HPC40 Series Calibrator psi 88.6 (3.49) ACCURACY • PRESSURE MEASUREMENT mA CONNECTIONS Ø 4 mm SHIELDED BANANA JACKS 0 to 30% of Range: ±(0.01% of Full Scale) 30 to 110% of Range: ±(0.035% of Reading) Vacuum* : ±(0.05% of Full Scale**) REMOTE PRESSURE MODULE CONNECTION 0 to 30% of Range: ±(0.015% of Full Scale) Vacuum* : ±(0.05% of Full Scale**) * Applies to 300 psi and lower ranges only. ** Full Scale is the numerical value of the positive pressure range. SENSOR DIAPHRAGM SURFACE 300 PSI psiA (Absolute Pressure with BARO Option) All absolute accuracies are equivalent to the gauge pressure accuracies, except as noted below. 30 psi Range: Gauge Accuracy + 0.005 psiA 100 psi Range: Gauge Accuracy + 0.002 psiA Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. All models indicate vacuum, but vacuum specification applies to 30, 100, and 300 psi models only. Not recommended for continuous use at high vacuum. Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use. 1/4 INCH MNPT ADAPTER 1/4 INCH MBSP ADAPTER ADDITIONAL SENSOR LENGTH WITH OPTIONAL FITTING ADAPTERS The BARO option allows you to toggle between gauge and absolute pressure. 5487. A HPC40 Series psi Data Sheet Page 1 of 7
Open the catalog to page 1
HPC40 Series Calibrator psi DIFFERENTIAL The Tare function canPRESSURE pressure measurement uncertainties. Requires the use of an equalizing valve. improve differential Full Scale Range of Both Sensors Unit is enabled in CrystalControl XXWithout tare function: ± (0.05% of static line pressure reading) PRESSURE SENSOR Wetted Materials: ( wrench tight) 316 stainless steel (finger tight) 316 stainless steel and Viton® (internal o-ring) Diaphragm Seal Fluid: Silicone Oil BAROMETRIC REFERENCE Accuracy: ± 0.00725(BARO) mbar Pressure Connection: Metal to metal cone seal; O-ring can be removed if...
Open the catalog to page 2
HPC40 Series Calibrator psi CURRENT & VOLTAGE MEASUREMENT mA CONNECTIONS Ø 4 mm SHIELDED BANANA JACKS Connection: 4 mm jacks Maximum Voltage: 45 VDC Current (mA) Input Accuracy: ±(0.015% of rdg + 0.002 mA) mA Range: 0 to 55 mA Percent Range: 0-20, 4-20, 10-50 Max Allowable Current: 60 mA Resolution: 0.001 mA or 0.01% Units: mA and % Input Resistance: < 17.2 Ω V oltage Burden @ 20mA: < 0.35 V V oltage Burden @ 50mA: < 0.86 V HART Resistor: 250 Ω Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. Inputs protected by a resettable fuse. mA...
Open the catalog to page 3
HPC40 Series Calibrator psi TEMPERATURE MEASUREMENT Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. Combine with part number 127387 for a -45 to 150°C temperature sensor. Contact us to add a calibration certificate. Resolution: 0.01 on all scales Units: °C, K, °F, R, Ω TCR: 0.003850 Ω/Ω/°C (IEC 60751) Wiring: 2-, 3-, and 4-wire support Connection: Lemo Plug, 1S Series, 304 insert configuration The proper selection of the RTD sensing element is very important as the error associated with this device is the majority of the overall...
Open the catalog to page 4
HPC40 Series Calibrator psi POWER Type Alkaline HPC40 Series complies with the Electromagnetic Compatibility and the Pressure Equipment Directives. Cell Voltage Battery Life: >12 hours non-sourcing Uses 4 alkaline AA (LR6) batteries. This HPC40 Series complies with the Australian requirements for the C-tick mark. The instrument was tested against AS/NZS 3548, C-tick EMC/EMI requirements. 12 mA >8 hours when sourcing Recharge Time: 16 hours* (Using Eneloop 2100 mA hr) * Charging is done through USB. DATA/COMMUNICATION Digital Interface: mini-USB ENCLOSURE Weight: 689 g (24.3 oz) Housing:...
Open the catalog to page 5
HPC40 Series Calibrator psi RANGE & RESOLUTION TABLE P/N (Add one digit of resolution for differential mode.) ORDERING INFORMATION BARO Option CPF * Fitting Kits Pump System ** Carrying Case ~ Full . . . . . . . (omit) Aluminum . . . . (omit) System B (pneumatic) -25 inHg to 30 psi. . . . . . . . . . . . . . . . . . . . . . . -BXX SAMPLE PART NUMBERS System B (pneumatic) -25 inHg to 580 psi . . . . . . . . . . . . . . . . . . . . . . -BHX HPC41-1KPSI. . . . . . . . . . . . . . . . . . . . . . . . . Single Sensor (1000 psi) HPC40 with a 1/4" NPT pressure fitting....
Open the catalog to page 6
HPC40 Series Calibrator psi PUMP SYSTEMS STANDARD DELIVERY All pump systems for the HPC40 Series include 1/4 NPT and BSP female fittings and a carrying case with custom insert. Additional fittings and accessories included with individual systems are listed below. MPH-1 hose, bonded seals, o-ring kit, and teflon tape. XXSystems B… BXX (T-965), BHX (T-975-CPF) MPH-1 hose, bonded seals, o-ring kit, and teflon tape. XXSystems C… CXX (T-620), CHX (T-620H-CPF) 600 Series MPH-1 hose, MPF-CAP, MPM-PLUG, bonded seals, and teflon tape. XXSystems D… DOX and DWX (P-018-CPF) COMPLIMENTARY PRODUCTS...
Open the catalog to page 7All AMETEK Calibration Instruments catalogs and technical brochures
-
XP2i Pressure Gauge psi
5 Pages
-
PTC-125 Cooler
12 Pages
-
MTC 650A Spec Sheet
8 Pages
-
MTC 650A - Dry-block
8 Pages
-
PTC Series
13 Pages
-
mACal - mA Loop Calibrator
5 Pages
-
Crystal Pressure Fittings
13 Pages
-
CPF
4 Pages
-
AMETEK Calibration Brochure
12 Pages
-
Sanitary Sensors Brochure
4 Pages
-
30 series
4 Pages
-
JofraCloud
6 Pages
-
nVision Reference Recorder
9 Pages
-
DTI-1000 & STS-100/102
10 Pages
-
ETC Series - Dry-block
8 Pages
-
PTC-125 - Ultra Cooler
12 Pages
-
RTC-156/157 Dry-block calibrator
12 Pages
-
CTC Series - Dry-block
8 Pages
-
RTC-700 Dry-block calibrator
12 Pages
-
RTC-159 - Ultra Cooler
12 Pages
Archived catalogs
-
nVision Lab Brochure
7 Pages
-
DTI050 and STS-050
4 Pages
-
Type T - Deadweight tester
8 Pages
-
m1m Data Sheet
4 Pages
-
AMC910 - Signal calibrator
4 Pages
-
CSC101 - Signal Calibrator
4 Pages
-
CSC201 - Signal calibrator
4 Pages
-
ITC Series - Dry-block
8 Pages