Product catalog summary
Performance Specifications
The sensor requires a maximum power of 5.0 VDC and 60 mA with a 50% duty cycle source drive. It operates at a minimum voltage of 2.0 VDC and 20 mA. The source drive frequency is 3 Hz. The active output in nitrogen (N2) ranges from 4 to 7 mV peak-to-peak at 3 Hz, while the reference output ranges from 2 to 5 mV. The response time (t90) is less than 40 seconds at 20°C, and the warm-up time to final zero is less than 30 seconds, with full specification achieved in under 30 minutes.

Lifetime
The Mean Time Between Failures (MTBF) is greater than 5 years.

Key Specifications
The sensor includes an integral thermistor for temperature signal with an operating range from -20°C to +50°C and storage range from -40°C to +75°C. It can handle humidity from 0 to 95% relative humidity, non-condensing. All dimensions are in millimeters with a tolerance of ± 0.15mm.

Technical Specifications
The sensor is tested under ambient conditions with a 47-ohm load resistor. Customers are advised to test the sensors under their own conditions to ensure suitability. Disposal instructions should be obtained from the manufacturer or distributor.

Pin Out Details
The sensor includes several pins for lamp return, lamp +5V, detector output, reference output, thermistor output, and OV supply. Antistatic precautions should be taken when handling, and pins should not be cut or soldered directly.

Application Range and Accuracy
The sensor is suitable for various applications with different ranges and accuracies. For Indoor Air Quality (IAQ), it measures 0 to 5000 ppm with 1% accuracy. For safety applications, it measures 0 to 5% volume with 1.5% accuracy. For combustion, it measures 0 to 20% volume with 2.5% accuracy. Process control applications are also supported.

Figures and Graphs
Figures illustrate the Beer-Lambert performance, linearisation, and resolution. The sensor's response from 0 to 5000 ppm CO2 is close to the theoretical curve predicted by the Beer-Lambert Law, indicating that custom linearisation is unnecessary. The sensor achieves excellent resolution and noise performance at 1000 ppm CO2 through design improvements rather than expensive components.
See more

Catalog excerpts

IRC-AT Carbon Dioxide-1

IRC-AT CARBON DIOXIDE IRC-A C-AT DIOXIDE INFRARED SENSOR Thermopile Detector Technical Specification Figure 1 IRC-AT Schematic Diagram Top View Pin out details: 1. Lamp return 2. Lamp +5V 3. Not connected 4. Detector output. 5. Reference output 6. Thermistor output 7. OV supply Bottom View Side View Notes: 1. Dimensions without tolerances are nominal 2. Recommended PCB socket: Wearnes Cambion Ltd. code: 450-3326-01-06-00 3. Weight: 15g 4. Use antistatic precautions when handling 5. Do not cut pins 6. Do not solder directly to pins PERFORMANCE Maximum Power Requirements Minimum Operating Voltage Source Drive Frequency Active Output in N2 (peak-to-peak) Reference Output in N2 (peak-to-peak) Response Time (t90) Warm-up Time 5.0 VDC, 60 mA max. (50% duty cycle source drive) 2.0 VDC, 20 mA max. (50% duty cycle source drive) 3 Hz 4 to 7 mV @ 3 Hz, 50% duty cycle 2 to 5 mV @ 3 Hz, 50% duty cycle < 40 s @ 20°C ambient To final zero ± 100 ppm: < 30 s @ 20°C To specification: < 30 minutes @ 20°C LIFETIME MTBF KEY SPECIFICATIONS Temperature Signal Operating Temperature Range Storage Temperature Range Humidity Range Integral thermistor (NTC, R25 = 100KΩ B= 3940 K) -20°C to +50°C (linear compensation from 0 to 40°C) -40°C to +75°C 0 to 95% rh non-condensing Range (Application) Accuracy (%FS, using universal linearisation coefficients) Full Scale Resolution (ppm) Full Scale Repeatability (ppm) Span Universal Universal calibration lin. coeff. b lin. coeff. c conc. At the end of the product’s life, do not dispose of any electronic sensor, component or instrument in the domestic waste, but contact the instrument manufacturer, Alphasense or its distributor for disposal instructions. NOTE: all sensors are tested at ambient environmental conditions, with 47 ohm load resistor, unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements. Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley. CM77 7AA. UK Telephone: +44 (0) 1376 556 700 Fax: +44 (0) 1376 335 899 E-mail: [email protected] Website: www.alphasense.com

 Open the catalog to page 1
IRC-AT Carbon Dioxide-2

IRC-A Perf C-AT erformance Data IRC-AT Performance Data Figure 2 Beer Lambert Performance 0.16 Typical response from 0 to 5000ppm CO2. The fit is very close to the theoretical curve, predicted by the Beer-Lambert Law. 0.12 0.10 0.08 0.06 Model fit using standardised coefficients Custom linearisation is not necessary with the IRC-AT. Using universal linearisation constants, repeatability between cells is very good, allowing easy implementation. For an IAQ application, a zero and then single calibration at 4000ppm CO2 gives the error shown above: typically less than ± 40ppm from 0 to 4500ppm. Excellent...

 Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2  Pages

  2. NO2-B43F

    2  Pages

  3. NO-B4

    2  Pages

  4. H2S-B4

    2  Pages

  5. CO-B4

    2  Pages

  6. PID-AR5

    2  Pages

  7. PID-A15

    2  Pages

  8. PID-AY5

    2  Pages

  9. PID-AH5

    2  Pages

  10. SO2-D4

    2  Pages

  11. PID-AH2

    2  Pages

  12. CH-D3

    2  Pages

  13. O2-G2

    2  Pages

  14. NO2-D4

    2  Pages

  15. NO-D4

    2  Pages

  16. IRM-AT

    2  Pages

  17. H2S-D4

    2  Pages

  18. PH3-BE

    2  Pages

  19. OPC-R2

    2  Pages

  20. CL2-D4

    2  Pages

  21. CO-D4X

    2  Pages

  22. SOH-A2

    4  Pages

Archived catalogs

  1. CO2-D1

    2  Pages

  2. SO2-B4

    2  Pages

  3. SO2-A4

    2  Pages

  4. PID-AH

    2  Pages

  5. PID-A1

    2  Pages

  6. O3-B4

    2  Pages

  7. O3-A4

    2  Pages

  8. NO2-B4

    2  Pages

  9. NO2-A4

    2  Pages

  10. NO-B4

    2  Pages

  11. NO-A4

    2  Pages

  12. H2S-B4

    2  Pages

  13. H2S-A4

    2  Pages

  14. CO-B4

    2  Pages

  15. CO-A4

    2  Pages

  16. COH-A2

    4  Pages

  17. Dual Sensor

    4  Pages

  18. CO-AX

    2  Pages

  19. SOH-A2

    4  Pages

  20. VOC Sensor

    2  Pages

  21. CO-AE

    2  Pages

  22. CO-AF

    2  Pages

  23. CO-BF

    2  Pages

  24. CO-BX

    2  Pages

  25. CO-CE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.