REMOVAL OF VOLATILE ORGAN COMPOUNDS (VOC) THROUGH FILTRATION, CONCENTRATION AND COMBUSTION WITH REGENERATIVE HEAT RECOVERY
2Pages
Catalog excerpts
REMOVAL OF VOLATILE ORGAN COMPOUNDS (VOC) THROUGH FILTRATION, CONCENTRATION AND COMBUSTION WITH REGENERATIVE HEAT RECOVERY Customer: SESTRIERE VERNICI – stabilimento di Nichelino (TO) - Italy Product sector: paint production CONCENTRATION SECTION Air flow: 15000 Nm3/h Temperature air: ambiente S.O.V. Pollutants: toluol, xilolo, acetate, MEK Max concetration S.O.V.: 466 mg/Nm3 Max load S.O.V.: 7 kg/h Adsorbtion material: active carbon INCENERATOR SECTION Highest air flow to burn originates from rigeneration phase: 2000 Nm3/h Inlet middle temperature: 80 – 100 °C Houres of functionary: 8 hours par day Lowest temperature in combustion chamber: 750 °C Lowest standing time in combustion chamber: 0,6 sec 20035 Lissone – via Adamello, 9 – tel (0039) 039.48.34.98 – 24.56.105 – fax (0039) 039.46.12.86 e-mail: info@ventilazioneindustriale.it – sito web: www.ventilazioneindustriale.it Reg. Soc. Trib. Monza 54794 - R.E.A. Milano N.1444463 – C.F. e P.I. 02404270965
Open the catalog to page 1EMISSION Air flow: 17000 Nm3/h Temperature: 40 – 45 °C Concentration max C.O.T.: <20 mg/Nm3 Concentration max CO : <10 mg/Nm3 Concentration max NOx: <25 mg/Nm3 20035 Lissone – via Adamello, 9 – tel (0039) 039.48.34.98 – 24.56.105 – fax (0039) 039.46.12.86 e-mail: info@ventilazioneindustriale.it – sito web: www.ventilazioneindustriale.it Reg. Soc. Trib. Monza 54794 - R.E.A. Milano N.1444463 – C.F. e P.I. 02404270965