1. Catalogs
  2. American Flow Control
  3. Series 2100 Resilient Seated Check Valve Sales

Series 2100 Resilient Seated Check Valve Sales

Series 2100 Resilient Seated Check Valve Sales

Series 2100 Resilient Seated Check Valve Sales

Product catalog summary
Construction Features:
  • Stainless Steel Pipe Plug: Allows installation of a pressure gauge.
  • Fusion-Bonded Epoxy Coating: Provides corrosion resistance for long service life.
  • No Leakage: Ensures no leakage at pressures above 5 psig.
  • Reversible Rubber-Encapsulated Ductile Iron Disc: Reduces closing time, eliminating the need for external levers or springs.
  • Ductile Iron Body: Offers greater strength and durability than gray cast iron.
  • No External Moving Parts: Suitable for buried service.
  • Unobstructed Flow Area: Free of pockets that can trap debris.
  • One Piece Construction: No O-rings, pins, or packing to wear out.
  • Resilient Seated Disc: Cycle tested over 2,000,000 cycles without damage.
  • Pressure Rated: 250 psig working pressure, 500 psig shell test pressure.
  • Rubber Bonnet Gasket: Provides a reusable O-ring-type seal.
  • Stainless Steel Fasteners: Enhance corrosion resistance.
Features/Benefits/Specifications:
  • Designed for use in drinking water, sewage, fire protection, irrigation, and backflow control systems.
  • Complies with ANSI/AWWA C508 standards.
  • Compact design with ductile iron body and bonnet.
  • Rated for 250 psig with no leakage at pressures above 5 psig.
  • Minimizes disc slam with a 35° disc travel.
  • Virtually maintenance-free with only one moving part.
Specifications:
  • Manufactured from ductile iron meeting ASTM A536.
  • Fusion-bonded epoxy coating on all ferrous surfaces.
  • Type 304 stainless steel fasteners.
  • Disc is reversible and encapsulated with EPDM rubber.
Installation and Maintenance:
  • Valves should be carefully unloaded and protected from elements.
  • Ensure valve and flange gasket surfaces are clean and free of damage.
  • Can be installed in horizontal or vertical pipelines with upward flow.
  • Do not install in vertical lines with downward flow.
  • Minimal maintenance required; inspect annually or as needed.
Hydrant Security Check Valve:
  • Available in a hydrant security configuration.
  • Connects easily to the MJ shoe of fire hydrants.
  • Rated at 250 psig with no leakage.
  • Compatible with any hydrant brand and can be installed on pre-existing hydrants.
See more

Catalog excerpts

Series 2100 Resilient Seated Check Valve Sales-1

AMERICAN FLOW CONTROL 3 16 SERIES 2100 RESILIENT SEATED CHECK VALVE FLOW CONTROL

 Open the catalog to page 1
Series 2100 Resilient Seated Check Valve Sales-2

CONSTRUCTION STAINLESS STEEL PIPE PLUG Allows installation of pressure gauge. FUSION-BONDED EPOXY COATING INSIDE AND OUT Helps provide corrosion resistance for long service life. STAINLESS STEEL FASTENERS Helps provide corrosion resistance. ● RUBBER BONNET GASKET Provides reusable O-ring-type seal. NO LEAKAGE At pressures above 5 psig. PRESSURE RATED 250 psig working pressure 500 psig shell test pressure RESILIENT SEATED DISC Cycle tested over 2,000,000 cycles without damage. REVERSIBLE RUBBERENCAPSULATED DUCTILE IRON DISC The 35°travel of the disc acts to reduce closing time which eliminates...

 Open the catalog to page 2
Series 2100 Resilient Seated Check Valve Sales-3

3”-16” SERIES 2100 RESILIENT SEATED CHECK VALVES FEATURES/BENEFITS/SPECIFICATIONS FEATURES The AMERICAN Flow Control Series 2100 is designed for use in drinking water, sewage and fire protection systems, as well as irrigation and backflow control systems. The valve complies fully with ANSI/AWWA C508. It is ideal for pump and lift stations. Its design is simple and durable and helps eliminate most long-term maintenance efforts associated with metal seated swing check valve designs. The Series 2100 features a compact ductile iron body and bonnet. Ductile iron has more than twice the strength of...

