive operation All models...
Open the catalog to page 3
The CTC is a very versatile calibrator series with many integrated Stability Indicator A bold checkmark on the display indicates that the calibrator has reached the desired set temperature and is stable. The operator may change the stability criteria and establish a greater sense of security in the calibration results. A convenient countdown timer is activated five minutes before the unit reaches stability. functions. Instrument setups The CTC series stores the complete instrument setup, including: engineering units, stability criteria, resolution, display contrast, slope (ramp) rate,...
Open the catalog to page 4
■ User specified settings Re-calibration/adjustments The CTC series has a very easy and straightforward procedure for re-calibration/adjustment. There is no need for a screwdriver or PC software. The only thing you need is a reliable reference thermometer. Place the probe in the calibrator and follow the instructions on the display. Support rod set The support rod can be mounted on all CTC calibrators. It is used to hold the sensor under test in its position while calibrating. Indcludes rod, sensor grip and fixture. Calibrate up to 24 sensors at a time Using the CTC together with the ASM...
Open the catalog to page 5
Physical Specifications Temperature Range Accuracy CTC-320 with internal ref. sensor. . . . . . . . . . . . . . . . ±0.5°C /±0.9°F Specification when using the internal reference. (Load 4 mm OD reference probe in the center of the insert). Stability CTC-320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.1°C / ±0.18°F Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. Settings Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 or 0.1 Units. . . . . . . . . . . . . ....
Open the catalog to page 6
AMETEK SENSORS. TEST 4 CALIBRATION
Open the catalog to page 7
Physical Specifications Temperature Range Accuracy CTC-1200 with internal ref. sensor. . . . . . . . . . . . . . . ±2.0°C /±3.6°F Stability CTC-1200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.1°C / ±0.18°F Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. Settings Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 or 0.1 Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . °C or °F Heating Time CTC-1200. . ....
Open the catalog to page 8
Inserts Inserts for CTC-320 B are made of aluminum. Inserts for CTC-650 B are made of brass. Inserts for CTC-1200 A are made of high-temperature steel alloy. All specifications on hole sizes are referring to the outer diameter of the sensor-under-test. The correct clearance size is applied in all predrilled inserts. Undrilled Inserts Part Numbers Part Numbers Part Numbers 1 Use insert code, when ordered as standard insert together with a calibrator. 2 CTC-1200A only - Remember to order matching insulation plugs. Use of other inserts may reduce performance of the calibrator. To get the best...
Open the catalog to page 9
Base Model Number CTC-650B with standard accessories, 230 VAC power with European power cord and insert: Pre-drilled 1x6 mm, Accredited certificate and carrying case AMETEK SENSORS. TEST 4 CALIBRATION
Open the catalog to page 10
124518 CTC-1200 Insulation plug (3 pcs) 7, 8, 9mm & 5/16in 124519 CTC-1200 Insulation plug (3 pcs) 10,11mm & 3/8, 7/16in # DANAK CAL P'V.HU 4U ENISO/IEC 17025 Laboratory accreditation AMETEK Sensors, Test & Calibration has two EN ISO/IEC 17025 accredited laboratories that issues accredited certificates in accordance with international standards. Laboratory accreditation is a reliable indicator of technical competence assuring customers the most accurate documentation. We believe in being clear about our capabilities, our accuracy, and about what you can expect from us. Because calibration...
Open the catalog to page 11All AMETEK Calibration Instruments catalogs and technical brochures
-
XP2i Pressure Gauge psi
5 Pages
-
PTC-125 Cooler
12 Pages
-
MTC 650A Spec Sheet
8 Pages
-
MTC 650A - Dry-block
8 Pages
-
PTC Series
13 Pages
-
mACal - mA Loop Calibrator
5 Pages
-
Crystal Pressure Fittings
13 Pages
-
CPF
4 Pages
-
AMETEK Calibration Brochure
12 Pages
-
Sanitary Sensors Brochure
4 Pages
-
30 series
4 Pages
-
JofraCloud
6 Pages
-
nVision Reference Recorder
9 Pages
-
DTI-1000 & STS-100/102
10 Pages
-
ETC Series - Dry-block
8 Pages
-
PTC-125 - Ultra Cooler
12 Pages
-
RTC-156/157 Dry-block calibrator
12 Pages
-
CTC Series - Dry-block
8 Pages
-
RTC-700 Dry-block calibrator
12 Pages
-
RTC-159 - Ultra Cooler
12 Pages
Archived catalogs
-
nVision Lab Brochure
7 Pages
-
DTI050 and STS-050
4 Pages
-
Type T - Deadweight tester
8 Pages
-
m1m Data Sheet
4 Pages
-
AMC910 - Signal calibrator
4 Pages
-
CSC101 - Signal Calibrator
4 Pages
-
CSC201 - Signal calibrator
4 Pages
-
HPC40 Series
7 Pages
-
ITC Series - Dry-block
8 Pages