Enhanced UL Adapter™
2Pages

{{requestButtons}}

Catalog excerpts

Enhanced UL Adapter™ - 1

BROOKFIELD LABORATORY VISCOMETER ACCESSORIES ideal for low viscosity materials Reduces measuring range to as low as 1 cP, depending on viscometer used Simple attachment to a standard Brookfield Viscometer or DV3T Rheometer Small sample size: 16 mL Cylindrical geometry provides defined shear rates for detailed product analysis Removable cap of low density polyethylene can be considered disposable for one-time use if required Stainless steel parts are easily cleaned What's Included? Locating Channel Assembly Spindle (304 s/s) with universal coupling nut Collar assembly with thumbwheel Water Jacket Chamber Tube Tube End Caps (package of 6) Closed Tube and Spindle made from 316 s/s The Brookfield Enhanced UL Adapter is used with any standard Brookfield Viscometer and Rheometer to make accurate and reproducible measurements on low viscosity materials. Newtonian and non-Newtonian materials can be measured. It is most commonly used with the LV series instrument (at 60 rpm, these models have a full scale range of 1-10 cP with the UL Adapter). The UL Adapter consists of a precision cylindrical spindle rotating inside an accurately machined tube. Its rheologically correct cylindrical geometry provides extremely accurate viscosity measurements and shear rate determinations. The tube has a removable end cap which allows the open ended tube to be used in a beaker or tank. With the cap in place, the closed tube can be immersed in a temperature bath or used with the ULA-40Y water jacket for precise temperature control. Working temperature range is from 1°C to 65°C. Use Closed Tubes for higher temperature requirements

Open the catalog to page 1
Enhanced UL Adapter™ - 2

Quick & Easy Design Saves Time 3. Quick & easy attachment of spindle: Longer coupling nut for better grip and twist action to connect spindle to viscometer. Redesigned bracket for attaching ULA assembly to viscometer. Provides more clearance for finger grip on coupling nut. Quick & easy removal of chamber: Simply loosen thumbwheel, chamber slides down and out. Permits rapid testing of multiple samples by swapping out chambers. Choice of leaving spindle attached to viscometer or disconnecting spindle and removing it with chamber. Water jacket sleeve remains in place attached to viscometer...

Open the catalog to page 2

All AMETEK Brookfield catalogs and technical brochures

  1. ctx

    2 Pages

  2. DIN Adapter

    1 Pages

  3. Thermosel™

    2 Pages

Archived catalogs

  1. DIN Adapter

    1 Pages