 Open the catalog to page 3
Series 2100 Resilient Seated Check Valve Sales-4

3”-12” SECTIONAL DRAWING/DIMENSIONS/PARTS LIST No. Part Name Ductile Iron Bonnet Bolts & Nuts Stainless Steel Bonnet Gasket Flanged Ends Body Ductile Iron Stainless Steel Pipe Plug Sq. Head Stainless Steel Backflushing Actuator NOTES: 1. Series 2100 Check Valves meets or exceed requirements of ANSI/AWWA C508. 2. Series 2100 has a 250 psig rated working pressure, 500 psig test pressure. 3. Bolt patterns of Class 125 flanged ends are in accordance with ANSI/ AWWA C110/A21.10 (ASME B16.1 Class 125). 4. Body and bonnet are coated with fusion-bonded epoxy coating in compliance with ANSI/AWWA C550....

 Open the catalog to page 4
Series 2100 Resilient Seated Check Valve Sales-5

3”-16” SERIES 2100 RESILIENT SEATED CHECK VALVES 14”-16” SECTIONAL DRAWING/DIMENSIONS/PARTS LIST No. Part Name Ductile Iron Bonnet Bolts & Nuts Stainless Steel Bonnet Gasket Flanged Ends Body Ductile Iron Stainless Steel Pipe Plug Sq. Head Stainless Steel Backflushing Actuator NOTES: 1. Series 2100 Check Valves meets or exceed requirements of ANSI/AWWA C508. 2. Series 2100 has a 250 psig rated working pressure, 500 psig test pressure. 3. Bolt patterns of Class 125 flanged ends are in accordance with ANSI/AWWA C110/A21.10 (ASME B16.1 Class 125). 4. Body and bonnet are coated with fusion-bonded...

 Open the catalog to page 5
Series 2100 Resilient Seated Check Valve Sales-6

INSTALLATION This information is provided as a recommendation to the customer for the proper installation and use of Series 2100 Resilient Seated Check Valves. 1. When valves are received, they should be unloaded carefully. Protect stored valves from the elements. Be sure to prevent undue damage in handling. 2. Make sure the valve and flange gasket surfaces are clean and free of damage. Clean the inside of the valve to remove all debris and/or contaminants that may affect performance or fluid quality. Check for free movement of the valve disc and inspect valve seal. Verify the direction of flow...

 Open the catalog to page 6
Series 2100 Resilient Seated Check Valve Sales-7

3”-16” SERIES 2100 RESILIENT SEATED CHECK VALVES SERIES 2100 HYDRANT SECURITY CHECK VALVE The AMERICAN Flow Control Series 2100 is available in a hydrant security check valve configuration. It incorporates many of the features of the standard Series 2100 Check Valve. Its proven, simple design makes it the solution to securing all makes and models of fire hydrants in a water system. The check valve is designed with MJ x Solid Gland ends. It connects easily to the MJ shoe of the fire hydrant and can be restrained. The valve comes with fusion-bonded epoxy coating inside and out and is furnished...

 Open the catalog to page 7
Series 2100 Resilient Seated Check Valve Sales-8

AMERICAN Flow Control Waterous Company P.O. Box 2727 Birmingham, AL 35202-2727 Phone: 800-326-8051 Fax: 800-610-3569 Email: [email protected] 125 Hardman Avenue South South St. Paul, MN 55075-2421 Phone: 888-266-3686 Fax: 800-601-2809 Email: [email protected] 2100 Check Valve Product Information Product literature may become outdated. AMERICAN is not responsible for out-of-date information, errors or omissions. Please contact AMERICAN for the most current product information. EOE/Minority/Female/Veteran/Disability

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.