Group: HALMA
Catalog excerpts
DS1500 Dewpoint Hygrometer Display Panel mounted. NEW RS485 / MODBUS (RTU) serial communication enabled 4 alarm relays – 2 x change over, 2 x normally open (NO) Compatible with AMT, PDT and AMT-Ex dewpoint transmitters Installed in the safe area unless housed in an Exd Enclosure Panel mounted single channel indicator Process Variable (PV) retransmission in 0-20 mA or 4-20 mA The DS1500 is a digital dewpoint hygrometer display and fully compatible with the Alpha Moisture Systems’ AMT, PDT and AMT-Ex Dewpoint Transmitters for continuous trace moisture measurement in most gases and dry compressed air. The DS1500 system is factory configured to user specification to read in either °C dewpoint, °F dewpoint, ppm(v), ppb(v), g/m³ or lbs/MMSCF. The measured value is displayed on a large six-digit red LED display. DS1500 offers a selectable 0-20 mA or 4-20 mA isolated retransmission signal and four programmable alarm relays. Option For Non-Hazardous Areas Option For Ex Hazardous Areas - See AMT-Ex Datasheet for details. Instrument configuration is achieved from the front keypad, without any hardware change. The selection of input type and alarm modes and other special functions, are also accessed and defined from the front keypad. A digital communication channel is provided via a RS485 (MODBUS RTU Communication Protocol) serial connection for remote interrogation of measured values and status of alarms and instrument. DISPLAY - DS1500 Type: Annunciators: Power: RELAY OuTPuT 1 AND 2 Contact Type: Rating: RELAY OuTPuT 3 AND 4 Contact Type: Rating: LINEAR (RE-TRANSMITTED) OuTPuT Ranges Available: Accuracy: Load Impedance: Red 7-segment 6-digit primary display Alarms 1 to 4 status LEDS. 100 to 240 Vac/dc +/-10 %, 50/60 Hz Single pole, changeover (SPDT) 3 A resistive, 240 Vac, 50/60Hz (3 A / 30 Vdc Res.) Single pole, changeover (SPST-NO:) 1.5 A resistive, 250 Vac, 50/60Hz (3 A / 30 Vdc Res.) 0-20mA or 4-20mA linear in units selected ±0.5% max of displa
Open the catalog to page 1Specifications Continued SERIAL COMMUNICATIONS Protocol: MODBUS (RTU) Data Format: Number of databits: 8, without parity, and one stop bit. Baud Rate: Selectable - 1200, 2400, 4800, *9600, 19200, 38400 or 57600 bps. *Factory Default Safety: Complies with BS EN 61010-1 Instrument Front Panel Seal: To IP54 PHYSICAL (CONTROL uNIT) Operating Conditions Temperature: 5 °C to 50 °C Relative Humidity: 0-90% non-condensing Warranty 12 months in case of defective parts or faulty workmanship Dimensions and Electrical Connections 100-240 POWER ALARM 2 ALARM 1 Vac/dc ALARM 4 ALARM 3 no TRANSMITTER...
Open the catalog to page 2Download PDF's from our website: amsystems.co.uk Order: DS1500 (Display Only) AMT-Ex For Hazardous Applications AMT Used with DS1500 in the safe area PDT Used with DS1500 in the safe area Isolator Used with AMT-Ex. Isolator and DS1500 in the safe area Corrosive Gases: The Sensor should not be exposed to corrosive gases (or corrosive contaminants in the gas sample) as these can chemically attack the sensor, impairing calibration accuracy and/or damaging it beyond economic repair. Examples of such gases are mercury (Hg), ammonia (NH3), chlorine (C^) etc. Strong oxidising agents such as ozone...
Open the catalog to page 3All Alpha Moisture Systems Ltd catalogs and technical brochures
-
Model 6020 User Manual
41 Pages
-
SADPmini2 User Manual
57 Pages
-
AMT User Manual
14 Pages
-
AMT-Ex User Manual
15 Pages
-
PSS User Manual
17 Pages
-
SADPmini2-Ex User Manual
86 Pages
-
DS1200-Exd-AMT-Ex
3 Pages
-
DS1500-Exd
2 Pages
-
DS4000-Exd-AMT-Ex
3 Pages
-
DSP-FCI Portable Hygrometer
3 Pages
-
Model 6020 Exd
4 Pages
-
Model 6020
3 Pages
-
SADPmini2 Comparison Chart
1 Pages