The H2S-B4 Hydrogen Sulfide Sensor is a 4-electrode sensor with dimensions specified in millimeters (± 0.15 mm). It operates within a temperature range of -30 to 50°C, a pressure range of 80 to 120 kPa, and a humidity range of 15 to 90% RH. The sensor has a storage period of 6 months when stored at 3 to 20°C in a sealed pot. It is recommended to use a load resistor of 33 to 100 Ω, and the sensor weighs less than 13 grams.
Performance:
The sensor's sensitivity is between 1450 to 2600 nA/ppm at 2ppm H2S, with a response time (t90) of less than 60 seconds from zero to 2ppm H2S. The zero current in zero air at 20°C ranges from -250 to 200 nA, and the noise level is ±2 standard deviations (ppb equivalent) at 1 ppb. The sensor's range is up to 100 ppm H2S, with a linearity error of less than ±4 ppb at full scale. The overgas limit is 200 ppm for a stable response to gas pulses.
Environmental and Lifetime:
The sensor's sensitivity at -20°C is 77 to 90% of the output at 20°C, and at 50°C, it is 100 to 110%. Zero drift is less than ±100 ppb equivalent change per year in lab air, and sensitivity drift is less than 20% change per year. The operating life is more than 24 months until 50% of the original signal, with a 24-month warranty.
Cross Sensitivity:
The sensor exhibits cross-sensitivity to various gases: NO2 (< -10%), Cl2 (< -12%), NO (< 12%), SO2 (< 20%), CO (< 3%), H2 (< 0.5%), C2H4 (< 0.1%), NH3 (< 0.1%), and CO2 (< 0.1%) at specified concentrations.
Figures and Graphs:
Figures included in the document illustrate the temperature dependence of sensitivity, zero temperature dependence, and linearity to 200 ppb H2S. The use of the Alphasense ISB circuit is recommended to reduce noise to 1 ppb, with digital smoothing options available.
Additional Notes:
All sensors are tested under ambient environmental conditions with a 47-ohm load resistor unless otherwise stated. Customers are advised to test sensors under their own conditions to ensure suitability. Disposal instructions are provided for the end of the product's life.
See more

Catalog excerpts

H2S-B4-1

Technical specifications Version 1.0 H2S-B4 Hydrogen Sulfide Sensor – 4-Electrode Bottom View Bottom View Side View Side View PERFORMANCE Performance Sensitivity Sensitivity Response time Response Zero current time Zero current Noise* Noise Range Range Linearity Linearity Overgas Overgas limit limit * nA/ppm at 2ppm H2S 1450 to 2600 nA/ppm at 2ppm H S 1450 to 2600 < 60 t90 (s) from zero to 2ppm H2S t90 (s) from zero to 2ppm H S < 60 nA in zero air at 20°C -250 to 200 nA in zero air at 20°C -250 to 200 ±2 standard deviations (ppbequivalent) equivalent) 1 ±2 standard deviations (ppb 1 100 ppm H2S limit limitperformance warranty ppm H S of of performance warranty 100 ppb error at full scale, linearatat zero 40ppm40ppm 24 Operating months until 50% original monthly test Operating life months until 50% original signal (24 month warranted) 77 to 90 Sensitivity @ 50°C % (output @ 50°C/output @ @ 20°C) @ ENVIRONMENTAL Sensitivity @ -20°C (% output @ -20°C/output 20°C) @ 2ppm H S2ppm H100 to 110 S 77 to 90 2 Zero @ -20°C nA change from 20°C 50 to 60 Sensitivity @ 50°C (% output @ 50°C/output @ 20°C) @ 2ppm H2S 100 to 110 Zero @ 50°C nA change from 20°C -120 to -160 Zero @ -20°C nA change from 20°C 50 to 60 Zero @ NO sensitivity nA change from gas @ 5ppm 50°C 20°C -120 to -160 % measured NO < -10 2 Cross Sensitivity Cl2 sensitivity % measured gas @ 5ppm Cl2 sensitivity % measured gas @ 5ppm NO2 NO NO sensitivity % measured gas @ 5ppm SO2 sensitivity % measured gas @ 5ppm sensitivity % measured gas @ 5ppm Cl2 SO2 CO sensitivity measured gas @ 5ppm % measured gas @ 5ppm CO sensitivity % NO H2 sensitivity % measured gas @ 100ppm H2 sensitivity % measured gas @ 5ppm SO2 C2H4 sensitivity % measured gas @ 100ppm C2H sensitivity % measured gas @ 5ppm CO NH 4 NH3 sensitivity % measured gas @ 20ppm 3 sensitivity % measured gas @ 100ppm H2 CO2 CO2 sensitivity % measured gas @ 5% NO2 Cl2 NO SO2 CO H2 C2H4 sensitivity % measured gas @ 100ppm C2H4 Temperature range °C Key Specifications NH3 sensitivity % measured gas @ 20ppm NH3 Pressure range kPa CO2 sensitivity % measured gas @ 5% CO2 CROSS SENSITIVITY Humidity range Storage period Temperature range°C Load resistor Pressure range kPa Weight Humidity range Storage period Load resistor Weight % rh continuous months @ 3 to 20°C (stored in sealed pot) � (ISB circuit is recommended) g % rh months @ 3 to 20°C (stored in sealed pot) Ω (ISB circuit is recommended) g For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. or visit our website at “www.alphasense.com”. At the end of the productʼs life, do not dispose of any electronic sensor, component or instrument in the domestic waste, but contact the instrument manufacturer, Alphasense or i

