CO-D4 Carbon Monoxide Sensors
2Pages

{{requestButtons}}

Catalog excerpts

CO-D4 Carbon Monoxide Sensors - 1

Figure 1 CO-D4 Schematic Diagram > PATENTED and PATENTPENDING All dimensions in millimetres ( 0.1 mm) Top ViewBottom ViewSide View (A three pin version is available on request, coded CO-DF) PERFORMANCE SensitivitynA/ppm in 400ppm CO30 to 48Response timet > 90 (s) from zero to 400ppm CO % 22ѰC< 25Zero currentppm equivalent in zero air< 3ResolutionRMS noise (ppm equivalent)< 1.5Rangeppm limit of performance warranty1,000Linearityppm CO error at full scale, linear at zero and 400ppm CO ѱ 40Overgas rangemaximum ppm for stable response to gas pulse2,000 LIFETIME Zero driftppm equivalent change/year in lab air< 0.2Sensitivity drift% change/month in lab air, monthly test<0.5Operating lifemonths until 80% original signal (24 month warranted)> 24 > ENVIRONMENTAL Sensitivity @ -20C% (output @ -20аC/output @ 20C) @ 400ppm CO72 to 84Sensitivity @ 50аC% (output @ 50C/output @ 20аC) @ 400ppm CO105 to 111 Zero @ -20Cppm equivalent change from20аC< 3 Zero @ 50ѰCppm equivalent change from 20C< б 4 CROSS Filter capacityppmhrsH > 2 S20,000 SENSITIVITY SO > 2 sensitivity% measured gas @ 20ppmSO > 2 < 0.1NOsensitivity% measured gas @ 50ppmNO< 50NO > 2 sensitivity% measured gas @ 10ppmNO > 2 < 0.1Cl > 2 sensitivity% measured gas @ 10ppmCl > 2 < 0.1H > 2 sensitivity% measured gas @ 400ppmH > 2 < 70C > 2 H > 4 sensitivity% measured gas @ 400ppmC > 2 H > 4 < 100H > 2 Ssensitivity% measured gas @ 20ppmH > 2 S< 0.1NH > 3 sensitivity% measured gas @ 20ppmNH > 3 < 0.1 KEY Temperature range > O C-20 to 50 SPECIFICATIONS Pressure rangekPa80 to 120Humidity range%rh (see note below)15 to 90Storage periodmonths @ 3 to 20 > O C (stored in sealed pot)6Load resistor עĦ (recommended)10 to 100Weightg< 2 > Note: Above 85% rh and 40 O C a maximum continuous exposure period of 10 days is warranted. Where such exposure occurs thesensor will recover normal electrolyte volumes when allowed to rest at lower %rh and temperature levels for several days. NOTE: all sensors are tested at ambient environmental conditions, with 10 ohm load resistor, unless otherwise stated. As applications of use are outside our control,the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their ownrequirements. TT TTTecec ececechnical Specifhnical Specifhnical Specifhnical Specifhnical Specificaica icaicaicationtion tiontiontion Alphasense Ltd, Sensor Technology House, 300 Avenue West, Skyline 120, Great Notley. CM77 7AA. UKTelephone: +44 (0) 1376 556 700 Fax: +44 (0) 1376 335 899 E-mail: sensors@alphasense.com Website: www.alphasense.com size="-3">

Open the catalog to page 1

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2 Pages

  2. NO2-B43F

    2 Pages

  3. NO-B4

    2 Pages

  4. H2S-B4

    2 Pages

  5. CO-B4

    2 Pages

  6. PID-AR5

    2 Pages

  7. PID-A15

    2 Pages

  8. PID-AY5

    2 Pages

  9. PID-AH5

    2 Pages

  10. SO2-D4

    2 Pages

  11. PID-AH2

    2 Pages

  12. CH-D3

    2 Pages

  13. O2-G2

    2 Pages

  14. NO2-D4

    2 Pages

  15. NO-D4

    2 Pages

  16. IRM-AT

    2 Pages

  17. H2S-D4

    2 Pages

  18. PH3-BE

    2 Pages

  19. OPC-R2

    2 Pages

  20. CL2-D4

    2 Pages

  21. CO-D4X

    2 Pages

  22. SOH-A2

    4 Pages

Archived catalogs

  1. CO-CE

    2 Pages

  2. CO-BX

    2 Pages

  3. CO-BF

    2 Pages

  4. CO-AF

    2 Pages

  5. CO-AE

    2 Pages

  6. VOC Sensor

    2 Pages

  7. SOH-A2

    4 Pages

  8. CO-AX

    2 Pages

  9. Dual Sensor

    4 Pages

  10. COH-A2

    4 Pages

  11. CO-A4

    2 Pages

  12. CO-B4

    2 Pages

  13. H2S-A4

    2 Pages

  14. H2S-B4

    2 Pages

  15. NO-A4

    2 Pages

  16. NO-B4

    2 Pages

  17. NO2-A4

    2 Pages

  18. NO2-B4

    2 Pages

  19. O3-A4

    2 Pages

  20. O3-B4

    2 Pages

  21. PID-A1

    2 Pages

  22. PID-AH

    2 Pages

  23. SO2-A4

    2 Pages

  24. SO2-B4

    2 Pages

  25. CO2-D1

    2 Pages