ACS716

ACS716
1 / 22 PagesView full catalog

ACS716

Product catalog summary
Introduction: The document provides a comprehensive overview of the Allegro ACS716 current sensor, highlighting its design for precise current sensing in various systems. It integrates a precision linear Hall sensor with a copper conduction path, ensuring high accuracy and low output ripple.
Features and Benefits: The ACS716 offers industry-leading noise performance and improved bandwidth due to its proprietary amplifier and filter design. It features a low primary conductor resistance of 1 mΩ, high isolation voltage, and a user-adjustable overcurrent fault level with a rapid response time of less than 2 μs.
Specifications: Operating on a 3 to 3.6 V supply, the ACS716 has a nominal voltage of 3.3 V, a 120 kHz bandwidth, and high voltage isolation. It is available in models with varying current sensing ranges and sensitivity levels.
Applications: The sensor is suitable for motor control, load management, overcurrent detection, power conversion, and battery monitoring/UPS systems.
Isolation and Ratings: The ACS716 features a dielectric strength test voltage of 3000 VAC and a working voltage for basic isolation of 277 VAC, operating within a temperature range of -40°C to 125°C.
Pin Configuration: Available in latching and non-latching versions, the sensor comes in a 16-pin SOIC package with key pins for current sensing and overcurrent fault threshold setting.
Performance Characteristics: The sensor offers a full range linearity of ±0.25%, a signal rise time of 3 μs, and a propagation time of 1 μs. It includes specific characteristics for different models, such as the X6BB, X12CB, and X25CB, each with distinct accuracy ranges and sensitivity levels.
Overcurrent Fault Management: The document details the calculation of the overcurrent fault switchpoint voltage and the role of external capacitors in managing fault detection delay.
Graphical Data: Graphs illustrate relationships between parameters like electrical offset voltage, nonlinearity, sensitivity, and total output error versus ambient temperature.
Conclusion: The ACS716 sensor is designed for high accuracy and reliability in overcurrent detection, with configurations for various current ranges. The document supports its integration into applications requiring precise current monitoring and fault detection.
Additional Features: The document also covers fault management, chopper stabilization techniques to minimize offset voltage, and dynamic response characteristics such as propagation delay and rise time.
Package and Revision History: It includes a reference layout for the 16-pin SOICW package and notes on updates to terminology and product versions.
See more

Catalog excerpts

ACS716-1

ACS716 120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection Features and Benefits ▪ Industry-leading noise performance with greatly improved bandwidth through proprietary amplifier and filter design techniques ▪ Small footprint package suitable for space-constrained applications ▪ 1 mΩ primary conductor resistance for low power loss ▪ High isolation voltage, suitable for line-powered applications ▪ User-adjustable Overcurrent Fault level ▪ Overcurrent Fault signal typically responds to an overcurrent condition in < 2 μs ▪ Integrated shield virtually eliminates capacitive coupling from current conductor to die due to high dV/dt voltage transients ▪ Filter pin capacitor improves resolution in low bandwidth applications ▪ 3 to 3.6 V, single supply operation ▪ Factory trimmed sensitivity and quiescent output voltage ▪ Chopper stabilization results in extremely stable quiescent output voltage ▪ Ratiometric output from supply voltage The Allegro™ ACS716 current sensor provides economical and precise means for current sensing applications in industrial, commercial, and communications systems. The device is offered in a small footprint surface mount package that allows easy implementation in customer applications. Package: 16-pin SOIC Hall Effect IC Package (suffix LA) The ACS716 consists of a precision linear Hall sensor integrated circuit with a copper conduction path located near the surface of the silicon die. Applied current flows through the copper conduction path, and the analog output voltage from the Hall sensor linearly tracks the magnetic field generated by the applied current. The accuracy of the ACS716 is maximized with this patented packaging configuration because the Hall element is situated in extremely close proximity to the current to be measured. High level immunity to current conductor dV/dt and stray electric fields, offered by Allegro proprietary integrated shield technology, results in low ripple on the output and low offset drift in high-side, high voltage applications. The voltage on the Overcurrent Input (VOC pin) allows customers to define an overcurrent fault threshold for the device. When the current flowing through the copper conduction path (between the IP+ and IP– pins) exceeds this threshold, the open drain Overcurrent Fault pin will transition to a logic low state. Factory programming of the linear Hall sensor inside of the ACS716 results in exceptional accuracy in both analog and digital output signals. The internal resistance of the copper path used for current sensing is typically 1 mΩ, for low power loss. Also, the current conduction path is electrically isolated from the low voltage Continued on the next page… Noise and bandwidth limiting filter capacitor Fault delay setting capacitor, 22 nF maximum Use of resistor optional, 330 kΩ recommended. If used, resistor must be connected between ¯ ¯¯¯ ¯ pin and VCC. ¯ L¯ ¯ FAU¯ T Sets resistor divider reference for VOC

