Catalog excerpts
Technical specifications Version 2.0 PID-AR5 Photo Ionisation Detector Bottom View Side View Dimensions are in millimetres (+/- 0.1 mm). Use of socketed connection is required. Soldering or cutting the connection pins may permanently damage the sensor and void the warranty. Target gases Minimum Detection Level (ppb) Linear Range (ppm) Overrange (ppm) Sensitivity minimum range* Sensitivity typical range* Full stabilisation time Warm up time Offset Voltage (mV) Response Time (t90 sec) VOCs with ionisation potentials < 10.6 eV 10 200 200 6 mV/ppm 11 mV/ppm 5 minutes 5 seconds 40-75 2 Power Consumption Supply Voltage Output Signal 80 mW - 200 mW depending on supply voltage 3.2 to 5.5 VDC 0.040 to 2.85 V Temperature Range Temperature Dependence Relative Humidity Range Humidity Sensitivity -20oC to 60oC see chart 0 to 95% non-condensing Near zero (to 75%RH) Operating Life IS Approval 5 years (excluding replaceable lamp and electrode stack) (No additional circuitry or external fusing required for intrinsic safety) Onboard Filter Lamp Electrode Stack Weight Position Sensitivity Warranty Period Patent information T: +44 (0)1376 556700 To remove liquids and particulates User Replaceable. Expected life = 10,000 hours User Replaceable <8 grams None Electronics and Housing 24 Months, Lamp 12 months. Electrode and lamp are user replaceable. 10.6 eV lamp typical life 10,000 hours. US Pat 6,646,444. Japan Pat 3,793,757 *Gain numbers measured with isobutylene at room temperature and sea level. For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. or visit our website at “www.alphasense.com”
Open the catalog to page 1Technical specifications Version 2.0 Figure 2 shows the response curve of 20 sensors throughout the entire operating range. Sensors are linear throughout the entire range. Fig. 3 Sensitivity Temperature Dependence Figure 3 shows the mean and ±95% confidence intervals of the response of the sensors to 30 ppm isobutylene over the entire temperature range. The temperature response follows the ideal gas law. PID-AR5 Replacement Parts/Consumables List Part Number Part Number Maintenance Kit, which includes: 2 ea Polishing Disc 2 ea 10 μm, Cloth, Bottom Filter 2 ea 1 μm, Teflon, Top Filter, Large...
Open the catalog to page 2All Alphasense catalogs and technical brochures
-
SO2-B4
2 Pages
-
NO2-B43F
2 Pages
-
NO-B4
2 Pages
-
H2S-B4
2 Pages
-
PID-AR5
2 Pages
-
PID-A15
2 Pages
-
PID-AY5
2 Pages
-
PID-AH5
2 Pages
-
SO2-D4
2 Pages
-
PID-AH2
2 Pages
-
CH-D3
2 Pages
-
O2-G2
2 Pages
-
NO2-D4
2 Pages
-
NO-D4
2 Pages
-
IRM-AT
2 Pages
-
H2S-D4
2 Pages
-
PH3-BE
2 Pages
-
OPC-R2
2 Pages
-
CL2-D4
2 Pages
-
CO-D4X
2 Pages
-
SOH-A2
4 Pages
Archived catalogs
-
CO-CE
2 Pages
-
CO-BX
2 Pages
-
CO-BF
2 Pages
-
CO-AF
2 Pages
-
CO-AE
2 Pages
-
VOC Sensor
2 Pages
-
Hydrogen Sulfide Sensor
2 Pages
-
CL2-D4 Chlorine Sensor
2 Pages
-
CL2-B1 Chlorine Sensor
2 Pages
-
CL2-A1 Chlorine Sensor
2 Pages
-
SOH-A2
4 Pages
-
CO-AX
2 Pages
-
Dual Sensor
4 Pages
-
COH-A2
4 Pages
-
Carbon Monoxide Sensor
2 Pages
-
OX-A431 Oxidising Gas Sensor
4 Pages
-
OX-B431 Oxidising Gas Sensor
4 Pages
-
CO-A4
2 Pages
-
CO-B4
2 Pages
-
H2S-A4
2 Pages
-
H2S-B4
2 Pages
-
IRC-A1 Carbon Dioxide
3 Pages
-
IRC-AT Carbon Dioxide
2 Pages
-
IRM-AT Methane
2 Pages
-
NO-A4
2 Pages
-
NO-B4
2 Pages
-
NO2-A4
2 Pages
-
NO2-B4
2 Pages
-
O3-A4
2 Pages
-
O3-B4
2 Pages
-
PID-A1
2 Pages
-
PID-AH
2 Pages
-
SO2-A4
2 Pages
-
SO2-B4
2 Pages
-
AFE Sensor Board
2 Pages
-
ISB Individual Sensor Board
2 Pages
-
NDIR Transmitter Board
1 Pages
-
CO2-D1
2 Pages
-
4-20mA Transmitter Boards
2 Pages
-
NO-B1 Nitric Oxide Sensors
2 Pages
-
NO-A1 Nitric Oxide Sensors
2 Pages
-
D2 Miniature Sensors
4 Pages
-
CH-D3 Flammable Gas Sensors
2 Pages
-
CH-A3 Flammable Gas Sensors
2 Pages
-
CL2-B1 Chlorine Sensors
2 Pages
-
CL2-A1 Chlorine Sensors
2 Pages
-
Combustible LEL Sensor
2 Pages
-
Nitrogen Dioxide sensor
2 Pages
-
NDIR CO2 Sensor
4 Pages