Special Offers for GC laboratories - 23 Pages

Add to MyDirectIndustry favorites
Special Offers for GC laboratories

Catalog excerpts

special offers for gc laboratories → GC columns by Agilent Technologies → GC columns by PerkinElmer → GC columns by Restek → GC columns by SGE → GC columns by Thermo Scientific → Ferrule by SGE → Liners → Septa → Syringes → Vials & Caps by Altmann Analytik → Vials & Caps by PerkinElmer → Gas filters by Agilent Technologies → GC accessories Valid until February 29th 2016 altmann analytik gmbh & co. kg Rupert-Mayer-Straße 46, 81379 Munich, Germany phone +49 (0)89 72 48 05 90, fax +49 (0)89 72 48 05 91, info@analytics-shop.com, www.analytics-shop.com

 Open the catalog to page 1

gc columns by agilent technologies 1. GC columns Gas chromatography is considered as one of the most important chromatographic separation method. Through different interaction between stationary phase (column material) and mobile phase (carrier gas) the separation of t different analytes can be realized . The type and amount of sample that can be separated is dependent on the properties of the stationary phase such as inner diameter, length, packing material or the speed of the carrier gas. GC columns by Agilent Technologies DB-1: 100% polysiloxane phases are the most common phases. They...

 Open the catalog to page 2

gc columns by agilent technologies DB-624: DB-624 columns are suitable for the analysis of volatile pollutants and residual solvents. > recommended for the environmental analysis special offer DB-Wax: DB-Wax columns are characterized by a broad analytical compatibility. In addition to the use for fast GC with high sample throughput, they are also suitable for analytes with a low boiling point. > PEG > polar phase special offer

 Open the catalog to page 3

GC columns by SGE BP1: Classic 100% dimethylpolysiloxane phase suitable for a wide range of applications and for routine analysis. > nonpolar phase > low bleed special offer BP5: 5% phenyl / 95% dimethylpolysiloxane phase. > nonpolar phase > wide range of applications > low bleed special offer BPX5: 5% phenyl polysilphenylene-siloxane phase amongst others suitable for the analysis of pesticides in conjunction with MS-detection. > nonpolar and very inert > wide range of applications > low bleed special offer

 Open the catalog to page 4

BP5MS: 5% phenyl-polyphenyl-siloxane phase suitable for a wide range of applications for example trace analysis in conjunction with GC-MS. > nonpolar phase > low bleed special offer BP624/BPX-Volatiles: Cyanopropylphenyl-polysiloxane phase suitable for environmental analysis and highly volatile solvents. >polar phase special offer Cyanopropylphenyl- Polysiloxane BPX50: 50% phenyl polysilphenylene. Suitable for EPA analysis and pharmaceutical applications. > low bleed > medium polarity special offer

 Open the catalog to page 5

BP20: Polyethylene glycol phase. > standard WAX column > polar phase special offer Polyethylenglycol Phase Polyethylenglycol Phase BPX70: 70% cyanopropyl polysilphenylene-siloxane phase with long service life – also ideal for cis/trans separation. > FAME-analysis > polar phase special offer

 Open the catalog to page 6

2. Ferrules by SGE A ferrule is a small, tightly interlocking connector within the GC system. Often underestimated, the ferrule is actually of great importance. On one hand, the ferrule is a connection between the column and the inlet or detector system. On the other hand it is ensured by the ferrule that the GC column is positioned safely and is correctly held in the GC apparatus. Ferrules are available in various sizes, materials and shapes and can thus be optimally adapted to the respective GC column. Which material is most suitable for the application? What kind of connection are you...

 Open the catalog to page 7

Graphit / Vespel: special offer For Injectors& Detectors at atmospheric pressure For Injectors& Detectors at atmospheric pressure For Injectors& Detectors at atmospheric pressure For GC-MS Interface Connection For GC-MS Interface Connectionnection For GC-MS Interface Connection special offer QP5000/50050 Wide Bore MS Interface, QP2010Injector and QP2010 Standard MS Interface QP5000/50050 Wide Bore MS Interface, QP2010Injector and QP2010 Standard MS Interface QP5000/50050 Wide Bore MS Interface, QP2010Injector and QP2010 Standard MS Interface compatible with compatible with

 Open the catalog to page 8

compatible material with special offer Perkin Elmer For Injectors& Detectors at atmospheric pressure Perkin Elmer For Injectors& Detectors at atmospheric pressure Perkin Elmer For Injectors& Detectors at atmospheric pressure special offer for all Injectors & Detectors (not for 8000 Series, Focus, Trace/ Ultra GC) for all Injectors & Detectors (not for 8000 Series, Focus, Trace/ Ultra GC) Thermo Scientific for all Injectors & Detectors (not for 8000 Series, Focus, Trace/ Ultra GC) Thermo Scientific For all Focus, Trace/ Ultra injectors and detectors at atmospheric pressure (not for GCMS)...

 Open the catalog to page 9

special offer For GCMS & Detectors at atmospheric pressure - column IDs 0.1-0.25mm For GCMS & Detectors at atmospheric pressure - column IDs 0.32mm For GCMS & Detectors at atmospheric pressure - column IDs 0.53mm compatible with Varian/ Bruker Varian/ Bruker Varian/ Bruker compatible with special offer Perkin Elmer Perkin Elmer Thermo Scientific Thermo Scientific Varian / Bruker Varian / Bruker

 Open the catalog to page 10

SilTite Metal: special offer compatible with special offer Perkin Elmer Perkin Elmer compatible with special offer compatible with QP5000/50050 Standard MS Interface Starter Kit QP5000/50050 Standard MS Interface Starter Kit QP5000/50050 Wide Bore MS Interface, QP2010Injector and QP2010 Standard MS Interface Starter Kit QP5000/50050 Wide Bore MS Interface, QP2010Injector and QP2010 Standard MS Interface Starter Kit QP5000/50050 Wide Bore MS Interface, QP2010Injector and QP2010 Standard MS Interface Starter Kit

 Open the catalog to page 11

compatible with special offer Thermo Scientific For GC-MC Interface Connections (Starter Kit) Thermo Scientific For GC-MC Interface Connections (Starter Kit) Thermo Scientific For GC-MC Interface Connections (Starter Kit) Thermo Scientific Injector/MS (non-ISQ) Starter Kit Thermo Scientific Thermo Scientific compatible with special offer For GCMS connections Starter Kit - column IDs 0.1-0.25mm For GCMS connections Starter Kit - column IDs 0.32mm For GCMS connections Starter Kit - column IDs 0.53mm Injector/GCMS Starter Kit (not for 220, 1200, 2000, or 4000 MS systems)

 Open the catalog to page 12

All Altmann Analytik Gmbh & Co. KG catalogs and technical brochures