1. Catalogs
  2. ALNOR Ventilation Systems
  3. Overview of fans & accesories - ERP 2015

Overview of fans & accesories - ERP 2015

Overview of fans & accesories - ERP 2015
1 / 11 PagesView full catalog

Overview of fans & accesories - ERP 2015

Product catalog summary
Introduction to ErP Directive:
The ErP Directive, which stands for 'Energy-related Products', aims to improve energy efficiency and reduce greenhouse gas emissions as part of the EU Climate and Energy Package. Initially introduced as the EuP directive in 2005, it was updated to the ErP directive in 2009. The directive targets a 20% increase in rotor-fan unit efficiency, a 20% reduction in greenhouse gas emissions, and a 20% increase in renewable energy usage by 2020. Regulation 327/2011 applies to fans with electric motors ranging from 0.125kW to 500kW, with exceptions for smoke extract and explosion-proof fans.
ErP 2015 Regulation:
Regulation 1254/2014 mandates energy labels for residential ventilation systems in the EU, effective January 2015. Exceptions include systems with power consumption below 30W, those used in explosive environments, and systems operating under extreme conditions. Labels must include supplier information, model identifier, energy efficiency class, sound power level, and maximum flow intensity.
Energy Classification and Labeling:
Regulation 1254/2014 details the energy classification of ventilation systems, specifying the calculation method for Specific Energy Consumption and energy class division. Labels feature energy efficiency classes from A+++ to A-20%, sound power levels, and maximum airflow rates.
Duct Fans Overview:
Duct fans, such as the DV-PP-L and DV-SQ models, are designed for various applications, including general ventilation and specific environments like bathrooms and workshops. These fans are noted for their high efficiency, low noise, and versatile installation options.
Roof Fans Overview:
Roof fans, like the DV-ROF series, are available with horizontal or vertical air discharge and are suitable for industrial, commercial, and residential applications. They are designed to handle high temperatures and provide efficient air movement.
Technical Specifications:
The document provides detailed technical data for duct and roof fans, including dimensions, maximum air temperature, noise levels, airflow, pressure, casing and rotor materials, power consumption, voltage, current, protection class, insulation class, and energy class compliance.
Assembly Systems for Roof Fans:
The document outlines complete systems for roof fan assembly, including roof lead-ins, mounting plates, and pipe stub connectors. These components ensure thermal and acoustic insulation and facilitate easy installation and maintenance.
Overview of DV-REG-L Speed Regulator:
The DV-REG-L electronic speed regulator is designed for smooth motor speed adjustment in one-phase fans with power consumption between 0.25A and 2.5A. It supports both flush-mounted and surface-mounted installations and allows for the connection of multiple fans.
Specifications of DV-REG Speed Regulator:
The DV-REG speed regulator features a back-lit power supply switch and a diode indicating voltage presence on the fan motor winding.
Components:
The document lists components such as the Fan DV-ROF-R, Roof base PDI-BRF, Mounting plate PDI-BRF-PLATE, Flange FLS, and SPIRO duct, which are associated with the installation and operation of the speed regulator.
See more

Catalog excerpts

Overview of fans & accesories - ERP 2015-1

ErP 2015 The ErP Directive New values for fans

 Open the catalog to page 1
Overview of fans & accesories - ERP 2015-2

What is ErP 2015? ErP, that is, ”Energy related Products” means products related to energy. In order to accomplish the objectives of the EU Climate and Energy Package the EuP directive - “Energy-Using Products” was issued in 2005, which was thereafter replaced by the ErP directive in 2009. This directive specifies the rules for setting requirements concerning the energy related products, including electric motors used in fans. The main purpose of the ErP directive is to increase the efficiency of the rotor-fan units by 20%. It also supports the accomplishment of the objectives set in the EU Climate...

