Terminal Blocks/Wiring Systems/Signal Conditioners • DIN Mounting Rails Page 12-79 • Partition Plates Page 12-82 • Test Plugs Page 12-87 • General Accessories Page 12-89 • Marking Systems Page 12-90 NEMA/EEMAC Terminal Blocks • Open Construction Blocks Page 12-102 • Isolation Switch Blocks Web}: • Voltage Indicating Blocks Web} Panel Mount Blocks NEMA Accessories and Technical • Mounting Rails Page 12-109 • Stacking Bridge Kits Page 12-110 • Side Jumpers/Fanning Strips Page 12-111 • Fuse Puller/Test Sockets Page 12-112 • Marking Systems Page 12-113 Power Blocks Programmable Controller...
Open the catalog to page 2Overview and Regulatory Information Allen-Bradley terminal blocks generally have been designed to meet the requirements of one or more regulatory bodies. Most products have also been tested per additional standards. The following is a listing of some of the regulatory bodies and standards which apply to Allen-Bradley terminal block products. See the particular product description for information on specific certifications and ratings. (Underwriters Laboratories) — Devices in this catalog with one of these ratings have been tested by Underwriters Laboratories and meet the requirements of one...
Open the catalog to page 3Bulletin 1492 Screw Connection Terminal Blocks Certifications/Introduction 0 Ex e II — Many 1492-J, 1492-K, 1492-L, and 1492-W terminal blocks in this catalog meet the following Canadian Standards per Underwriters Laboratories: CAN/CSA E 60079-7 — Electrical Apparatus for Explosive Atmospheres — Part 0 — General Requirements CAN/CSA E 60079-0 — Electrical Apparatus for Explosive Atmospheres — Part 7 — Increased Safety “e” These products are suitable for Class I, Zone 1 Hazardous Locations. Reference UL file E187022. Contact your local Allen-Bradley distributor for more information. 1 2 3 4...
Open the catalog to page 4Screw Connection Terminal Blocks Tie-Point Block Incorporates a shunt bar between the upper and lower current bars to provide a common point among all four terminals. Diode Block Uses a 1N4007 diode between the upper and lower levels for insertion into a control circuit. This block is useful in low voltage DC control circuits for Surge Suppression Block (Cat. No. 1492-JD3SS) Resistor Block Provides a convenient means of incorporating transient Permits the introduction of a 10 O...4.75 MO resistor into a control circuit. suppression for relays, contactors, and solenoids into a control •...
Open the catalog to page 5Screw Connection Terminal Blocks Mini Blocks www.ab.com/catalogs Preferred availability cat. nos. are bold. £t\ Allan RtSittlpif
Open the catalog to page 6Screw Connection Terminal Blocks Mini Blocks fifo Allan RfoHlatf www.ab.com/catalogs Preferred availability cat. nos. are bold. ^HBT HIIUll-DlaUICy Publication A117-CA001A-EN-P 12-7
Open the catalog to page 7Screw Connection Terminal Blocks Standard Feed-Through Blocks used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal Feed-through terminal block Feed-through terminal block Feed-through terminal block Voltage Rating Maximum Current Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Housing Temperature Range Short-Circuit Current Rating * Use of center jumpers may affect spacings, requiring derating of terminal blocks. See page 12-83 for details. www.ab.com/catalogs Preferred availability cat. nos. are bold.
Open the catalog to page 8Screw Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used Note: Height dimension is measured from top of rail to top of terminal Feed-through terminal block Feed-through terminal block Feed-through terminal block Voltage Rating Maximum Current Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Housing Temperature Range Short-Circuit Current Rating ffit\ Allan Rrstfilair www.ab.com/catalogs Preferred availability cat. nos. are bold.
Open the catalog to page 9Screw Connection Terminal Blocks Standard Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rai Feed-through terminal block Feed-through terminal block Feed-through terminal block Voltage Rating Maximum Current Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Housing Temperature Range Short-Circuit Current Rating Auxiliary connection, allowing a single additional #26...8 AWG wire connection. www.ab.com/catalogs Preferred availability cat. nos. are bold. £t\ Allan RtSittlpif
Open the catalog to page 10Screw Connection Terminal Blocks Space-Saver Feed-Through Blocks Dimensions are not intended to be used Note: Height dimension is measured from top of rail to top of terminal Single-circuit terminal block. Single-circuit terminal block. Single-circuit terminal block. Voltage Rating Maximum Current Wire Range (Rated Cross Section) Wire Strip Length Recommended Tightening Torque Housing Temperature Range Terminal Blocks Mounting Rails: 1 m Angled Hi-Rise Sym. DIN (Steel) DIN Rail — Normal Duty DIN Rail — Heavy Duty Insulated Side Jumper Center Jumper Link Center Jumper Cover — White Other...
Open the catalog to page 11Screw Connection Terminal Blocks Space-Saver Feed-Through Blocks www.ab.com/catalogs Preferred availability cat. nos. are bold. £t\ Allan RtSittlpif
Open the catalog to page 12Screw Connection Terminal Blocks Multi-Circuit Feed-Through Blocks * Screw Center Jumpers, $ Plug-in Center Jumpers fifo Allan RfoHlatf www.ab.com/catalogs Preferred availability cat. nos. are bold.
Open the catalog to page 13Screw Connection Terminal Blocks Specialty Feed-Through Blocks Dimensions are not intended to be used for manufacturing purposes. Note: Height dimension is measured from top of rail to top of terminal block. Feed-through terminal block with 2 connection points on each side Feed-through terminal block with 3 connection Feed-through terminal block with 3 connection points, 2 on one side Voltage Rating Maximum Current Single Side Twin Side Wire Range (Rated Cross Single Side Twin Side Wire Strip Length Recommended Tightening Torque Single Side: 7.0 lb«in (0.8 N«m) nsulation Temperature Current...
Open the catalog to page 14All Allen Bradley catalogs and technical brochures
-
SENSOR-BR001
9 Pages
-
IA-BR005
64 Pages
-
937-SG001
70 Pages
-
937-PP001
4 Pages
-
931-TD001
52 Pages
-
931-AT001
2 Pages
-
931-AT002
4 Pages
-
Disconnect Switches
7 Pages
-
Encompass Partner - Stahlin
4 Pages
-
Encompass Partner - WIN-911
4 Pages
-
2014 Encompass Product
19 Pages
-
Essential Components
358 Pages
-
Operator Interface
54 Pages
-
RFID
20 Pages
-
DeviceNet Sensors
18 Pages
-
Network Media
14 Pages
-
Connection Systems
46 Pages
-
Encoders
56 Pages
-
Capacitive Proximity Sensors
22 Pages
-
Ultrasonic Sensors
16 Pages
-
Inductive Proximity Sensors
233 Pages
-
Photoelectric Sensors
334 Pages
-
Limit Switches
143 Pages
-
Safety Switches
160 Pages
-
Lighting Control
26 Pages
-
Push Buttons
226 Pages
-
Motor control centers
262 Pages
Archived catalogs
-
Motors
256 Pages
-
CENTERLINE® Motor Control Centers
266 Pages
-
Motor Control Centers
42 Pages
-
Safety Isolation System
20 Pages
-
Applied Safety Solutions
10 Pages