The American Flow Control 5 1/4” B-62-B-5 Fire Hydrant complies with ANSI/AWWA C502 standards and is UL Listed and FM Approved in applicable configurations. It features a one-piece bronze operating nut with a removable pipe plug for lubrication, a top travel stop nut to limit rod travel, and a two-section high-tensile steel hydrant rod. The upper barrel is coated with an E-coat primer and a two-part polyurethane top coat for durability.

Construction Details:
The hydrant includes a stainless steel hydrant spring for quick drain closure, a rugged bronze drain lever, and stainless steel base bolts and nuts for corrosion resistance. The hydrant seat is made of bronze with a near-vertical machined seating surface and two drain ports. The hydrant valve is constructed with an epoxy-coated iron top and bottom and EPDM rubber, designed to minimize debris entrapment.

Features and Benefits:
The hydrant offers a 360° rotation of the upper nozzle section, a 200 psig working pressure, and a shell tested at 400 psig. It includes a lubrication chamber to seal operating threads from water and debris, and a top travel stop nut to prevent stem buckling. The hydrant's design allows for easy field replacement of damaged nozzles without pins or set screws.

Maintenance Recommendations:
Routine maintenance as outlined in AWWA Manual M-17 is recommended. Semiannual lubrication and inspection are advised to ensure ease of operation and reduce repair frequency. Dirt and debris can prevent proper closure and drainage, potentially damaging the main valve.

Design Criteria:
The hydrant features a compression-type main valve closure, a traffic feature for easy nozzle section rotation, and a hydrant valve with a vertical taper of 20° or less. The draining system is bronze and activated by the main operating rod, with drains closing completely after no more than three turns of the operating nut.

Contact Information:
AMERICAN Flow Control, P.O. Box 2727, Birmingham, AL 35202-2727, Phone: 800-326-8051, Email: [email protected]
Waterous Company, 125 Hardman Avenue South, South St. Paul, MN 55075-1191, Phone: 888-266-3686, Email: [email protected]
Website: www.american-usa.com
See more

Catalog excerpts

5 1/4" American-Darling B-62-B-5 Fire Hydrant-1

AMERICAN FLOW CONTROL 5 1/4” B-62-B-5 FIRE HYDRANT

 Open the catalog to page 1
5 1/4" American-Darling B-62-B-5 Fire Hydrant-2

Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. ONE-PIECE BRONZE OPERATING NUT Has a removable pipe plug to allow lubrication of operating threads. TOP TRAVEL STOP NUT Provides a positive limit to main rod travel. Eliminates contact of valve bottom with interior of base, thereby protecting coating. HYDRANT ROD Furnished in two sections of high-tensile steel. Upper section has bronze sleeve where it passes through housing O-rings. Upper and lower sections are connected by gray iron coupling using stainless steel pins. EPOXY...

 Open the catalog to page 2
5 1/4" American-Darling B-62-B-5 Fire Hydrant-4

NOTES DESCRIPTION Operating Nut Cover O-ring Housing O-ring Thrust Washer Pipe Plug Weather Cover Housing Cover Housing Cover Cap Screw Housing Cover Gasket Housing Gasket Housing Housing Bolt and Nut Upper Barrel Lower Barrel Hose Nozzle Hose Nozzle Seal Hose Nozzle Retainer Hose Nozzle Retainer Washer Hose Cap Hose Cap Gasket Hose Cap Chain S-Hook Pumper Cap Chain Pumper Nozzle Storz Nozzle Pumper Nozzle Seal Pumper Nozzle Retainer Pumper Nozzle Retainer Washer Pumper Cap Storz Nozzle Cap Pumper Cap Gasket Storz Cap Gasket Snap Ring Breakable Flange Base Flange Rod Coupling Coupling & Clip...

 Open the catalog to page 4
5 1/4" American-Darling B-62-B-5 Fire Hydrant-5

FEATURES AMERICAN Flow Control’s American-Darling 5-1/4 in. B-62-B-5 hydrant incorporates more than 100 years of experience in design, manufacture and field experience. This means dependable and efficient operation when needed. Introduced in 1962, the 5-1/4 in. B-62-B-5 hydrant is rated at 200 psig and is seat tested at 400 psig. This hydrant meets or exceeds all requirements of ANSI/AWWA C502 for dry-barrel hydrants. The 5-1/4 in. B-62-B-5 is manufactured with the features you expect from a high-quality fire hydrant. The allbronze seat and drain ring ensure that the 5-1/4 in. B-62-B-5 hydrant...

 Open the catalog to page 5
5 1/4" American-Darling B-62-B-5 Fire Hydrant-6

AMERICAN Flow Control Waterous Company P.O. Box 2727 Birmingham, AL 35202-2727 Phone: 800-326-8051 Fax: 800-610-3569 Email: [email protected] 125 Hardman Avenue South South St. Paul, MN 55075-1191 Phone: 888-266-3686 Fax: 800-601-2809 Email: [email protected] Product literature may become outdated. AMERICAN is not responsible for out-of-date information, errors or omissions. Please contact AMERICAN for the most current product information. EOE/Minority/Female/Veteran/Disability