H2S-A4

H2S-A4

H2S-A4

Product catalog summary
Performance Specifications
  • Sensitivity: 1200 to 1650 nA/ppm at 2ppm H2S.
  • Response Time: t90 < 45 seconds from zero to 2ppm H2S.
  • Zero Current: -170 to 0 nA in zero air at 20°C.
  • Noise: ±2 standard deviations equivalent to 5 ppb.
  • Range: Performance warranty limit at 50 ppm H2S.
  • Linearity: Error < ±0.5 ppb at full scale, linear at zero and 10ppm H2S.
  • Overgas Limit: Stable response up to 100 ppm gas pulse.
Lifetime Specifications
  • Zero Drift: < ±100 ppb equivalent change/year in lab air.
  • Sensitivity Drift: < 20% change/year in lab air, tested monthly.
  • Operating Life: 24 months until 50% of original signal (12-month warranty).
Environmental Specifications
  • Sensitivity at -20°C: 80 to 92% output compared to 20°C at 2ppm H2S.
  • Sensitivity at 50°C: 100 to 110% output compared to 20°C at 2ppm H2S.
  • Zero at -20°C: 30 to 50 nA change from 20°C.
  • Zero at 50°C: 90 to 110 nA change from 20°C.
Cross Sensitivity
  • NO2: < -20% measured gas at 5ppm NO2.
  • Cl2: < -8% measured gas at 5ppm Cl2.
  • NO: < 3% measured gas at 5ppm NO.
  • SO2: < 15% measured gas at 5ppm SO2.
  • CO: < 1% measured gas at 5ppm CO.
  • H2: < 0.5% measured gas at 100ppm H2.
  • C2H4: < 0.5% measured gas at 100ppm C2H4.
  • NH3: < 0.1% measured gas at 5ppm NH3.
  • CO2: < 0.1% measured gas at 5% CO2.
Key Specifications
  • Temperature Range: -30 to 50°C.
  • Pressure Range: 80 to 120 kPa.
  • Humidity Range: 15 to 90% relative humidity.
  • Storage Period: 6 months at 3 to 20°C in a sealed pot.
  • Load Resistor: 33 to 100 Ω (AFE circuit recommended).
  • Weight: < 6 grams.
Additional Notes
  • All sensors are tested under ambient conditions with a 47 ohm load resistor unless otherwise stated.
  • Customers should test sensors under their own conditions to ensure suitability.
  • Contact Alphasense for disposal instructions at the end of the product's life.
Figures and Diagrams
  • Figure 1: H2S-A4 Schematic Diagram.
  • Figure 2: Sensitivity Temperature Dependence.
  • Figure 3: Zero Temperature Dependence (uncorrected).
  • Figure 4: 0 to 200ppb Linearity.
See more

Catalog excerpts

H2S-A4-1

H2S-A4 Hydrogen Sulfide Sensor iffDROSEH SULFJ Figure 1 H2S-A4 Schematic Diagram ^Hydrogen Sulfide Bottom View Side View Response time Zero current Overgas limit ±2 standard deviations (ppb equivalent) ppm H2S limit of performance warranty ppb error at full scale, linear at zero and 10ppm H2S maximum ppm for stable response to gas pulse Tested with Alphasense AFE low noise circuit LIFETIME Zero drift ppb equivalent change/year in lab air <±100 Sensitivity drift % change/year in lab air, monthly test < 20 Operating life months until 50% original signal (12 month warranted) 24 Pressure range Humidity range Storage period Load resistor months @ 3 to 20°C (stored in sealed pot) At the end of the product's life, do not dispose of any electronic sensor, component or instrument in the domestic waste, but contact the instrument manufacturer, Alphasense or its distributor for disposal instructions. NOTE: all sensors are tested at ambient environmental conditions, with 47 ohm load resistor, unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley. CM77 7AA. UK

 Open the catalog to page 1
H2S-A4-2

H2S-A4 Performance Data Perf erformance Data Figure 2 Sensitivity Temperature Dependence Figure 2 shows the temperature dependence of sensitivity at 2ppm H2S. This data is taken from a typical batch of sensors. Figure 3 Zero Temperature Dependence (uncorrected) 100 Figure 3 shows the variation in zero output of the working electrode caused by changes in temperature, expressed as nA. This data is taken from a typical batch of sensors. Contact Alphasense for futher information on zero current correction. Figure 4 shows response to 200ppb H2S. Use of Alphasense AFE circuit reduces noise to 5ppb,...

 Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2  Pages

  2. NO2-B43F

    2  Pages

  3. NO-B4

    2  Pages

  4. H2S-B4

    2  Pages

  5. CO-B4

    2  Pages

  6. PID-AR5

    2  Pages

  7. PID-A15

    2  Pages

  8. PID-AY5

    2  Pages

  9. PID-AH5

    2  Pages

  10. SO2-D4

    2  Pages

  11. PID-AH2

    2  Pages

  12. CH-D3

    2  Pages

  13. O2-G2

    2  Pages

  14. NO2-D4

    2  Pages

  15. NO-D4

    2  Pages

  16. IRM-AT

    2  Pages

  17. H2S-D4

    2  Pages

  18. PH3-BE

    2  Pages

  19. OPC-R2

    2  Pages

  20. CL2-D4

    2  Pages

  21. CO-D4X

    2  Pages

  22. SOH-A2

    4  Pages

Archived catalogs

  1. CO2-D1

    2  Pages

  2. SO2-B4

    2  Pages

  3. SO2-A4

    2  Pages

  4. PID-AH

    2  Pages

  5. PID-A1

    2  Pages

  6. O3-B4

    2  Pages

  7. O3-A4

    2  Pages

  8. NO2-B4

    2  Pages

  9. NO2-A4

    2  Pages

  10. NO-B4

    2  Pages

  11. NO-A4

    2  Pages

  12. H2S-B4

    2  Pages

  13. CO-B4

    2  Pages

  14. CO-A4

    2  Pages

  15. COH-A2

    4  Pages

  16. Dual Sensor

    4  Pages

  17. CO-AX

    2  Pages

  18. SOH-A2

    4  Pages

  19. VOC Sensor

    2  Pages

  20. CO-AE

    2  Pages

  21. CO-AF

    2  Pages

  22. CO-BF

    2  Pages

  23. CO-BX

    2  Pages

  24. CO-CE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.