I Pump PRESENTATION AND INFORMATION BOOKLET OF MONOPUMP HAS-ER Solution partner for pumping of difficult fluids...

Open the catalog to page 1
Transfer Pumps - 2

Solution partner for pumping of difficult fluids…

Open the catalog to page 2
Transfer Pumps - 3

Monopump (positive displacement pump), It is used to transfer fluid and semi-fluid products with high viscosity values. It does not unmake the properties of the transferred liquid, and ensures the transfer of products without problems such as foaming, separation and fragmentation. Working different capacity and pressure such as 5 liter /hour and 200 m3/ hour @0-24 bar pumps in the range are produced in our company. Trouble-free operation temperature values -30 C° up to 250 C° It works silently and without vibration, it can work without any problems in open or closed areas by providing...

Open the catalog to page 3
Transfer Pumps - 4

Solution partner for pumping of difficult fluids… WORKING PRINCIPLE OF MONOPUMP 1. Rotor As indicated in the cross-section picture above, part 1 is called ROTOR, part number 2 is called STATOR. The rotor shaft moves 360° inside the stator housing with the movement it receives from the electric motor. The product in the pump is transported to the cavities with the vacuum and compression created by this movement. Thus, the transferred product is transferred to the outlet pipeline under pressure. Since the stator has a rubber structure, it is resistant to flexing and deformation

Open the catalog to page 4
Transfer Pumps - 5

Solution partner for pumping of difficult fluids… High suction and high performance (Maximum 8 meters) Model range of maximum 200 m3/h and 24 BAR Pump inlet option according to installation cond. (Right - Left - Vertical connection) Different sealing solutions (Mechanical – Soft) Optional stainless steel or other alloy steel variants Different rubber options (EPDM, NBR, NR, Viton) Optional wash inlet drains

Open the catalog to page 5
Transfer Pumps - 6

Solution partner for pumping of difficult fluids… It is preferred for the transfer of high-density products. High performance Max. 50 m3/h and 18 BAR model range Transferring products containing solid particles Product can collect with conical feeding Material continuity with the feeding auger Gapless product transfer Different sealing solutions (Mechanical – Soft) Optional wash inlet drains Optional stainless steel or other alloy steel variants Different rubber options (EPDM, NBR, NR, Viton)

Open the catalog to page 6
Transfer Pumps - 7

Solution partner for pumping of difficult fluids... It is preferred for the transfer of high-density products. Product can collect with conical feeding Material continuity with the feeding auger Gapless products transfer Transfer of products with high dry matter content Different sealing solutions (Mechanical and Soft) Optional wash inlet drains Optional stainless steel or other alloy steel variants Different rubber options (EPDM, NBR, NR, Viton) www.industrialtransferpump.com Q +90 532 304 52 65 ( Wha tsapp) info@industrialtransferpurrb.com

Open the catalog to page 7
Transfer Pumps - 8

Solution partner for pumping of difficult fluids… Suction feature max 4 meters High performance Max. 30 m3/h and 24 bar model range Fork hoint option for hygienic pumps Pump inlet option according to installation cond. ( Right-Left or Vertical Connection) Different sealing solutions (Mechanical – Soft) Optional wash inlet drains Optionally heating and cooling jackets ( Wall ) Optional stainless steel or other alloy steel variants Different rubber options (EPDM, NBR, NR, Viton)

Open the catalog to page 8
Transfer Pumps - 9

Solution partner for pumping of difficult fluids… Emiş özelliği Maksimum 4 metre High performance max. 4 m3/h and 24 bar model range High compressive strength since the flange connection Pump inlet option according to installation cond. ( Right-Left or Vertical Connection) Different rubber options (EPDM, NBR, NR, Viton)

Open the catalog to page 9
Transfer Pumps - 10

Solution partner for pumping of difficult fluids…

Open the catalog to page 10
Transfer Pumps - 12

MONOPUMPS HAS-ER Solution partner for pumping of difficult fluids...

Open the catalog to page 12
Transfer Pumps - 13

Solution partner for pumping of difficult fluids… SPARE PARTS OF MONOPUMPS

Open the catalog to page 13
Transfer Pumps - 14

THINGS TO CONSIDER WHEN USING THE MONOPUMP The pump should never be run dry. The pump must be equipped with a suitable dry-running protection device. The dry-running protection device must be self-monitoring. The pump should not be pressurized beyond the safety limit. The pump must be equipped with a suitable high-pressure safety device. The pump must not press against the closed point. Solution partner for pumping of difficult fluids… USER MANUAL The drives must match the power of the pump. In the event of the pump jamming, the drives must automatically switch off via the motor protection....

Open the catalog to page 14
Transfer Pumps - 15

THINGS TO CONSIDER WHEN USING THE MONOPUMP Check that there is no crushing or damage anywhere on the shipped pump. Make the electrical connections of the pump with an electrician. Solution partner for pumping of difficult fluids… USER MANUAL Check that the direction of rotation of the pump is correct. (If it is in the direction of the arrow, it is connected correctly.) Before starting the pump, which is connected to the electricity, make sure that the ground connection bolts are attached. Make sure that the ground on which the machine will operate is flat. Make the adjustment of the chassis...

Open the catalog to page 15
Transfer Pumps - 16

STATOR REPLACEMENT HAS-ER Solution partner for pumping of difficult fluids... Make sure electric is not connected. Unscrew the stud nuts (1). Remove the bolts that secure the front foot to the chassis. (5) Separate the front feet from the pump. (2) Remove the studs from the pump. (3) Remove the coupling shield. (6) Tighten the coupling with a pipe wrench or chain wrench to prevent it from turning.(7) After tightening the coupling, remove the stator by pulling it from one side and turning it from the other side.(4) You can install another stator in the same way to attach it to the pump.

Open the catalog to page 16
Transfer Pumps - 17

Solution partner for pumping of difficult fluids… USER MANUAL R OT OR REP LAC EMENT To remove the rotor, first remove the stator. (3) After removing the stator, remove the chamber connection bolts. (1) Remove the chamber from the pump by pulling in the direction of the arrow. (2)

Open the catalog to page 17
Transfer Pumps - 18

Solution partner for pumping of difficult fluids… USER MANUAL After the chamber has been removed from the pump, remove the circlip using a ring pliers. (1) Remove the head bushing.(2) Remove the rotor pim. (3) Disconnect the rotor from the pump. (4) To install a new rotor on the pump, you can reverse the same steps.