Natural Gas Dew-point Sampling Systems - TEG

Natural Gas Dew-point Sampling Systems - TEG

Natural Gas Dew-point Sampling Systems - TEG

Product catalog summary
Overview: The document describes the SS-TEG and SS-NGH Dewpoint Sample Systems designed for natural gas applications, particularly where TEG or heavy hydrocarbon condensate may be present. These systems are used to present a sample of natural gas to a moisture analyzer's dewpoint transmitter.
Specifications:
  • Incorporates ATEX certified heated pressure regulators.
  • Inlet pressure capability up to 210 barg.
  • Sensor operates at inlet or atmospheric pressure.
  • Weatherproofing with an IP66 rating.
  • Constructed with 316 stainless steel for sensor holders, pipework, and fittings.
  • Dimensions: Approximately 1000 x 840 x 300 mm; Weight: Approx 75 kg.
Features and Benefits:
  • Manual selector valves for process and auxiliary inlets.
  • Sample inlet and outlet pressure indication.
  • Electrically heated pressure regulators for sample control.
  • Professionally built, easy to install, rugged, and compact design.
Technical Data:
  • Pressure regulator maximum: 210 bar (3,045 PSI).
  • Recommended hygrometers: DS4000-AMT-Ex and DS1200-AMT-Ex, both featuring a 4-20mA transmitter and automatic calibration (AutoCal).
System Configuration:
  • SS-TEG model: Pressure reduced upstream for atmospheric pressure dewpoint or moisture concentration measurement.
  • SS-NGH-P model: Pressure reduced downstream for disposal after measuring dewpoint at sample pressure.
Ordering and Customization: The systems can be customized to meet specific requirements, with options for standard or made-to-measure configurations. Heated regulators can be installed for 115 VAC or 230 VAC operation.
Contact Information: For further inquiries or to discuss specific requirements, contact Alpha Moisture Systems Ltd. via phone or email.
See more

Catalog excerpts

Natural Gas Dew-point Sampling Systems - TEG-1

TEG Natural Gas Dewpoint Sample System Incorporates ATEX certified heated pressure regulators Process and auxiliary inlet with manual selector valves Sensor operates at inlet or atmospheric pressure Electrically heated pressure regulators for control of sample Inlet pressure up to 210 barg Sample inlet and outlet pressure indication Professionally built - Easy to install - Rugged - Compact Design Manufactured to exact specifications The SS-TEG is a sample system designed to present a sample of Natural Gas to the Dewpoint Transmitter of a moisture analyser when TEG or heavy hydrocarbon condensate may be present, typically downstream of a glycol contactor. The system includes particle filtering, pressure control and flow control to condition the sample for presentation to the moisture sensor, which is incorporated into the system. It can either be configured so that the pressure is reduced upstream of the sensor for measuring atmospheric pressure dewpoint or moisture concentration (SS-TEG model), or so that the pressure is reduced downstream of the sensor for disposal after measuring the dewpoint at sample pressure (SS-NGH-P model). Standard Recommended Dewpoint Hygrometers for use with SS-TEG Sample System DS1200-AMT-Ex intrinsically safe standard dewpoint hygrometer can be used with the SS-TEG sample systems. This hygrometer incorporates a 4-20mA transmitter with various ranges available between -110 °C to +20 °C Td. The AMT-Ex has an Automatic Calibration (AutoCal) function as standard. DS4000-AMT-Ex is our latest addition to the Hygrometer family, again perfect for hazardous continuous measurement applications. The AMT-Ex Transmitter is a three wire 4-20mA transmitter with Automatic Calibration (AutoCal) The DS4000 has many more advanced functions and features compared with the standard DS1200 display. SS-TEG - Dewpoint Sampling System Technical Data Weather Proofing Pressure Regulator Sensor Holder Pressure Gauges Pipework Fittings Dimensions (HxWxD) Weight IP66 rating 210 bar (3,045 PSI) Maximum 316 Stainless Steel Inlet, Sample and Bypass as standard All Stainless Steel All Stainless Steel Approx 1000 x 840 x 300 mm Approx 75 kg (165

 Open the catalog to page 1
Natural Gas Dew-point Sampling Systems - TEG-2

Dimensions Model SS-TEG Drawing Schematic Example Side Elevation Front Elevation The heated regulators incorporated in the system can be installed for 115 VAC or 230 VAC operation, as specied on order. DS4000 Hygrometer Display Technical Specications - See Datasheet - Document No. 3037 DS1200 Hygrometer Display Technical Specications - See Datasheet - Document No. 3039 Standard or Made to Measure Natural Gas TEG Dewpoint Sample Systems Please Contact us to discuss your exact requirements with our experienced Technical Sales Engineers. Dewpoint measurement requirements within the Natural Gas Sector...

 Open the catalog to page 2