 Open the catalog to page 2
Overview of fans & accesories - ERP 2015-3

the air stream, exceeds 65 °C; • when the temperature of the moved air or the ambient temperature during the operation of the motor being outside the air stream are lower than – 40°C; • if the supply voltage exceeds 1000 V in the case of AC power supply or 1500 V in the case of DC power supply; • in the conditions of exposure to toxic, flammable or strongly corrosive agents or in the conditions of exposure to abrasive substances; e) provided with the heat exchanger or thermal pump, serving the purpose of heat recovery or enabling the transfer or heat recovery additionally for the operation of...

 Open the catalog to page 3
Overview of fans & accesories - ERP 2015-4

Duct fans Model: DV-PP-L The DV-PP-L duct fan is used to supply and exhaust the air in ventilation ducts. The DV-PP-L duct fans are an ideal solution for the air exhaust in bathrooms and other rooms. Small sizes of the DV-PP-L fans facilitate the assembly in locations that are hard to access and where the space is limited. Model: DV-PP Intended for general ventilation with the low degree of dusting the round duct fan is characterised by high efficiency at minimum noise level. It can be mounted both in the vertical and horizontal arrangement, and the universal construction enables its maintenance...

 Open the catalog to page 4
Overview of fans & accesories - ERP 2015-5

Roof fans DV-ROF-R 355 ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI Model: DV-ROF-R A+++ A++ A+ The DV-ROF-R roof fan with horizontal air discharge is available in two versions of the winding insulation class - B and F. The DV-ROF roof fan has a broad range of applications: industrial and construction applications, in factories, hospitals, night clubs, theatres, houses, restaurants. The exhaust fans are intended for installation on dampening roof bases. Model: DV-ROF-V DV-ROF-V roof fan with vertical air discharge It is available in two versions of the winding insulation...

 Open the catalog to page 5
Overview of fans & accesories - ERP 2015-6

Technical data of duct fans Dimensions [mm] Casing material Rotor material galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel galvanised steel ALNOR® systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zm

 Open the catalog to page 6
Overview of fans & accesories - ERP 2015-7

recommended ERV speed regulator protection class Insulation class energy class Technical data of duct fans ALNOR® systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.

 Open the catalog to page 7
Overview of fans & accesories - ERP 2015-8

Technical data of roof fans Fan . . of transported level . ,,, , pressure Casing material Rotor material painted steel painted steel painted steel painted steel painted steel painted steel painted steel ALIMOR systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzezone

 Open the catalog to page 8
Overview of fans & accesories - ERP 2015-9

recommended ERV speed regulator protection class Insulation class energy class Technical data of roof fans ALNOR® systemy wentylacji jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.

 Open the catalog to page 9
Overview of fans & accesories - ERP 2015-10

Complete system for roof fan assembly PDI-BRF roof lead-in The roof lead-in fits the BRF/DV-ROF-R fans, which occur in two versions of the winding insulation class B and F. In the case of mounting the fan directly on the lead-in, use the USZ gasket at the location where the fan gets into contact with the lead-in. The roof lead-in can be provided at an angle of 1-60 degrees. Lead-in height - 100 or 500 mm. The lead-in is insulated with wool with the thickness of 30 mm and 50 mm, depending on the size. PDI-BRV roof lead-in The roof lead-in fits the BRV/DV-ROF-V fans, which occur in two versions...

 Open the catalog to page 10
Overview of fans & accesories - ERP 2015-11

Complete system for roof fan assembly SPIRO pipe stub connector for the roof fan It can be mounted only on top of the lead-in (between the lead-in and the fan). While mounting the plate onto the lead-in, use the SIL-DEK-310 roofing sealant at the site where the plate joins the lead-in. From the side where the plate joins the fan, use the USZ gasket to ensure leak-tightness. The lead-in fulfils only the role of the thermal insulation. Straight plate with the ILSL or ILSVL pipe stub connector. DV-REG-L electronic speed regulator The electronic fan speed regulator serves the purpose of smooth adjustment...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.