1. Catalogs
  2. AMETEK Calibration Instruments
  3. JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet

JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet

JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet
1 / 14 PagesView full catalog

JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet

Product catalog summary
Overview: The document provides comprehensive information on the CTC Series Compact Temperature Calibrators, including models CTC-155, CTC-350, CTC-652, and CTC-660. These calibrators are designed for industrial temperature calibration, offering improved accuracy and efficiency. They are lightweight, portable, and suitable for both on-site and maintenance shop use.
Key Features:
  • Accuracy and Speed: The calibrators offer a 25% improvement in accuracy, with fast heating and cooling times and a short stabilization period.
  • Temperature Range: They cover a wide range from -25 to 660°C, suitable for most industrial applications.
  • Intelligent Accuracy: Equipped with liquid-filled sensors and an external reference sensor for enhanced precision.
  • Self Calibration: Allows internal sensor adjustment to match external reference readings.
  • Display and Operation: Features an informative color display with intuitive operation and quick access function keys.
Specifications:
  • CTC-155: Temperature range from -25 to 155°C, accuracy of ±0.3°C with internal sensor, and ±0.2°C with external sensor. Heating time is 13 minutes from 23 to 155°C.
  • CTC-350: Temperature range from 28 to 350°C, accuracy of ±0.45°C at 350°C with internal sensor, and ±0.25°C with external sensor. Heating time is 6 minutes from 23 to 350°C.
  • CTC-652: Temperature range from 28 to 650°C, with a heating time of 33 minutes and a cooling time of 48 minutes from 650 to 100°C.
  • CTC-660: Temperature range from 28 to 660°C, with a heating time of 18 minutes and a cooling time of 39 minutes from 660 to 100°C.
Additional Features:
  • MVI Technology: Ensures temperature stability by compensating for mains power variance.
  • Multi Sensor Calibration: Advanced algorithms and external sensors improve accuracy for multiple or large sensors.
  • Broad Range of Inserts: Offers various inserts to fit different sensor diameters.
  • Online Firmware Upgrade: Allows for easy updates via the manufacturer's website.
Environmental Conditions: All models operate within a temperature range of 0 to 50°C and can be stored at temperatures between -20 to 50°C. They support humidity levels from 5 to 90% Rh, non-condensing.
External Reference Sensors: Specifications for external reference sensors like the STS-120-A-935 and STS-200-A-970 are detailed, including their accuracy and stability.
Inserts: Inserts are available in metric and imperial sizes, with specific part numbers for each size, emphasizing the use of JOFRA inserts for optimal performance.
Ordering Information: Provides a guide on ordering, including model numbers, power supply options, mains power cable types, insert types, and calibration certificates.
HS System Calibration: Details on calibration with an accredited certificate under ISO 17025 standards for the C-Model, including accessories and standard delivery items.
Procedures and Standards: Calibration is performed in ISO 17025 accredited laboratories, ensuring technical competence and accurate documentation.
Accessories: Lists various accessories, including protective carrying cases, support rod sets, reference sensors, sensor grips, fixtures, heat shields, and cleaning brushes.
Contact Information: Provides contact details for AMETEK offices in various countries.
Conclusion: The CTC Series offers a comprehensive solution for industrial temperature calibration, combining precision, speed, and versatility with user-friendly features and robust design.
See more

Catalog excerpts

JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-2

Save Time, Save Money Best In Class Industrial Calibrator Fast Calibration The new generation CTC temperature calibrators All Jofra temperature calibrators feature a feature improved accuracy by as much as 25%. They purpose-dedicated temperature regulator, are now the most accurate industrial class tempera- which provides a very fast heating and cooling ture calibrator on the market. time, and a short stabilization time. Performing a three point temperature calibration procedure is fast and easy. Wide Temperature Range The CTC series covers a wide temperature range The CTC series is designed...

 Open the catalog to page 2
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-3

External Reference Sensor Self Calibration Each CTC calibrator has a C model that includes a signal input for an external reference sensor. The sensor improves the accuracy even more. Our external reference sensors have been developed to match each of the CTC models. Adjust the internal reference sensor to give the same readings as the external reference sensor by performing a Self Calibration. After the Self Calibration the calibrator can be used without the external reference sensor. Regular Self Calibration is needed to ensure the accuracy. The Self Calibration is simple and fast to perform...

