PID-AY5
2Pages

{{requestButtons}}

Catalog excerpts

PID-AY5 - 1

Technical specifications Version 2.0 PID-AY5 Photo Ionisation Detector Bottom View Side View Dimensions are in millimetres (+/- 0.1 mm). Use of socketed connection is required. Soldering or cutting the connection pins may permanently damage the sensor and void the warranty. Target gases Minimum Detection Level (ppb) Linear Range (ppm) Overrange (ppm) Sensitivity minimum range* Sensitivity typical range* Full stabilisation time Warm up time Offset Voltage (mV) Response Time (t90 sec) VOCs with ionisation potentials < 10.6 eV 1 20 20 60 mV/ppm 110 mV/ppm 5 minutes 5 seconds 40-100 4 Power Consumption Supply Voltage Output Signal 80 mW - 200 mW depending on supply voltage 3.2 to 5.5 VDC 0.040 to 2.85 V Temperature Range Temperature Dependence Relative Humidity Range Humidity Sensitivity -20oC to 60oC see chart 0 to 95% non-condensing Near zero (to 75%RH) Operating Life IS Approval 5 years (excluding replaceable lamp and electrode stack) (No additional circuitry or external fusing required for intrinsic safety) Onboard Filter Lamp Electrode Stack Weight Position Sensitivity Warranty Period Patent information T: +44 (0)1376 556700 To remove liquids and particulates User Replaceable. Expected life = 10,000 hours User Replaceable <8 grams None Electronics and Housing 24 Months, Lamp 12 months. Electrode and lamp are user replaceable. 10.6 eV lamp typical life 10,000 hours. US Pat 6,646,444. Japan Pat 3,793,757 *Gain numbers measured with isobutylene at room temperature and sea level. For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. or visit our website at “www.alphasense.com”

Open the catalog to page 1
PID-AY5 - 2

Technical specifications Version 2.0 Figure 2 shows the response curve of 20 sensors throughout the entire operating range. Sensors are linear throughout the entire range. Fig. 3 Sensitivity Temperature Dependence Figure 3 shows the mean and ±95% confidence intervals of the response of the sensors to 10 ppm isobutylene over the entire temperature range. The temperature response follows the ideal gas law PID-AY5 Replacement Parts/Consumables List Part Number Part Number Maintenance Kit, which includes: 2 ea Polishing Disc 2 ea 10 μm, Cloth, Bottom Filter 2 ea 1 μm, Teflon, Top Filter, Large...

Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2 Pages

  2. NO2-B43F

    2 Pages

  3. NO-B4

    2 Pages

  4. H2S-B4

    2 Pages

  5. CO-B4

    2 Pages

  6. PID-AR5

    2 Pages

  7. PID-A15

    2 Pages

  8. PID-AH5

    2 Pages

  9. SO2-D4

    2 Pages

  10. PID-AH2

    2 Pages

  11. CH-D3

    2 Pages

  12. O2-G2

    2 Pages

  13. NO2-D4

    2 Pages

  14. NO-D4

    2 Pages

  15. IRM-AT

    2 Pages

  16. H2S-D4

    2 Pages

  17. PH3-BE

    2 Pages

  18. OPC-R2

    2 Pages

  19. CL2-D4

    2 Pages

  20. CO-D4X

    2 Pages

  21. SOH-A2

    4 Pages

Archived catalogs

  1. CO-CE

    2 Pages

  2. CO-BX

    2 Pages

  3. CO-BF

    2 Pages

  4. CO-AF

    2 Pages

  5. CO-AE

    2 Pages

  6. VOC Sensor

    2 Pages

  7. SOH-A2

    4 Pages

  8. CO-AX

    2 Pages

  9. Dual Sensor

    4 Pages

  10. COH-A2

    4 Pages

  11. CO-A4

    2 Pages

  12. CO-B4

    2 Pages

  13. H2S-A4

    2 Pages

  14. H2S-B4

    2 Pages

  15. NO-A4

    2 Pages

  16. NO-B4

    2 Pages

  17. NO2-A4

    2 Pages

  18. NO2-B4

    2 Pages

  19. O3-A4

    2 Pages

  20. O3-B4

    2 Pages

  21. PID-A1

    2 Pages

  22. PID-AH

    2 Pages

  23. SO2-A4

    2 Pages

  24. SO2-B4

    2 Pages

  25. CO2-D1

    2 Pages