Overview: The H2S-D4 Hydrogen Sulfide Sensor is a miniature sensor designed for detecting hydrogen sulfide gas. It is available in a three-pin version coded H2S-D1. The sensor is manufactured by Alphasense Ltd.
Technical Specifications:
  • Temperature Range: -30 to 50°C
  • Pressure Range: 80 to 120 kPa
  • Humidity Range: 15 to 90% rh
  • Storage Period: 6 months at 3 to 20°C in a sealed pot
  • Load Resistor: 10 to 47 Ω (recommended)
  • Weight: Less than 2 grams
Performance:
  • Sensitivity: 110 to 170 nA/ppm at 20ppm H2S
  • Response Time: Less than 25 seconds from zero to 20ppm H2S
  • Zero Current: Less than ±1 ppm equivalent in zero air
  • Resolution: Less than 0.2 ppm equivalent RMS noise
  • Range: 100 ppm H2S limit of performance warranty
  • Linearity: Less than ±6 ppm error at full scale
  • Overgas Limit: 200 ppm maximum for stable response
Environmental Impact: The sensor's performance is affected by temperature and humidity. Continuous exposure to high humidity and temperature can affect the sensor's electrolyte volumes, but it can recover under normal conditions.
Cross Sensitivity: The sensor shows varying sensitivity to other gases such as NO2, Cl2, NO, SO2, CO, H2, C2H4, and NH3, with specific percentage sensitivities provided for each.
Figures and Data: The document includes figures showing sensitivity temperature dependence, zero temperature dependence, and long-term stability. These figures illustrate the sensor's performance variations under different conditions.
Disposal Instructions: At the end of the product's life, the sensor should not be disposed of in domestic waste. Contact Alphasense or its distributor for proper disposal instructions.
Note: All sensors are tested under ambient conditions unless otherwise stated. Customers are advised to test the sensors under their own conditions to ensure suitability for their requirements.
See more

Catalog excerpts

H2S-D4-1

echnical Specification echnical Specification H2S-D4 Hydrogen Sulfide Sensor Technical specifications Version 1.0 Miniature Size H2S-D4 Hydrogen Sulfide Sensor – Miniature Size Figure 1 H2S-D4 Schematic Diagram Bottom Side View Bottom View View Side View A three pin on request, is available on request, coded H2S-D1 version coded H2S-D1. Dimensions are in millimetres (± 0.1 mm). A three pin version is available PERFORMANCE Sensitivity Sensitivity Performance Response time Response time ZeroZero current current Resolution Resolution Range Range Linearity Linearity Overgas limit Overgas limit nA/ppm 20ppm H2S 110 to 170 nA/ppm 20ppm H S 110 to 170 < 25 t90 (s) from zero to 20ppm H2S t90 (s) from zero to 20ppm H S < 25 ppm equivalent in air air zero < ±1 ppm equivalent in zero <±1 RMS noise (ppm equivalent) < 0.2 RMS noise (ppm equivalent) < 0.2 ppm H2S limit of performance warranty 100 100 ppm H S limit of performance warranty ppm error full scale, linear linear at zero S <±6 < ±6 ppm erroratat full scale,at zero and 20ppm Hand 20ppm H2S maximum ppm for for stable response maximum ppm stable response to gas pulse to gas 200 pulse 200 2 Lifetime LIFETIME ZeroZero drift drift Sensitivity drift Sensitivity drift Operating life Operating life ppm equivalent change/year in lab air < 0.2 ppm equivalent change/year in lab air % change/year in lab air, monthly test <3 % change/year in lab air, monthly test months until 80% original signal (24-month warranted) > 18 months until 80% original signal (24 month warranted) Environmental ENVIRONMENTAL Sensitivity @ -20°C Sensitivity @ 50°C Sensitivity @ -20°C Zero @ -20°C Sensitivity @ 50°C Zero @ 50°C Cross Sensitivity CROSS SENSITIVITY Zero @ -20°C ZeroNO sensitivity @ 50°C 2 Cl2 sensitivity sensitivity NO2NO sensitivity SO2 sensitivity Cl2 sensitivity CO sensitivity NO H sensitivity sensitivity 2 SO2C2Hsensitivity sensitivity 4 sensitivity CO NH3sensitivity ppm equivalent change from20°C ppm equivalent 10ppm from 20°C % measured gas @ change NO 2 % measured gas @ 10ppm Cl2 % measured gas @ 50ppm NO measured gas @ 10ppm NO2 % measured gas @ 20ppm SO measured gas @ 10ppm Cl22 % measured gas @ 400ppm CO measured gas @ 400ppm H % measured gas @ 50ppm NO 2 measured gas @ 400ppm % measured gas @ 20ppm SO2 C2H4 % measured gas @ 400ppm CO NH3 measured gas @ 20ppm % % % % % H2 sensitivity % measured gas @ 400ppm H2 °C C2HTemperature range% measured gas @ 400ppm C2H4 4 sensitivity Pressure range kPa NH3 sensitivity % measured gas @ 20ppm NH3 Humidity range Storage period SPECIFICATIONSLoad resistor Temperature range Weight Pressure range Humidity range Storage period Load resistor Weight % rh (see note below) months @ 3 to 20°C (stored in sealed pot) � (recommended) °C g kPa %rh (see note below) months @ 3 to 20°C (stored in sealed pot) Ω (recommended) g o Note: Above 85% [email protected] W: www.alphasense.com For further information warranted. Where such exposure occurs the any other T: +44 (0)1376 556700 E: rh and 40 C a maximum continuous exposure period of 10 days ison the performance of this sensor, on other sensors in the range orsensor will subject, please contact Alphasense Ltd. or several days. recover normal electrolyte volumes when allowed to rest at lower %rh and temperature levels forvisit ou