 Open the catalog to page 1
H2S-B4-2

Technical specifications Version 1.0 Perf erformance Data H2S-B4 Performance Data Figure 1 Sensitivity Temperature Dependence Perf erformance Data H2S-B4 Performance Data Figure 2 Sensitivity Temperature Dependence Figure 2 shows the temperature dependence of sensitivity at 2ppm H2S. % Output (referenced (referenced to 20oC) % % Output (referenced to 20oC) Outputto 20oC) Figure 2 Sensitivity Temperature Dependence H2S-B4 Performance Data Perf erformance Data 100 110 This data is taken from a typical Figure 2 shows the temperature Figure 1 shows batch of sensors. the temperature dependence of...

 Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2  Pages

  2. NO2-B43F

    2  Pages

  3. NO-B4

    2  Pages

  4. CO-B4

    2  Pages

  5. PID-AR5

    2  Pages

  6. PID-A15

    2  Pages

  7. PID-AY5

    2  Pages

  8. PID-AH5

    2  Pages

  9. SO2-D4

    2  Pages

  10. PID-AH2

    2  Pages

  11. CH-D3

    2  Pages

  12. O2-G2

    2  Pages

  13. NO2-D4

    2  Pages

  14. NO-D4

    2  Pages

  15. IRM-AT

    2  Pages

  16. H2S-D4

    2  Pages

  17. PH3-BE

    2  Pages

  18. OPC-R2

    2  Pages

  19. CL2-D4

    2  Pages

  20. CO-D4X

    2  Pages

  21. SOH-A2

    4  Pages

Archived catalogs

  1. CO2-D1

    2  Pages

  2. SO2-B4

    2  Pages

  3. SO2-A4

    2  Pages

  4. PID-AH

    2  Pages

  5. PID-A1

    2  Pages

  6. O3-B4

    2  Pages

  7. O3-A4

    2  Pages

  8. NO2-B4

    2  Pages

  9. NO2-A4

    2  Pages

  10. NO-B4

    2  Pages

  11. NO-A4

    2  Pages

  12. H2S-B4

    2  Pages

  13. H2S-A4

    2  Pages

  14. CO-B4

    2  Pages

  15. CO-A4

    2  Pages

  16. COH-A2

    4  Pages

  17. Dual Sensor

    4  Pages

  18. CO-AX

    2  Pages

  19. SOH-A2

    4  Pages

  20. VOC Sensor

    2  Pages

  21. CO-AE

    2  Pages

  22. CO-AF

    2  Pages

  23. CO-BF

    2  Pages

  24. CO-BX

    2  Pages

  25. CO-CE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.