Performance Specifications
Sensitivity ranges from -200 to -650 nA/ppm at 2ppm NO2. The response time (t90) from zero to 2ppm NO2 is less than 80 seconds. Zero current in zero air at 20°C ranges from -80 to +80 nA. Noise is ±2 standard deviations, equivalent to 15 ppb. The sensor's range is up to 20 ppm NO2, with a linearity error of less than ±0.5 ppb at full scale. The overgas limit is 50 ppm for a stable response to gas pulses.
Lifetime and Drift
The zero drift is 0 to 20 ppb equivalent change per year in lab air. Sensitivity drift is between -20% to -40% change per year. The operating life is over 24 months until the signal reaches 50% of its original value.
Environmental Conditions
Sensitivity at -20°C is 60% to 80% of the output at 20°C, and at 40°C, it is 95% to 115%. Zero current at -20°C is 0 to 25 nA, and at 40°C, it is -10 to 50 nA.
Cross-Sensitivity
The O3 filter capacity is greater than 500 ppm.hr at 0.5ppm O3. Sensitivity to other gases includes H2S (< -80%), NO (< 5%), Cl2 (< 100%), SO2 (< -3%), CO (< -3%), H2 (< 0.1%), C2H4 (< 0.1%), NH3 (< 0.1%), and CO2 (< 0.1%). Halothane sensitivity is not determined.
Key Specifications
The temperature range is -30 to 40°C, pressure range is 80 to 120 kPa, and humidity range is 15% to 85% RH continuously. The storage period is 6 months at 3 to 20°C in a sealed pot. The recommended load resistor is 33 to 100 Ω, and the sensor weighs less than 13 grams.
Figures and Diagrams
Figures illustrate the temperature dependence of sensitivity and zero output variation due to temperature changes. The NO2-B43F sensor shows excellent resolution at the ppb level, suitable for outdoor air environmental testing. The use of the Alphasense ISB circuit reduces noise to 15 ppb, with potential for further digital smoothing.
Additional Notes
All sensors are tested under ambient conditions unless otherwise stated. Customers should verify sensor suitability under their own conditions. Disposal instructions are provided by Alphasense or its distributors.
See more

Catalog excerpts

NO2-B43F-1

Nitrog Dioxide ogen NO2-B43F Nitrogen Dioxide Sensor 4-Electrode 4-Electrode Technical specifications Version 1.0 NO2-B43F Nitrogen Dioxide Sensor – 4-Electrode Figure 1 NO2-B43F Schematic Diagram All dimensions in millimetres (± 0.15mm) Top Top View View Bottom View Bottom View SideSide View View ERFORMANCE Sensitivity nA/ppm at nA/ppm at 2ppm NO -200 to -650 Performance Sensitivity 2ppm NO2 Response time t90 (s) from zero to 2ppm NO < 80 zero to at 20°C Response time current (s) fromnA in zero air2ppm NO2 t90 Zero -80 to +80 Zero current Noise nA in zero air at 20°C ±2 standard deviations (ppb equivalent) 15 Range ppm NO limit of performance warranty 20 Noise* ±2 standard deviations (ppb equivalent) Linearity ppm NO limiterrorperformanceat zero and 20ppm ppb of at full scale, linear warranty < ± 0.5 Range 2 Overgas limit NO maximum ppm for stable response to gas pulse 50 Linearity ppb error at full scale, linear at zero and 20ppm NO2 Tested with Alphasense ISB low noise circuit Overgas limit maximum ppm for stable response to gas pulse 2 Zero drift ppb equivalent change/year in lab air * Tested with Alphasense ISB low noise circuit Sensitivity drift Operating ppb life % change/year in lab air, monthly test months until 50% original signal (24-month equivalent change/year in lab air warranted) Zero drift Sensitivity drift % change/year in lab air, monthly test Sensitivity @ -20°C % 60 to Environmental Operating life months until(output @ -20°C/output @ 20°C) @ 2ppm NO warranted)80 50% original signal (24 month Sensitivity @ 40°C Zero @ -20°C Zero @ 40°C NVIRONMENTAL Sensitivity @ -20°C Cross-sensitivity Sensitivity @ O40°C H S Zero @ -20°C NO Zero @ 40°CCl 3 ROSS ENSITIVITY (% output @ -20°C/output @ 20°C) @ 2ppm NO2 filter capacity @ hrs) @ 0.5ppm O < (% output (ppm 40°C/output @ 20°C) @ 2ppm NO2500 sensitivity % measured gas @ 5ppm H S < -80 nA sensitivity % measured gas @ 5ppm NO <5 nA sensitivity % measured gas @ 5ppm Cl < 100 3 SO2 sensitivity % measured gas @ 5ppm SO2 CO capacity (ppm.hr) sensitivity % measured gas @ 5ppm CO Filter @ 0.5ppm O3 H2 sensitivity % measured gas @ 100ppm H2 sensitivity sensitivity % measured gas @ 100ppm % measured gas @ 5ppm H2H S C2H4 C2 4 sensitivity sensitivity % measured gas @ 20ppm % measured gas @ 5ppm NO NH3 NH3 CO2 CO sensitivity sensitivity % measured gas @ 5% volume Cl22 % measured gas @ 5ppm Halothane % measured gas @ 5ppm sensitivity sensitivity % measured gas @ 100ppm Halothane SO O3 H2S NO Cl2 SO2 2 CO sensitivity % measured gas @ 5ppm CO Temperature range °C Key Specifications H2 sensitivity % measured gas @ 100ppm H2 Pressure range kPa C2H4 sensitivity % measuredcontinuous@ 100ppm C2H4 Humidity range % rh gas Storage period months @ 3 20°C 20ppm pot) NH3 sensitivity % measured gas to @ (stored in sealedNH3 Load resistor � (ISB circuit is recommended) CO2 sensitivity % measured gas @ 5% Vol CO2 Weight g Halothane sensitivity % measured gas @ 100ppm Halothane EY SPECIFICATIONS Temperature range °C T: +44 (0)1376 556700 E: [email protected] W: www.alphasense.com Pressure range kPa For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. or visit our webs

