REMOVAL OF VOLATILE ORGAN COMPOUNDS (VOC) THROUGH FILTRATION, CONCENTRATION AND COMBUSTION WITH REGENERATIVE HEAT RECOVERY
2Pages

{{requestButtons}}

Catalog excerpts

REMOVAL OF VOLATILE ORGAN COMPOUNDS (VOC) THROUGH FILTRATION, CONCENTRATION AND COMBUSTION WITH REGENERATIVE HEAT RECOVERY - 1

REMOVAL OF VOLATILE ORGAN COMPOUNDS (VOC) THROUGH FILTRATION, CONCENTRATION AND COMBUSTION WITH REGENERATIVE HEAT RECOVERY Customer: SESTRIERE VERNICI – stabilimento di Nichelino (TO) - Italy Product sector: paint production CONCENTRATION SECTION Air flow: 15000 Nm3/h Temperature air: ambiente S.O.V. Pollutants: toluol, xilolo, acetate, MEK Max concetration S.O.V.: 466 mg/Nm3 Max load S.O.V.: 7 kg/h Adsorbtion material: active carbon INCENERATOR SECTION Highest air flow to burn originates from rigeneration phase: 2000 Nm3/h Inlet middle temperature: 80 – 100 °C Houres of functionary: 8 hours par day Lowest temperature in combustion chamber: 750 °C Lowest standing time in combustion chamber: 0,6 sec 20035 Lissone – via Adamello, 9 – tel (0039) 039.48.34.98 – 24.56.105 – fax (0039) 039.46.12.86 e-mail: info@ventilazioneindustriale.it – sito web: www.ventilazioneindustriale.it Reg. Soc. Trib. Monza 54794 - R.E.A. Milano N.1444463 – C.F. e P.I. 02404270965

Open the catalog to page 1
REMOVAL OF VOLATILE ORGAN COMPOUNDS (VOC) THROUGH FILTRATION, CONCENTRATION AND COMBUSTION WITH REGENERATIVE HEAT RECOVERY - 2

EMISSION Air flow: 17000 Nm3/h Temperature: 40 – 45 °C Concentration max C.O.T.: <20 mg/Nm3 Concentration max CO : <10 mg/Nm3 Concentration max NOx: <25 mg/Nm3 20035 Lissone – via Adamello, 9 – tel (0039) 039.48.34.98 – 24.56.105 – fax (0039) 039.46.12.86 e-mail: info@ventilazioneindustriale.it – sito web: www.ventilazioneindustriale.it Reg. Soc. Trib. Monza 54794 - R.E.A. Milano N.1444463 – C.F. e P.I. 02404270965

Open the catalog to page 2

All AMBOSO catalogs and technical brochures

  1. ReCol System

    5 Pages