 Open the catalog to page 1
ACS716-2

120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection Description (continued) sensor inputs and outputs. This allows the ACS716 family of sensors to be used in applications requiring electrical isolation, without the use of opto-isolators or other costly isolation techniques. Pb-based solder balls, currently exempt from RoHS. The device is fully calibrated prior to shipment from the factory. The ACS716 is provided in a small, surface mount SOIC16 package. The leadframe is plated with 100% matte tin, which is compatible with standard lead (Pb) free printed...

 Open the catalog to page 2
ACS716-3

120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection Absolute Maximum Ratings Characteristic Supply Voltage Fault Enable (FAULT_EN) Pin Voltage Reference Output Pin DC Reverse Voltage: VCC, FILTER, VIOUT, VOC, ¯ ¯¯¯ ¯ , FAULT_EN, and VZCR Pins ¯ L¯ ¯ FAU¯ T Excess to Supply Voltage: FILTER, VIOUT, VOC, ¯ ¯¯¯ ¯ , FAULT_EN, and VZCR Pins ¯ L¯ ¯ FAU¯ T Output Current Source Voltage by which pin voltage can exceed the VCC pin voltage Output Current Sink Operating Ambient Temperature Junction Temperature Storage Temperature Isolation Characteristics Characteristic...

 Open the catalog to page 3
ACS716-4

120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection Functional Block Diagram Latching Versions VCC Hall Bias Fault Latch FAULT Reset Drain Control Logic Fault Comparator – Sensitivity Trim Signal Recovery Hall Amplifier Terminal List Table, Latching Versions Number Sensed current copper conduction path pins. Terminals for current being sensed; fused internally, loop to IP– pins; unidirectional or bidirectional current flow. Sensed current copper conduction path pins. Terminals for current being sensed; fused internally, loop to IP+ pins; unidirectional...

 Open the catalog to page 4
ACS716-5

120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection Functional Block Diagram Non-Latching Versions VCC Hall Bias FAULT Reset 3 mA OC Fault VZCR Fault Comparator Signal Recovery Hall Amplifier Terminal List Table, Non-Latching Version Number Sensed current copper conduction path pins. Terminals for current being sensed; fused internally, loop to IP– pins; unidirectional or bidirectional current flow. Sensed current copper conduction path pins. Terminals for current being sensed; fused internally, loop to IP+ pins; unidirectional or bidirectional current...

 Open the catalog to page 5
ACS716-6

120 kHz Bandwidth, High Voltage Isolation Current Sensor with Integrated Overcurrent Detection COMMON OPERATING CHARACTERISTICS Valid at TA = –40°C to 125°C, VCC = 3.3 V, unless otherwise specified Characteristic ELECTRICAL CHARACTERISTICS Supply Voltage Nominal Supply Voltage Supply Current Output Capacitance Load Output Resistive Load Magnetic Coupling from Device Conductor to Hall Element Internal Filter Resistance1 Test Conditions ¯ L¯ ¯ VIOUT open, ¯ ¯¯¯ ¯ pin high FAU¯ T VIOUT pin to GND VIOUT pin to GND Current flowing from IP+ to IP– pins VCC VCCN ICC CLOAD RLOAD MCHALL Primary Conductor...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.