CL2-D4

CL2-D4

CL2-D4

Product catalog summary
Overview: The CL2-D4 Chlorine Sensor is a miniature sensor designed for detecting chlorine gas. It is manufactured by Alphasense Ltd and is characterized by its compact size and high sensitivity.
Performance Specifications:
  • Sensitivity: -150 to -350 nA/ppm in 10ppm Cl2.
  • Response Time: Less than 35 seconds to reach 90% of the final value from zero to 10ppm Cl2.
  • Zero Current: ±0.8 ppm equivalent in zero air.
  • Resolution: Less than 0.1 ppm equivalent RMS noise.
  • Range: Performance warranty up to 20 ppm Cl2.
  • Linearity: ±0.5 ppm error at full scale, linear at zero and 10ppm Cl2.
  • Overgas Limit: Stable response to gas pulse up to 60 ppm.
Lifetime and Drift:
  • Operating Life: More than 18 months until 80% of the original signal, with a 24-month warranty.
  • Zero Drift and Sensitivity Drift: Not determined (nd) in lab air.
Environmental Specifications:
  • Temperature Sensitivity: 80 to 110% at -20°C and 95 to 125% at 50°C compared to 20°C.
  • Zero Temperature Dependence: -0.4 to 0.4 ppm equivalent change at -20°C and 0 to 0.5 ppm at 50°C from 20°C.
Cross Sensitivity:
  • H2S: Less than -200% at 20ppm.
  • NO2: Less than 120% at 10ppm.
  • NO: Less than 0.5% at 50ppm.
  • SO2: Less than -3% at 20ppm.
  • CO, H2, C2H4, NH3: Less than 0.1% at respective concentrations.
Key Specifications:
  • Temperature Range: -20 to 50°C.
  • Pressure Range: 80 to 120 kPa.
  • Humidity Range: 15 to 90% relative humidity.
  • Storage Period: 6 months at 3 to 20°C in a sealed pot.
  • Load Resistor: 33 Ω for optimum performance.
  • Weight: Less than 2 grams.
Figures and Data:
  • Figure 1: Response to 10ppm Cl2 shows typical sensor batch data.
  • Figure 2: Zero Temperature Dependence illustrates variation in zero output with temperature changes.
  • Figure 3: Load Resistor Dependence indicates that higher resistance reduces noise but increases response time.
Additional Notes: Sensors are tested under ambient conditions unless otherwise stated. Users should verify suitability under their own conditions. Disposal instructions are provided by the manufacturer or distributor.
See more

Catalog excerpts

CL2-D4-1

CL2-D4 Chlorine Sensor Miniature Size Technical specifications Version 1.0 Figure 1 CL2-D4 Schematic Diagram CL2-D4 Chlorine Sensor – Miniature Size Bottom View Bottom View Side View View Side Sensitivity Response time Sensitivity Zero Response time current Resolution Zero current Resolution Range Range Linearity Linearity Overgas limit nA/ppm in 10ppm Cl2 -150 to -350 < 35 t90 (s) from zero to 10ppm Cl2 nA/ppm in 10ppm Cl -150 to -350 ppm equivalent in zero air ± 0.8 t90 (s) from zero to 10ppm Cl < 35 RMS noise (ppm equivalent) < 0.1 ppm equivalent in zero air ± 0.8 RMS noise (ppm equivalent) < 0.1 ppm Cl2 limit of performance warranty 20 ppm Cl limit of performance linear at zero and 10ppm Cl warranty 20 ± 0.5 ppm error at full scale, 2 ppm error ± 0.5 maximum at full scale, stable zero and 10ppm Clgas pulse ppm for linear at response to 60 Zero drift Zero drift Sensitivity drift Sensitivity drift Operating life ppm equivalent change/year in lab air ppm equivalent change/year air, air nd % change/month in lab in labtwice monthly test % change/month in lab air, twice monthly test monthnd months until 80% original signal (24 warranted) Overgas limit LIFETIME Lifetime Operating life ENVIRONMENTAL Sensitivity @ -20°C Sensitivity @ 50°C Sensitivity @ -20°C Environmental Zero Sensitivity @ 50°C @ -20°C Zero50°C Zero @ @ -20°C Zero @ 50° CROSS SENSITIVITY Cross Sensitivity maximum ppm for stable response to gas pulse months until 80% original signal (24-month warranted) ppm equivalent change from 20°C KEY Temperature range Temperature range Key Specifications SPECIFICATIONSPressure range Pressure range Humidity range Humidity range Storage period Storage period Load Load resistor resistor Weight Weight H2S sensitivity % measured gas @ 20ppm NO2 H S sensitivity % measured gasgas @ 10ppm sensitivity % measured @ 20ppm NO sensitivity % measured gas @ 50ppm % measured gas @ 10ppm NO sensitivity NO sensitivity % measured gas @ 20ppm % measured gas @ 50ppm SO2 sensitivity SO sensitivity % measured gas @ 20ppm CO CO sensitivity % measured gasgas @ 400ppm sensitivity @ 400ppm % measured H2 H sensitivity % measured gasgas @ 400ppm sensitivity % measured @ 400ppm C2H4Csensitivity % measured gas @ 400ppm H sensitivity % measured gas @ 400ppm % measured @ 20ppm NH3 NH sensitivity % measured gasgas @ 20ppm sensitivity 2 kPa kPa 80 to 120 %rh rh (see note below) % (see note below) 15 to 90 months @ to to 20OC (stored in months @3 3 20°C (stored in sealed pot) sealed pot)6 � (for optimum performance) 33 Ω (for optimum performance) g <2 g Note: Above 85% rh and 40oC a maximum continuous exposure period of 10 days is warranted. Where such exposure occurs the sensor will recover normal electrolyte volumes when allowed to rest at lower % rh and temperature levels for several days. T: +44 (0)1376 556700 For further information on the performance of this sensor, on other sensors in the range or any other subject, please contact Alphasense Ltd. or visit our website at “www.alphasense.com”. At the end of the productʼs life, do not dispose of any electronic sensor, component or instrument in the domestic waste, but contact the instrument manufacturer, Alphasense or its dis