 Open the catalog to page 3
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-4

Shows information about recalibration due status, hot and cold safety warnings, and date and time. Calibration Settings -Shows the calibration settings and stability criteria for the reference sensor. Can be accessed and changed directly in the display by use of the arrow keys. Calibration Status Shows current status of the calibrator, like heating or cooling, expected time to stability, or stability achieved. 30.00 Preset | Auto step | Switch Function Keys Informative Color Display and Intuitive Operation The CTC series is designed with an easy-to-read and very informative color display that...

 Open the catalog to page 4
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-5

■ Useful Features MVI - Mains Power Variance The CTC is a very versatile calibrator series with many integrated functions - you can run the calibration in four different ways. , ... Immunity improves temperature Set Function Preset Mode stability Unstable mains power supplies are a ma- jor contributor to calibration inaccuracies. Traditional temperature calibrators often become unstable in industrial environments where large electrical motors, heating elements, and other devices are periodically cycled on and off. The cycling of supply power can cause lower quality temperature regulators to perform...

 Open the catalog to page 5
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-6

Multi Sensor Calibration Plug and Play Reference Sensors Insert heat loss due to mass loading from multiple or large sensors can be a challenge for most dry-block calibrators. The CTCs advanced feedback algorithms combined with the external reference sensor effectively addresses these challenges and makes the accuracy even better. All STS reference sensors are plug and play as they contain information in the connectors memory chip: Sensor coefficients • Unique serial number • Temperature range • Calibration date • Calibration interval Broad Range of Inserts IRI - Intelligent Recalibration Information...

 Open the catalog to page 6
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-7

■ User Specified Settings Calibration Software Included Silent Mode Operation The CTC calibrator can be programmed to run in silent operation. This function is an advantage if calibrating in a laboratory or an office. If used in silent operation the calibrator is not using its full cooling potential. Online Firmware Upgrade Support Rod Set The support rod can be mounted on all CTC calibrators, and it is used to hold the sensor under test in its position while calibrating. Indcludes rod, sensor grip, and fixture. The CTC is supplied with our highly versatile calibration software JofraCal. All...

 Open the catalog to page 7
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-8

Specifications CTC-155 JOFRAW calibration §t\ Please note: All specifications are given with an ambient temperature 23°C/73.4°F ± 3°C/5.9°F and specified at 115 V/230 V. ★) In lower 30 mm incl. Stability, Uniformity, 12-month drift (typical), Hysteresis, Resolution, Load (Max 6 mm) and calibration laboratory uncertainty. ★ ★) Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. ★ ★★) Stability when exposed to maximum temperature for 100 hours. Stability will depend on actual use of the probe.

 Open the catalog to page 8
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-9

Specifications CTC-350 Temperature Temperature Range Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 to 350°C / 82 to 662°F Lowest calibration temperature. . . . . . . . . . ambient +5°C / 41°F Accuracy  CTC-350 With Internal Reference Sensor @ 350°C / 662°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.45°C /±0.81°F @ 200°C / 392°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.40°C /±0.72°F CTC-350 With External Reference Sensor STS-120-A-935 @ Full Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.25°C /±0.45°F...

 Open the catalog to page 9
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-10

Mains Power Voltage . . . . . . . . . . . . . 115 V (103-127) / 206 V (180-254) Max Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150 VA Frequency, US deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz ±3 Frequency, non US deliveries. . . . . . . . . . . . . . . 50 Hz ±3, 60 Hz ±3 Physical Specifications Dimension L x W x H. . . 248x148x390 mm / 9.76x5.83x15.35 in Weight CTC-652. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.0 kg / 19.8 lb Immersion Depth CTC-652. . . . . . . . . . . . . . . . . ....

 Open the catalog to page 10
JOFRA Compact Temperature Calibrator CTC 155-350-652-660 datasheet-11

Mains Power Voltage. . . . . . . . . . . . . . . . . . . . . . 115 V (90-127) / 230 V (180-254) Max Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150 VA Frequency, US deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz ±3 Frequency, non US deliveries. . . . . . . . . . . . . . . 50 Hz ±3, 60 Hz ±3 Physical Specifications Dimension L x W x H. . . 248x148x305 mm / 9.76x5.83x12.01 in Weight CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 kg / 13.4 lb Immersion Depth CTC-660. . . . . . . . . . . ....

 Open the catalog to page 11

All AMETEK Calibration Instruments catalogs and technical brochures

  1. PTC-125 Cooler

    12  Pages

  2. PTC Series

    13  Pages

  3. CPF

    4  Pages

  4. 30 series

    4  Pages

  5. JofraCloud

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.