F-SERIES

F-SERIES
1 / 16 PagesView full catalog

F-SERIES

Product catalog summary
Introduction
ALMATEC air-operated diaphragm pumps are engineered for reliability and safety. Proper usage and adherence to the manual are crucial to avoid damage or injury.
General Description and Use
The F-Series pumps are oscillating positive displacement pumps featuring a double diaphragm design, two liquid chambers, and a pulsation damper. They are designed for liquid transport under specific conditions.
Storage
Pumps should be stored in a ventilated, dust-free environment with temperatures between 15°C and 25°C and humidity below 65%.
Code System and Compliance
ALMATEC pumps comply with DIN EN ISO 9001:2008 and 14001:2005 standards. Ensure compliance with EU machinery directives and suitability for the intended application.
Operation in Explosion-Proof Areas
In explosive environments, use pumps made of conductive plastic materials. Grounding is required, and additional safety measures are necessary when using non-conductive diaphragms.
Technical Data
Specifications include nominal port size, air connection, weight, suction head, operating pressure, temperature, viscosity, and sound pressure levels.
Installation and Start-up
Follow the installation plan for proper setup. Ensure connections are load-free and use pulsation dampers to reduce vibrations. Proper air supply and pressure regulation are crucial for optimal performance.
Safety Hints
Only qualified personnel should handle installation and maintenance. Regular checks and adherence to torque specifications for housing bolts are necessary. Safety measures must be in place to prevent accidental operation.
Maintenance and Troubleshooting
Regular inspection and maintenance are required for safe operation. In case of diaphragm rupture, replace the muffler and check for fluid intrusion into the air supply lines.
Additional Safety Measures
Ensure the pump is not submerged, and avoid chemical reactions or freezing within the pump. Follow proper decontamination procedures when handling hazardous liquids.
Specifications and Safety Guidelines
Secure handling is required to prevent injuries during lifting or assembly. Replace wear parts like diaphragms regularly. Using non-original spare parts or making structural changes voids the warranty. Pumps can operate with nitrogen as a driving gas, but ensure proper ventilation in closed spaces. Electrical connections should be performed by qualified personnel.
Temperature and Pressure Considerations
Temperature and pressure limits are based on the mechanical limits of housing materials. Low temperatures can cause cold-brittling of elastomers. PE and PTFE materials maintain mechanical strength at low temperatures. Avoid freezing or crystallization of fluids within the pump.
Disassembly and Assembly Instructions
Use the provided plastic tool for mounting the air control system. Ensure all sealing surfaces are clean and undamaged. Moisture O-rings before assembly and ensure they are correctly seated. Check pump tightness before operation.
Troubleshooting Guide
Common issues include blocked air supply lines, worn piston rings, and diaphragm ruptures. Solutions involve cleaning or replacing components, ensuring sufficient air supply, and checking for leaks.
Spare Parts and Maintenance
A detailed spare part list is provided for models F 10 and F 20. When ordering spare parts, include the pump's serial number.
Back Sucking System
Optional hand-operated or pneumatical back sucking systems are available for pump size F 20, allowing for reversing the transport direction in the delivery chamber.
Contact Information
ALMATEC Maschinenbau GmbH, Germany. For more information, visit their website or contact via email.
See more

