167 Low Differential Pressure Transducer - 1

Low Differential Pressure Transducer alpha" instruments The Model 167 Series are low range differential pressure transducers and transmitters. It was specially designed for 35mm DIN Rail Mount, which dramatically reduces the required mounting space and installation cost. The green and red LED indicators show the working status of the unit in the field. The Model 167 Series are available for full scale pressure range from 0 to 0.1"WC till 0 to 100"WC. Both unidirectional and bidirectional pressure ranges are offered. The output of the Model 167 Pressure Transducer is available in two versions: 0 to 5VDC and 0 to 10VDC, where 0VDC is true zero without offset. The output of Model 167 Pressure Transmitter is 4 to 20 mA. The Units can be temperature compensated to 0.01%FS/°F. The accuracy can be 0.6%, 0.4% or 0.25% at room temperature. The patented variable capacitance pressure sensor is constructed by stainless steel and glass, no glue or other organics. That provides excellent performance, corrosion resistance and long-term stability. Additionally, our unique production setup allows us to accommodate special orders for nonstandard pressure ranges (e.g. -0.5"WC to +3.5"WC). Model 167 Specifications Performance Data Accuracy* (at room temp) Non-Linearity (BFSL) Hysteresis Non-Repeatability Thermal Effects: Zero/Span Shift (/°F) Compensated Range Maximum Line Pressure Overpressure Stability Warm-up Shift 20 to 170° F(-7 to 77°C) 15PSI(100kPa) 15PSI(100kPa) in Positive or Negative Direction for all Ranges ±0.5% FS/YR ±0.1%FS Position Effect Each unit is calibrated in the vertical position. For best accuracy, adjust zero of the unit if it is mounted in other position. It is not necessary to adjust the sensitivity. * RSS of Non-Linearity, Hysteresis, and Non-Repeatability. Environmental Data and Physical Description Applications: ■ Power Plant Air Flow Monitor and Control ■ Textile Machinery ■ Clean Room and Fume Hood Control ■ Duct Static Pressure Measurement ■ Draft Control ■ HVAC and VAV Control ■ Furnace Air Flow Control Features • LED Working Status Indicators • DIN Rail Mount • Up to 15 PSI Overpressure on All Ranges • Detachable Euro Style Terminal Block Reduces Wiring Errors and Field Wiring Time. • Incorrect Wiring Protection • Unsymmetrical Bidirectional Pressure Ranges • True Zero Output for Voltage Unit • Meets C€ Conformance Standards • Meets RoHS Requirements • Pressure Ranges as Low as 10Pa! Operating Temperature Storage Temperature LED for Quick Status Diagnostics Electrical Termination Pressure Fittings Zero & Span Adjustment Pressure Media Enclosure Weight Installation Green and Red On ... Too much Pressure to Positive Side. 5mm Euro style pluggable terminal block accepts 12-24 gauge wire 3/16” O.D. barbed brass for 1/8” I.D. push-on tubing(standard). 8mm O.D. barbed brass(optional). Top accessible Typically air or similar non-conducting gases PC+ABS Alloy, Nickel Plated or 94V-0 Rated 7.0OZ/198g 35mm DIN Rail (EN50022). Visit us Online: www.alphainstruments.com E-mail: sales@alphainstruments.com

Open the catalog to page 1
167 Low Differential Pressure Transducer - 2

Model 167 Specifications Electrical Data (Voltage) Circuit Excitation Output* Output Impedance * Zero output: factory set at ±25mV(0-5VDC), ±50mV(0-10VDC) Span output: factory set at ±25mV(0-5VDC), ±50mV(0-10VDC) Calibrate with a 50K OHM load. Operable with a load greater than 5K OHM for 0-5VDC output, greater than 10K OHM for 0-10VDC output. Electrical Data (Current) Circuit Excitation Output** Bidirectional Output at Zero External Load * 3-Wire (+EXC, -EXC, OUTPUT),Protected against incorrect wiring 16-32VDC/16-30VAC 0-5VDC, 0-10VDC ≤5.0 OHMS 2-Wire(+EXC, -EXC), Protected against incorrect...

Open the catalog to page 2

All Alpha Instruments Company catalogs and technical brochures