1. Catalogs
  2. ALXION
  3. Motors wound for 330 Vac phase to phase
video corpo

Motors wound for 330 Vac phase to phase

Motors wound for 330 Vac phase to phase

Product catalog summary
Technical Characteristics Overview
1. Thermal Conditions:
  • Ambient temperature is set at 20°C.
  • Winding temperature rise is 120°C.
  • Stator housing is either in contact with ambient air or integrated with a metallic armature.
  • Stator housing is secured on a metallic frame with an area twice the cross-section of the housing.
2. Motor Specifications:
  • Motors are wound for 330 Vac phase to phase.
  • Rated speeds are available at 500 and 1500 rpm.
  • Continuous torque ranges from 14.6 to 47.4 N.m depending on the model.
  • Peak torque ranges from 55 to 220 N.m.
  • Rated power varies from 735 to 3850 W.
  • Inertia and weight increase with motor size.
3. Electrical Characteristics:
  • Phase resistance and inductance vary with motor type.
  • Electrical time constant ranges from 5.1 to 8.9 ms.
  • Back emf constant is consistent across models at specific speeds.
4. Cooling and Fluid Specifications:
  • Fluid input temperature should not be lower to avoid condensation.
  • Use softened glycol-added water or approved fluids for cooling.
  • Fluid-cooled motors have specific continuous torque and current ratings at 60°C and 140°C winding temperatures.
  • Fluid temperature rise and housing temperature are specified for different models.
  • Pressure drop and fluid flow rates are provided for each motor type.
5. Additional Data:
  • Power cable specifications are provided for each motor type.
  • Number of poles is consistent at 12 across models.
See more

Catalog excerpts

Motors wound for 330 Vac phase to phase-1

TECHNICAL CHARACTERISTICS Motors wound for 330 Vac phase to phase 145STK2M Rated speed Continuous torque Current at continuous torque NATURAL CONVECTION Peak torque 145STK8M 500 500 500 N.m (1) (2)(3) 145STK6M 500 rpm (1)(4) 145STK4M 1500 14.6 A 2.3 5.2 N.m 1500 26.4 3.7 9.2 55 1500 37.3 5 12.7 110 1500 47.4 6.4 15.7 165 220 Current at peak torque (2) A 10.2 23.1 17.8 45.5 27.3 68.3 35.6 91.1 Rated power (1) W 735 2032 1247 3134 1775 3480 2200 3850 Inertia 10-3kg.m² 1.28 2.24 3.19 4.14 Weight kg 6.2 10.4 14.5 18.7 Thermal time constant (1) s 1012 1399 1667 1866 Thermal resistance (1) °C / W 0.394 0.324 0.275 0.239 Phase resistance at 20°C (2) Phase inductance at I continuous 12.9 Electrical time constant (2) (2) V/rad.s 6.2 0.95 3.46 0.55 2.51 0.38 12.4 44.5 6.8 28.2 4.5 22.2 3.4 1.91 4.88 1.91 4.78 1.91 4.88 ms Back emf constant (line to line) 2.55 66.7 mH Power cable square section nxmm Power cable diameter 5.1 4.25 2 7.2 8.2 8.9 1.91 4x1.5 4x1.5 4x1.5 4x1.5 Ø8 Ø8 Ø8 Ø8 mm Number of poles 12 145STK2M (4) WINDING AT 60°C Fluid input temperature 145STK4M 145STK6M 145STK8M 22.8 45.3 67.6 90 N.m Current at continuous torque FLUID-COOLED MOTORS COMPLEMENTARY DATA FOR Continuous torque A (5)(6) 3.5 °C 8 6.3 20 15.6 9 22.8 20 12.1 20 29.8 20 Fluid temperature rise °C 5 5 7 8 Housing temperature °C < 30 < 30 < 30 < 30 Fluid f low l / mn 3 3 3 3 W 620 930 1220 1510 Losses Pressure drop Bar 4x1.5 4x4 4x1.5 4x4 Ø8 Ø8 Ø8 Ø11.1 Ø8 Ø11.1 145STK4M N.m WINDING AT 140°C Current at continuous torque FLUID-COOLED MOTORS COMPLEMENTARY DATA FOR (4) 4x1.5 145STK2M Continuous torque 0.3 4x1.5 mm Power cable diameter 0.2 nxmm2 Power cable square section Fluid input temperature 29.9 A (5)(6) 5.4 12.3 0.4 0.5 145STK6M 59.8 145STK8M 90 9.7 24 14 120 35.5 19 46.8 °C Housing temperature 20 20 20 20 °C Fluid temperature rise 8 8 10 12 °C 33 29 29 31 l / mn 3 5 5 5 Losses W 1532 2240 2950 3660 Pressure drop Bar 0.2 0.7 1 1.3 Fluid f low Power cable square section Power cable diameter nxmm 2 4x1.5 4x4 4x1.5 4x6 4x2.5 4x10 Ø8 mm 4x1.5 Ø8 Ø11.1 Ø8 Ø13.4 Ø9.6 Ø16.7 (1) Thermal conditions: Ambient temperature 20° C Winding temperature rise 120° C Stator housing in contact with the ambient air or integral on all its peripheral area with a metallic armature in contact with the ambient air. Stator housing secured on a metallic frame having an area equal to twice the cross section of the housing. (2) Cold motor at 20° C (3) See torque vs speed characteristics on : http://www.alxion.com/CFN (4) Torque at stall or low speed. (5) Fluid input temperature should not be lower for avoiding condensation inside the motor. (6) For cooling fluid, use softened gycol-added water or fluids approved for closed cooling circuits. Other speed characteristics are available, please contact us. 7

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.