 Open the catalog to page 1
H2S-D4-2

Technical specifications Version 1.0 Perf erformance Data H2S-D4 Performance Data Figure 1 Sensitivity Temperature Dependence Figure 2 Sensitivity Temperature Dependence Perf erformance Data H2S-D4 Performance Data % ppm) % Output (referenced to (referenced to 20oC) % Zero output, Zero output, referenced to 20oCppm) to 20ppm) referenced to 20oC (equivalent (equivalent oC (equivalent Output (referenced to 20oC)Output 20oC) Zero output, referenced Output (nA/ppm) (nA/ppm) Output Output (nA/ppm) Technical Specification tion Tecechnical Specifica T hnical Specification Figure 2 Sensitivity Temperature...

 Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2  Pages

  2. NO2-B43F

    2  Pages

  3. NO-B4

    2  Pages

  4. H2S-B4

    2  Pages

  5. CO-B4

    2  Pages

  6. PID-AR5

    2  Pages

  7. PID-A15

    2  Pages

  8. PID-AY5

    2  Pages

  9. PID-AH5

    2  Pages

  10. SO2-D4

    2  Pages

  11. PID-AH2

    2  Pages

  12. CH-D3

    2  Pages

  13. O2-G2

    2  Pages

  14. NO2-D4

    2  Pages

  15. NO-D4

    2  Pages

  16. IRM-AT

    2  Pages

  17. PH3-BE

    2  Pages

  18. OPC-R2

    2  Pages

  19. CL2-D4

    2  Pages

  20. CO-D4X

    2  Pages

  21. SOH-A2

    4  Pages

Archived catalogs

  1. CO2-D1

    2  Pages

  2. SO2-B4

    2  Pages

  3. SO2-A4

    2  Pages

  4. PID-AH

    2  Pages

  5. PID-A1

    2  Pages

  6. O3-B4

    2  Pages

  7. O3-A4

    2  Pages

  8. NO2-B4

    2  Pages

  9. NO2-A4

    2  Pages

  10. NO-B4

    2  Pages

  11. NO-A4

    2  Pages

  12. H2S-B4

    2  Pages

  13. H2S-A4

    2  Pages

  14. CO-B4

    2  Pages

  15. CO-A4

    2  Pages

  16. COH-A2

    4  Pages

  17. Dual Sensor

    4  Pages

  18. CO-AX

    2  Pages

  19. SOH-A2

    4  Pages

  20. VOC Sensor

    2  Pages

  21. CO-AE

    2  Pages

  22. CO-AF

    2  Pages

  23. CO-BF

    2  Pages

  24. CO-BX

    2  Pages

  25. CO-CE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.