Product catalog summary
Overview: The document provides technical specifications for the CODA KCO-Series Mass Flow Controllers, which handle flow rates from 40 to 100,000 grams per hour. It includes details on mechanical, sensor, control performance, communications, and range-specific technical data.
Mechanical Specifications: The operating temperature range is 0–60°C for ambient and −35–70°C for fluid. The ingress protection is either IP40 or IP67. Wetted materials include 316L stainless steel, FKM & FFKM, with options for EPDM or PCTFE.
Sensor and Control Performance: Mass flow accuracy is ±0.6% for liquids and ±1% for gases. The repeatability is ±0.1% of full scale, with a steady state control range of 5%–100% of full scale. Density accuracy is ±5 kg/m³, and the measurable density range is 100–2,000 kg/m³. The viscosity range is 0–200 cP.
Communications: The controllers offer analog I/O options (0–5 Vdc, 0–10 Vdc, 4–20 mA) and digital I/O options (Serial and Modbus RTU over RS-232 or RS-485, EtherCAT, EtherNet/IP). Electrical connections include USB-C, DB-15, M12, and RJ45.
Range-Specific Technical Data: The document details process connections, recommended inlet filters, nominal pressure drop, and proof pressure for different flow ranges. For example, a 40 g/h flow uses a 1/4″ VCR®-compatible male connection with a 2 μm filter and ≥6 PSID pressure drop.
Dimensions and Weight: Dimensions vary based on flow scale, with the 40–10,000 g/h models measuring approximately 4.318 in height and weighing about 2.0 lb. The 30,000–100,000 g/h models are larger and heavier.
See more

Catalog excerpts

DOC-SPECS-KCO · REV 1, 10 May 2021 1   ⁄   2Technical Data for CODA KCO-Series Mass Flow Controllers-1

Technical Data for CODA KCO-Series Mass Flow Controllers 40 to 100,000 grams per hour full scale Standard specifications. Consult Alicat for available options. SENSOR AND CONTROL PERFORMANCE Liquid: ±0.6% of reading or ±0.2% of full scale, whichever is greater Gas: ±1% of reading or ±0.2% of full scale, whichever is greater Mass Flow Accuracy Repeatability Steady State Control Range Measurable Density Range Viscosity Range Zero Stability ±0.2% of full scale (included in mass flow accuracy) Mass flow zero shift: ±0.02% of full scale per °C from tare temperature2 Mass flow span shift: ±0.01% of reading per °C from 25°C Temperature Sensitivity Valve Function Normally Closed Typical Control Response Time Typical Indication Response Time 1 Density reading and density accuracy are independent of the mass flow reading and mass flow accuracy. 2 Mass flow zero shift for 40 g/h is ±0.025% of full scale per °C from tare temperature. MECHANICAL Ambient: 0–60°C Fluid: −35–70°C Consult Alicat for additional options Operating Temperature Range Ingress Protection Wetted Materials 316L stainless steel, FKM & FFKM standard; EPDM or PCTFE optional Consult Alicat for additional wetted materials options COMMUNICATIONS Analog I/O Options Serial and Modbus RTU over RS-232 or RS-485 (default) EtherCAT, EtherNet/IP USB-C and DB-15 (default) M12 (IP rated models) RJ45 (Ethernet equipped models) Electrical Connection Options Power Requirements Digital Update Rate Analog Update Rate RANGE-SPECIFIC TECHNICAL DATA Process connections Recommended inlet filter Full scale flow (g/h) Nominal pressure drop (H₂0) Proof Pressure (PSIA)³ Mounting Options

 Open the catalog to page 1
DOC-SPECS-KCO · REV 1, 10 May 2021 1   ⁄   2Technical Data for CODA KCO-Series Mass Flow Controllers-2

Technical Data for CODA KCO-Series Mass Flow Controllers 40 to 100,000 grams per hour full scale Standard specifications. Consult Alicat for available options. Tare Button Power Light Outlet Port Tapped Mounting Holes DIMENSIONS Full Scale Flow 40–10,000 g/h 30,000– 100,000 g/h

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.