1. Catalogs
  2. American aerospace controls
  3. Model 1005 AC Current Sensor

Model 1005 AC Current Sensor

Model 1005 AC Current Sensor

Product catalog summary
Overview: This document provides technical specifications for the A.C. Current Sensor Series 1005 by American Aerospace Controls Inc. It includes details on current output ranges, impedance, input current range, operating frequency, overload capacity, output voltage signal, accuracy, and environmental characteristics.
Specifications:
  • Current Output Range and Impedance: Various models are available with current output ranges from 0 to 2 Amps AC up to 0 to 300 Amps AC, with corresponding impedance values ranging from 25 K Ohms to 0.25 K Ohms.
  • Input Current Range: Refer to the provided table for specific ranges.
  • Operating Frequency: 50 to 60Hz.
  • Overload Capacity: Continuous overload of 200A for 2 to 100A ranges and 400A for 150 to 300A ranges.
Output Characteristics:
  • Voltage Signal: 0 to 5Vdc Full Scale (FS).
  • Accuracy: ±1% FS for 10A range and above, ±2% FS for 2A and 5A ranges.
  • Ripple: 100mV RMS typical.
  • Response Time: 80 milliseconds typical (10 to 90%).
  • Temperature Coefficient: ±0.04% FS/°C max, ±0.08% FS/°C max for 2 & 5A units.
  • Repeatability: ±0.1% FS.
  • Voltage Signal at Overload: 11Vdc max.
  • Voltage Signal Linear to: 6Vdc (120% FS).
Power Supply:
  • No external supply voltage required; the unit is self-excited.
Environmental and Physical Characteristics:
  • Operating Temperature Range: -20° to +70°C.
  • Storage Temperature Range: -55° to +85°C.
  • Isolation: Between input, output, and case.
  • Conductor Cable Voltage: 1.5KV max, 5KV with insulated cable.
  • Case: Molded plastic meeting UL Flammability Rating 94V-0.
  • Weight: 5 oz. max.
Terminals:
  • 4-40 screws with 3/8” center-to-center spacing, accepting wire sizes up to 14 AWG and wire lugs up to 9/32” wide. Maximum torque not to exceed 8 in-lbs.
Dimensions: Dimensions are provided in inches with tolerances of .XX ± .03 and .XXX ± .010.
See more

Catalog excerpts

Model 1005 AC Current Sensor-1

Dimensions in Inches, Tolerances: .XX ± .03 A.C. CURRENT SENSOR SERIES 1005 CURRENT RANGE AMPS AC OUTPUT IMPEDANCE K OHMS CURRENT RANGE AMPS AC OUTPUT IMPEDANCE K OHMS 0 to 5Vdc FS (Full Scale) ± 1% FS for 10A range and above ±2% FS for 2A and 5A ranges 100mV RMS typical 80m-sec typical See Table ±0.04% FS/°C max. ±0.08% FS/°C max. (2 & 5A units) ±0.1% FS 11Vdc max. 6Vdc (120% FS) None, Self Excited -20° to +70°C -55° to +85°C Input/Output/Case 1.5KV max. (5KV with Insul. Cable) Molded Plastic Meets UL Flammability Rating 94V- 0 5 oz. max. TERMINALS: 4-40 SCREWS, 3/8” CENTER TO CENTER SPACING, ACCEPTS WIRE SIZES UP TO 14 AWG AND WIRE LUGS UP TO 9/32” WIDE. MAXIMUM TORQUE NOT TO EXCEED 8 IN-LBS AAC Cage Code Ident. No. 15948 AAC American Aerospace Controls Inc., 570 Smith St, Farmingdale, NY 11735 Drawing Number website: www.a-a-c.com