 Open the catalog to page 1
NO2-B43F-2

Technical specifications Version 1.0 Perf erformance Data NO2-B43F Performance Data Figure 1 Sensitivity Temperature Dependence Perf erformance Data NO2-B43F Performance Data Figure 2 Sensitivity Temperature Dependence 120 % output (referenced to 20oC) % output (referenced to 20oC) % output (referenced to 20oC) Figure 2 Sensitivity Temperature Dependence 110 Figure 2 shows the temperature dependence of sensitivity at 2ppm NO2. This data is taken from a typical batch ofshows the sensors. Figure 2 Figure 1 shows the temperature dependence of temperature dependence of sensitivity 2ppm NO . sensitivity...

 Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2  Pages

  2. NO-B4

    2  Pages

  3. H2S-B4

    2  Pages

  4. CO-B4

    2  Pages

  5. PID-AR5

    2  Pages

  6. PID-A15

    2  Pages

  7. PID-AY5

    2  Pages

  8. PID-AH5

    2  Pages

  9. SO2-D4

    2  Pages

  10. PID-AH2

    2  Pages

  11. CH-D3

    2  Pages

  12. O2-G2

    2  Pages

  13. NO2-D4

    2  Pages

  14. NO-D4

    2  Pages

  15. IRM-AT

    2  Pages

  16. H2S-D4

    2  Pages

  17. PH3-BE

    2  Pages

  18. OPC-R2

    2  Pages

  19. CL2-D4

    2  Pages

  20. CO-D4X

    2  Pages

  21. SOH-A2

    4  Pages

Archived catalogs

  1. CO2-D1

    2  Pages

  2. SO2-B4

    2  Pages

  3. SO2-A4

    2  Pages

  4. PID-AH

    2  Pages

  5. PID-A1

    2  Pages

  6. O3-B4

    2  Pages

  7. O3-A4

    2  Pages

  8. NO2-B4

    2  Pages

  9. NO2-A4

    2  Pages

  10. NO-B4

    2  Pages

  11. NO-A4

    2  Pages

  12. H2S-B4

    2  Pages

  13. H2S-A4

    2  Pages

  14. CO-B4

    2  Pages

  15. CO-A4

    2  Pages

  16. COH-A2

    4  Pages

  17. Dual Sensor

    4  Pages

  18. CO-AX

    2  Pages

  19. SOH-A2

    4  Pages

  20. VOC Sensor

    2  Pages

  21. CO-AE

    2  Pages

  22. CO-AF

    2  Pages

  23. CO-BF

    2  Pages

  24. CO-BX

    2  Pages

  25. CO-CE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.