 Open the catalog to page 1
CL2-D4-2

Technical specifications Version 1.0 Perf erformance Data CL2-D4 Performance Data Perf erformance Data CL2-D4 Performance Data Figure 2 shows response to 10ppm Cl2. Perf erformance Data CL2-D4 Performance Data -1000 500 (nA) Zero Noise RMS (nA) Zero Noise RMSZero Noise RMS (nA) referenced to referenced to 20referenced to 20oC (equivalent ppm) Zero output, Zero output, 20oZero output, oC (equivalent ppm) C (equivalent ppm) Output (nA) Output (nA) Technical Specification tion Technical Specification Technical Specifica This data is taken from a typical batch of sensors. Figure 2 shows response...

 Open the catalog to page 2

All Alphasense catalogs and technical brochures

  1. SO2-B4

    2  Pages

  2. NO2-B43F

    2  Pages

  3. NO-B4

    2  Pages

  4. H2S-B4

    2  Pages

  5. CO-B4

    2  Pages

  6. PID-AR5

    2  Pages

  7. PID-A15

    2  Pages

  8. PID-AY5

    2  Pages

  9. PID-AH5

    2  Pages

  10. SO2-D4

    2  Pages

  11. PID-AH2

    2  Pages

  12. CH-D3

    2  Pages

  13. O2-G2

    2  Pages

  14. NO2-D4

    2  Pages

  15. NO-D4

    2  Pages

  16. IRM-AT

    2  Pages

  17. H2S-D4

    2  Pages

  18. PH3-BE

    2  Pages

  19. OPC-R2

    2  Pages

  20. CO-D4X

    2  Pages

  21. SOH-A2

    4  Pages

Archived catalogs

  1. CO2-D1

    2  Pages

  2. SO2-B4

    2  Pages

  3. SO2-A4

    2  Pages

  4. PID-AH

    2  Pages

  5. PID-A1

    2  Pages

  6. O3-B4

    2  Pages

  7. O3-A4

    2  Pages

  8. NO2-B4

    2  Pages

  9. NO2-A4

    2  Pages

  10. NO-B4

    2  Pages

  11. NO-A4

    2  Pages

  12. H2S-B4

    2  Pages

  13. H2S-A4

    2  Pages

  14. CO-B4

    2  Pages

  15. CO-A4

    2  Pages

  16. COH-A2

    4  Pages

  17. Dual Sensor

    4  Pages

  18. CO-AX

    2  Pages

  19. SOH-A2

    4  Pages

  20. VOC Sensor

    2  Pages

  21. CO-AE

    2  Pages

  22. CO-AF

    2  Pages

  23. CO-BF

    2  Pages

  24. CO-BX

    2  Pages

  25. CO-CE

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.