Catalog excerpts

F-SERIES-1

ALMATEC F-Series F 10 / F 20 Operating and Installation Instructions ought to be studied before installing the pump Original Instruction Introduction ALMATEC air-operated diaphragm pumps are constructed according to the state of the art and they are reliable. Imminent danger by operating error or misuse can lead to damages of properties and/or persons. The pumps are to be applied for the intended use and in a safety-related proper condition only. Each person working on the ALMATEC air-operated diaphragm pumps concerning installation, start-up, handling or maintenance has to read this manual completely and in an attentive way and has to follow all mentioned procedures and safety notes. General description of the machine, appropriate use and residual dangers The ALMATEC F-Series pumps are oscillating positive displacement pumps and are based on the functional principle of double diaphragm pumps. The design includes two separated liquid chambers as well as an integrated pulsation damper. The basic configuration consists of two external pump housings with a center housing between them. Each of the side housings contains a product chamber which is sealed against the center housing by a diaphragm. The two diaphragms are interconnected by a piston rod. Directed by an air control system, the diaphragms are alternately loaded with compressed air so that they move back and forth. So the liquid is displaced or drawn in. In addition a pulsation damper smooths the liquid flow in the left product chamber. The appropriate use of an Almatec air-operated diaphragm pump refers to the liquid transport taking into account the operation parameter mentioned in this manual and in compliance of the given terms for commissioning, operation, assembly, disassembly and maintenance. Even if all necessary safety measures described in this manual have been met, a residual danger exists by leakages or mechanical damages. At sealing areas or connections liquid can be released uncontrollably then. Storage In general the ALMATEC pump is delivered operational and packaged. If the unit is not installed right away, proper storage conditions are important for a trouble free operation later. The pump has to be protected from wetness, coldness, dirtying, UV-radiation and mechanical influences. The following storage conditions are recommended: - Steady ventilated, dust and vibration free storage room - Ambient temperature between 15°C and 25°C with a relative humidity below 65% - Prevention of direct thermal influences (sun, heating) 1

 Open the catalog to page 1
F-SERIES-2

Code system The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise according to DIN EN ISO 9001:2008 and 14001:2005. Before release for dispatch, any pump has to undergo an extended final control. As a general rule in the countries of the EU only such machines are allowed to take into operation, which are determined to meet the regulations of the EU machinery directive, the harmonized standards, European standards and the respective national standards. Hence the operator has to verify whether the ALMATEC pump manufactured and delivered properly according to the...

 Open the catalog to page 2
F-SERIES-3

Installation and Start-up The correct installation procedure is based on the „Dimensions and connection plan ALMATEC F 10 and F 20“ on page 7. ALMATEC pumps of the F-Series are pneumatic diaphragm pumps with integrated pulsation damper and two separated product chambers. air supply suction delivery chamber discharge extractor resp. circulation chamber discharge extractor resp. circulation chamber alternative suction extractor resp. circulation chamber discharge delivery chamber The actual transport of the liquid is realized by the delivery chamber. To smoothen the flow, the fluid passes an active...

 Open the catalog to page 3
F-SERIES-4

The operator is responsible for an adequately stability and an appropriate fixation of the piping according to the state of the art. To facilitate the installation and maintenance shut off valves should be installed right before and after the pump. The nominal width of the connection pipes has to be chosen in accordance to the connections of the pump. A smaller piping can cause cavitations (suction line) as well as a loss of performance (suction and discharge line). In case the pipe is too big, the dry suction capacity of the pump can decrease. Seal the suction line diligently; hosepipes should...

 Open the catalog to page 4
F-SERIES-5

„h Pressure tests of the plant a pump is included in may only be d isconnected from the pressure on both ports or by using the pressure the pump develops while operating. The load of a pressure in the plant may damage the pump. „h Pump must not be operated with a positive suction pressure. „h Depending on the conditions of opera t hrough the muffler in case of a diaphragm rupture (in this case muffler has to be replaced). For further safety requirements the optional equipment diaphragm monitoring and barrier chamber system are recommended. „h In case of a diaphragm rupture, it might be possible...

 Open the catalog to page 5
F-SERIES-6

Additional temperature hints The temperature and pressure limitations listed on page 2 are solely based on mechanical temperature limits of the housing material used. Depending on the fluid pumped, the maximum safe operating temperature of the housing material can be reduced significantly. A general aspect of lower temperatures is, that below 0°C cold-brittling of the elastomers used within the pumps can results in accelerated wear. Regarding the housing materials, please note that PE - other than PP - keeps its mechanical strengths at low temperatures and PTFE keeps mechanically stable as well...

 Open the catalog to page 6
F-SERIES-7

Dimensions and connection plan 7

 Open the catalog to page 7
F-SERIES-8

Troubleshooting Malfunction Possible Reason Solutions/Remarks pump does not operate air supply line blocked/closed muffler blocked working chambers blocked air control system defective discharge line blocked/closed open air supply clean/replace muffler remove blockage replace air valve system clean/open line pump operates unsteadily piston rings worn air control system worn diaphragm rupture air control system soiled check valve blocked icing replace piston rings replace air control system replace diaphragm, clean pump clean/replace air control system cleaning, removal of bulk particles improve...

 Open the catalog to page 8

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.